Jim Hansen

Jim Hansen

Auto-generated profile, based on publicly available information

Jim Hansen

Department of Cardiology, Gentofte Hospital , Hellerup

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
BSBoris Schmidt
Boris Schmidt
SBStefano Bordignon
Stefano Bordignon
KNKars Neven
Kars Neven
TRTobias Reichlin
Tobias Reichlin
YBYuri Blaauw
Yuri Blaauw
KCKyoung Ryul Julian Chun
Kyoung Ryul Julian Chun
Aims: Pulsed field ablation (PFA) is a new, non-thermal ablation modality for pulmonary vein (PV) isolation in patients with atrial fibrillation (AF). The multi-centre EUropean Real World Outcomes with Pulsed Field AblatiOn in Patients with Symptomatic AtRIAl Fibrillation (EU-PORIA) registry sought to determine the safety, efficacy, and learning curve characteristics for the pentaspline, multi-electrode PFA catheter. Methods and results: All-comer AF patients from seven high-volume centres were consecutively enrolled. Procedural and follow-up data were collected. Learning curve effects were analysed by operator ablation experience and primary ablation modality. In total, 1233 patients (61% male, mean age 66 ± 11years, 60% paroxysmal AF) were treated by 42 operators. In 169 patients (14%), additional lesions outside the PVs were performed, most commonly at the posterior wall (n = 127). Median procedure and fluoroscopy times were 58 (interquartile range: 40–87) and 14 (9–21) min, respectively, with no differences due to operator experience. Major complications occurred in 21/1233 procedures (1.7%) including pericardial tamponade (14; 1.1%) and transient ischaemic attack or stroke (n = 7; 0.6%), of which one was fatal. Prior cryoballoon users had less complication. At a median follow-up of 365 (323–386) days, the Kaplan–Meier estimate of arrhythmia-free survival was 74% (80% for paroxysmal and 66% for persistent AF). Freedom from arrhythmia was not influenced by operator experience. In 149 (12%) patients, a repeat procedure was performed due to AF recurrence and 418/584 (72%) PVs were durably isolated. Conclusion: The EU-PORIA registry demonstrates a high single-procedure success rate with an excellent safety profile and short procedure times in a real-world, all-comer AF patient population.

17 January 2025 in EP Europace
Verified
Journal Article
Open access
USUniv.-Prof. Priv.-Doz. Dr.med.univ. Daniel Scherr
Univ.-Prof. Priv.-Doz. Dr.med.univ. Daniel Scherr
MTMohit K Turagam
Mohit K Turagam
PMPhilippe Maury
Philippe Maury
YBYuri Blaauw
Yuri Blaauw
PVPepijn van der Voort
Pepijn van der Voort
VRVivek Y Reddy
Vivek Y Reddy
Aims: Initial clinical studies of pulsed field ablation (PFA) to treat atrial fibrillation (AF) indicated a >90% durability rate of pulmonary vein isolation (PVI). However, these studies were largely conducted in single centres and involved a limited number of operators. We aimed to describe the electrophysiological findings and outcomes in patients undergoing repeat ablation after an initial PF ablation for AF. Methods and results: In the MANIFEST-REDO study, we investigated patients who underwent repeat ablation due to clinical recurrence—AF or atrial tachycardia (AT)—following first-ever PVI with a pentaspline PFA catheter (Farawave, Boston Scientific Inc.). At 22 centres, 427 patients (age 64 ± 11 years; 37% female) were included. Of note, the recurrent arrhythmia leading to the repeat ablation was paroxysmal AF (51%), persistent AF (30%), or AT (19%). At the repeat procedure, the PV reconnection rates were 30% (left superior pulmonary vein), 28% (left inferior pulmonary vein), 33% (right superior pulmonary vein), and 32% (right inferior pulmonary vein). In 45% of patients, all PVs were durably isolated at the beginning of the repeat procedure, with the previous use of any imaging or mapping modality being univariately associated with durable PVI. After a post-redo follow-up period of 284 (90–366) days, the primary effectiveness endpoint (freedom from documented AF/AT lasting ≥30 s after 3-month blanking without class I/III antiarrhythmic drugs or symptoms) was achieved in 65% of patients, with significant differences between groups (PAF 65% vs. PersAF 56% vs. AT 76%; P = 0.04). Persistent AF as recurrent arrhythmia after the initial PFA ablation predicted AT/AF recurrence after repeat ablation [hazard ratio 1.241 (95% confidence interval 1.534–1.005); P = 0.045]. The procedural complication rate was 2.8%. Conclusion: In repeat procedures for AF/AT performed after an index procedure with PFA for AF, PV reconnections are not uncommon. Repeat procedures can be performed safely and with an acceptable subsequent success rate.

1 May 2021 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
PDF file
SSSamuel K. Sørensen
Samuel K. Sørensen
AJArne Johannessen
Arne Johannessen
RWRené Worck
René Worck
MHMorten L. Hansen
Morten L. Hansen
JHJim Hansen
Jim Hansen
Background: Recurrent paroxysmal atrial fibrillation (AF) after catheter ablation is presumably caused by failure to achieve durable pulmonary vein isolation (PVI). The primary methods of PVI are radiofrequency catheter ablation (RF) and cryoballoon catheter ablation (CRYO), but these methods have not been directly compared with respect to PVI durability and the effect thereof on AF burden (% of time in AF). Methods: Accordingly, we performed a randomized trial including 98 patients (68% male, 61 [55–67] years) with paroxysmal AF assigned 1:1 to PVI by contact-force sensing, irrigated radiofrequency catheter, or second-generation cryoballoon catheter. Implantable cardiac monitors were inserted ≥1 month before PVI for assessment of AF burden and recurrence, and all patients, irrespective of AF recurrence, underwent a second procedure 4 to 6 months after PVI to determine PVI durability. Results: In the second procedure, 152 out of 199 (76%) pulmonary veins (PVs) were found durably isolated after RF and 161 out of 200 (81%) after CRYO ( P =0.32), corresponding to durable isolation of all veins in 47% of patients in both groups ( P =1.0). Median AF burden before PVI was 5.4% (interquartile range, 0.5%–13.0%) versus 4.0% (0.6%–18.1%), RF versus CRYO ( P =0.71), and reduced to 0.0% (0.0%–0.1%) and 0.0% (0.0%–0.5%), respectively ( P =0.58)—a reduction of 99.9% (92.9%–100.0%) and 99.3% (85.9%–100.0%; P =0.36). AF burden after PVI significantly correlated to the number of durably isolated PVs ( P <0.01), but 9 out of 45 (20%) patients with durable isolation of all veins had recurrence of AF within 4 to 6 months after PVI (excluding a 3-month blanking period). Conclusions: PVI by RF and CRYO produce similar moderate to high PVI durability. Both treatments lead to marked reductions in AF burden, which is related to the number of durably isolated PVs. However, for one-fifth of paroxysmal AF patients, complete and durable PVI was not sufficient to prevent even short-term AF recurrence. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03805555.

22 February 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
AMAndreas Metzner
Andreas Metzner
MFMartin Fiala
Martin Fiala
JVJohan Vijgen
Johan Vijgen
AOAlexandre Ouss
Alexandre Ouss
MGMelanie A. Gunawardene
Melanie A. Gunawardene
PNPetr Neuzil
Petr Neuzil
Pulmonary vein isolation (PVI) is a well-established strategy for the treatment of paroxysmal atrial fibrillation (PAF). Despite randomized controlled trials and real-world data showing the promise of pulsed-field ablation (PFA) for this treatment, long-term efficacy and safety data demonstrating single-procedure outcomes off antiarrhythmic drugs remain limited. The aim of the FARA-Freedom Study was to evaluate the long-term efficacy and safety of PFA using the pentaspline catheter for PAF. FARA-Freedom, a prospective, non-randomized, multicentre study, enrolled patients with PAF undergoing de novo PVI with PFA, who were followed for 12 months with weekly transtelephonic monitoring and a 72-h Holter ECG at 6 and 12 months. The primary safety endpoint was a composite of device- or procedure-related serious adverse events out to 7 days post-ablation and PV stenosis or atrioesophageal (AE) fistula out to 12 months. Treatment success is a composite of acute PVI and chronic success, which includes freedom from any documented atrial tachyarrhythmia longer than 30 s, use of antiarrhythmic drugs or cardioversion after a 3-month blanking period, or use of amiodarone or repeat ablation at any time. The study enrolled 179 PAF patients (62 ± 10 years, 39% female) at 13 centres. At the index procedure, all PVs were successfully isolated with the pentaspline PFA catheter. Procedure and left atrial dwell times, with a 20-min waiting period, were 71.9 ± 17.6 and 41.0 ± 13.3 min, respectively. Fluoroscopy time was 11.5 ± 7.4 min. Notably, monitoring compliance was high, with 88.4 and 90.3% with weekly events and 72-h Holter monitors, respectively. Freedom from the composite primary effectiveness endpoint was 66.6%, and 41 patients had atrial tachyarrhythmia recurrence, mostly recurrent atrial fibrillation (31 patients). The composite safety endpoint occurred in two patients (1.1%), one tamponade and one transient ischaemic attack. There was no coronary spasm, PV stenosis, or AE fistula. There were four cases of transient phrenic nerve palsy, but all resolved during the index procedure. In this prospective, non-randomized, multicentre study, PVI using a pentaspline PFA catheter was effective in treating PAF patients despite rigourous endpoint definitions and high monitoring compliance and demonstrated favourable safety. Clinical Trials.gov Identifier: NCT05072964 (sponsor: Boston Scientific Corporation).

8 December 2022 in EP Europace
Verified
Journal Article
Open access
PDF file
JTJacob Tønnesen
Jacob Tønnesen
JPJannik Pallisgaard
Jannik Pallisgaard
MRMartin H Ruwald
Martin H Ruwald
PRPeter Vibe Rasmussen
Peter Vibe Rasmussen
AJArne Johannessen
Arne Johannessen
MHMorten Lock Hansen
Morten Lock Hansen
Aims: Overweight is associated with increased risk of atrial fibrillation (AF), but the impact of overweight and AF recurrence after ablation is less clear. Despite this, an increasing number of AF ablations are carried out in overweight patients. We investigated the impact of body mass index (BMI) on AF recurrence rates after ablation.Methods and results: Through Danish nationwide registers, all patients undergoing first-time AF ablation between 2010 and 2018 were identified. Exposure of interest was BMI. The primary outcome was recurrent AF, defined from either any usage of antiarrhythmic medication, AF hospitalization, cardioversion, or re-ablation. A total of 9188 patients were included. Median age and interquartile range was 64 (60–75) in the normal-weight group and 60 (53–66) in the morbidly obese. There was an increase in comorbidity burden with increasing BMI, including a higher prevalence of heart failure, chronic obstructive pulmonary disease, diabetes, and hypertension. At 1- and 5-year follow ups, recurrence rates of AF increased incrementally by BMI categories. The hazard ratios and 95% confidence intervals of recurrent AF after ablation were 1.15 (1.07–1.23), 1.18 (1.09–1.28), and 1.26 (1.13–1.41) in overweight, obese, and morbidly obese, respectively, compared with normal-weight patients. Procedure duration and X-ray dose exposure also increased with increasing BMI.Conclusion: Following AF ablation, recurrence rates of AF increased incrementally with increasing BMI. Therefore, aggressive weight management pre ablation in overweight patients could potentially provide substantial benefits and improve short- and long-term outcomes after ablation.

2 May 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
MDMattias Duytschaever
Mattias Duytschaever
GRGediminas Račkauskas
Gediminas Račkauskas
TPTom De Potter
Tom De Potter
JHJim Hansen
Jim Hansen
SKSebastien Knecht
Sebastien Knecht
PLPeter Lukac
Peter Lukac
Contact force (CF)–sensing radiofrequency (RF) catheters with an ablation index have shown reproducible outcomes for the treatment of atrial fibrillation (AF) in large multicentre studies. A dual-energy (DE) focal CF catheter to deliver RF and unipolar/biphasic pulsed field ablation (PFA), integrated with a three-dimensional (3D) mapping system, can provide operators with additional flexibility. The SmartfIRE study assessed the safety and efficacy of this novel technology for the treatment of drug-refractory, symptomatic paroxysmal AF. Results at 3 months post-ablation are presented here. Pulmonary vein isolation (PVI) was performed using a DE focal, irrigated CF-sensing catheter with the recommendation of PFA at posterior/inferior and RF ablation at the anterior/ridge/carina segments. Irrespective of energy, a tag size of 3 mm; an inter-tag distance ≤6 mm; a target index of 550 for anterior, roof, ridge, and carina; and a target index of 400 for posterior and inferior were recommended. Cavotricuspid isthmus ablation was permitted in patients with documented typical atrial flutter. The primary effectiveness endpoint was acute procedural success. The primary safety endpoint was the rate of primary adverse events (PAEs) within 7 days of the procedure. A prespecified patient subset underwent oesophageal endoscopy (EE; 72 h post-procedure), neurological assessment (NA; pre-procedure and discharge), and cardiac computed tomography (CT)/magnetic resonance angiogram (MRA) imaging (pre-procedure and 3 months post-procedure) for additional safety evaluation, and a mandatory remapping procedure (Day 75 ± 15) for PVI durability assessment. Of 149 patients enrolled between February and June 2023, 140 had the study catheter inserted (safety analysis set) and 137 had ablation energy delivered (per-protocol analysis set). The median (Q1/Q3) total procedure and fluoroscopy times were 108.0 (91.0/126.0) and 4.2 (2.3/7.7) min (n = 137). The acute procedural success rate was 100%. First-pass isolation was achieved in 89.1% of patients and 96.8% of veins. Cavotricuspid isthmus ablations were successfully performed in 12 patients [pulsed field (PF) only: 6, RF only: 5, and RF/PF: 1]. The PAE rate was 4.4% [6/137 patients; 2 pulmonary vein (PV) stenoses, 2 cardiac tamponades/perforations, 1 stroke, and 1 pericarditis]. No coronary artery spasm was reported. No oesophageal lesion was seen in the EE subset (0/31, 0%). In the NA subset (n = 30), microemboli lesions were identified in 2 patients (2/30, 6.7%), both of which were resolved at follow-up; only 1 was symptomatic (silent cerebral lesion, 3.3%). In the CT/MRA subset (n = 30), severe PV narrowing (of >70%) was detected in 2 patients (2/30, 6.7%; vein level 2/128, 1.6%), of whom 1 underwent dilatation and stenting and 1 was asymptomatic; both were associated with high index values and a small inter-tag distance. In the PV durability subset (n = 30), 100/115 treated PVs (87%) were durably isolated and 18/30 patients (60.0%) had all PVs durably isolated. A DE focal CF catheter with 3D mapping integration showed a 100% acute success rate with an acceptable safety profile in the treatment of paroxysmal AF. Prespecified 3-month remapping showed notable PVI durability. ClinicalTrials.gov Identifier: NCT05752487.