The species within Orobanchaceae cover all forms of parasitism from full autotrophy to holoparasitism. Although parasitic species have gone through dramatic genome changes, the plastomes of land plants generally contain highly conserved structures. We investigated the complete plastome sequence of hemiparasitic Pedicularis ishidoyana, belonging to the largest genus in Orobanchaceae, and compared it with the highly rearranged genomes of other taxa in that family. This plastome comprises a total of 152 571 bp, with two inverted repeats (IRs) of 35 281 bp, a large single-copy region (LSC) of 81 982 bp, and an extremely reduced small single-copy (SSC) region of 27 bp. Although IR expansion and SSC contraction have been reported in the plastomes of other hemiparasitic species in Orobanchaceae, the IR region of P. ishidoyana is extremely expanded, resulting in a very small SSC region. This genome contains 101 genes that encode 67 proteins, four rRNAs, 30 tRNAs, and 22 duplicated genes in the IR region. In contr...
30 March 2008 in Korean journal of applied entomology
(1) Background: The purpose of this study was to develop an image-guided endoscopic sinus surgery (IGESS) system, named Medigator®, based on the leave-one-out registration strategy and three-dimensional (3D) volumetric visualization of the nasal cavity and paranasal sinuses. (2) Methods: A phantom was designed and fabricated using a 3D printer. We then performed a phantom-based accuracy evaluation to validate the performance of the developed registration method. We included 11 patients who underwent IGESS for clinical study to compare the performance of the developed IGESS system with that of a commercialized system. (3) Results: The fiducial registration error (FRE) was 0.14 mm, and the target registration error (TRE) was 0.82 ± 0.50 mm by the phantom-based evaluation. As a result of the clinical comparative study, the average registration times were 36.04 ± 4.7 and 89.35 ± 26.1 s for the developed and commercialized systems, respectively (p < 0.05). The image loading time of the developed system was also shorter than that of the commercialized system (p < 0.05). The average accuracy score of the developed system was not significantly different from that of the commercialized system (p > 0.05). (4) Conclusions: The developed system provided an accurate point-to-point registration method based on the leave-one-out strategy. According to the results of the clinical comparative study, we demonstrated that the developed system showed reliable potential for clinical application.
1 November 2013 in Journal of Institute of Control, Robotics and Systems