Ali Erşen

Ali Erşen

Auto-generated profile, based on publicly available information

Ali Erşen

Department of Orthopedics and Traumatology, Faculty of Medicine, Istanbul University, 34093 Istanbul, Türkiye

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2013 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
AEAli Ersen
Ali Ersen
MDM. Demirhan
M. Demirhan
AAA. C. Atalar
A. C. Atalar
MKM. Kapicioğlu
M. Kapicioğlu
GBGokhan Baysal
Gokhan Baysal

1 December 2015 in International Journal of Surgery
Verified
Journal Article
Closed access
GKGökhan Karademir
Gökhan Karademir
YBYücel Bilgin
Yücel Bilgin
AEAli Erşen
Ali Erşen
GPGökhan Polat
Gökhan Polat
MBMehmet I. Buget
Mehmet I. Buget
HBHalil Ibrahim Balcı
Halil Ibrahim Balcı
Proximal femoral fractures are often seen in older patients and are associated with high mortality. Introduction to old age population is latening due to advancements in medical sciences and increasing life expectancy. The aim of the study was to evaluate factors affecting mortality in patients above 75 years of age who had been operated because of proximal femur fractures. Patients with age 75 and over who suffers from post-fall proximal femoral fracture who underwent surgery with one of following three methods (hemiarthroplasty, proximal femoral nail or total hip arthroplasty) were evaluated retrospectively. Effects on mortality were examined for factors such as type of surgery, type of anesthesia, preoperative ASA score (American Society of Anesthesiologists Score), need for intensive care, need for blood transfusion, operation waiting time and hospitalization duration. 115 patients who met inclusion criterion were included in the study out of 224 overall. 75 patients were women and 40 were males. Mortality rate after first year was found to be 40%. Patients over 85 years old had higher rates of mortality (p = 0,0003) than respectively younger patients (75-85). Sex was found to have no impact on mortality (p = 0.5039). There was no statistically significant difference in terms ASA score (p = 0.1518). Order of applied surgical methods with mortality risk rates was found to be total hip arthroplasty > hemiarthroplasty > proximal femoral nail (p = 0.0003). Type of anesthesia, the use of cement during arthroplasty, operation waiting time and hospitalization duration was not directly related with mortality rate (type of anesthesia p = 0.63, the use of cement during arthroplasty p = 0.223, operation waiting time p = 0.5 and hospitalization duration p = 0.19). Age is the primary risk factor on first year mortality in patients older than 75 years old with hip fractures. Addition to older age, more need to blood transfusions, and arthroplasty are other risk factors for first year mortality. It should be kept in mind that after 75 years old first year mortality may be higher if the patient is treated with arthroplasty.

6 January 2020 in Acta Orthopaedica et Traumatologica Turcica
Verified
Journal Article
Open access
MEMehmet Ersin
Mehmet Ersin
MDMehmet Demirel
Mehmet Demirel
MBMehmet İlKe Büget
Mehmet İlKe Büget
IEIpek Saadet Edipoglu
Ipek Saadet Edipoglu
AAAta Can Atalar
Ata Can Atalar
AEAli Erşen
Ali Erşen
Objective: The aim of this study was to determine the effect of intravenous (IV) tranexamic acid (TRX) use on visual clarity during arthroscopic rotator cuff repair. Methods: This prospective, randomized, double-blinded, placebo-controlled study was conducted in patients scheduled for an arthroscopic rotator cuff repair. In total, 60 patients were randomly distributed into two groups: control (28 patients: 11 male, 17 female; mean age=53 years, age range=19-65) and TRX (32 patients: 15 male, 17 female; mean age=50, age range=18-69). In the TRX group, the arthroscopy was performed through the bolus IV administration of 10 mg/kg TRX in 100 ml isotonic saline solution. In the control group, the arthroscopy was performed through the bolus IV administration of 100 ml isotonic saline solution. In both the groups, the IV administration was carried out after the induction of anesthesia. At the end of each procedure, the surgeon rated the visual clarity on a scale from 1 to 10. In addition, operation time (minutes), irrigation amount used in operation (lt), and the need of pressure increase because of bleeding were recorded. Results: No adverse effects were seen during the study period. Visual clarity in TRX group was significantly better than the control group (the mean visual clarity scores=8.1/10 (range=7-10) vs 7/10 (range=5-9); p=0.018). The amount of solution was significantly less in the TRX group (10.2 lt (range=3.5-21)) than in the control group (15.8 lt (range=5.8-27); p=0.007, post-hoc power=95.7%), although the operation time was slightly longer in the TRX group (106 minutes (range=50-210)) than in the control group (99 minutes (range=45-165); p=0.24). Moreover, the need for the increase in pressure owing to bleeding was found significantly less in the TRX group (5.8 times (range=(0-9)) than in the control group (9.6 times (range=0-13); p=0.04, post-hoc power=94.5%). Conclusion: Preoperative IV TRX administration seems to be effective in improving visual clarity and reducing the need for high pressure and the amount of irrigation fluid during the arthroscopic rotator cuff repair. Level of Evidence: Level II, Therapeutic study Cite this article as: Ersin M, Demirel M, Büget Mİ, Edipoğlu İS, Atalar AC, Erşen A. The effect of intravenous tranexamic acid on visual clarity during arthroscopic rotator cuff repair: A randomized, double-blinded, placebo-controlled pilot study. Acta Orthop Traumatol Turc 2020; 54(6): 572-6.

1 January 2017 in Acta Orthopaedica et Traumatologica Turcica
Verified
Journal Article
Open access
OTOnur Tunalı
Onur Tunalı
AEAli Erşen
Ali Erşen
MKMehmet Kapıcıoğlu
Mehmet Kapıcıoğlu
YSYavuz Sağlam
Yavuz Sağlam
MDMehmet Demirhan
Mehmet Demirhan
AAAta Can Atalar
Ata Can Atalar
Objectives: In intraarticular distal humerus fractures, internal fixation with double plates is the gold standard treatment. However the optimal plate configuration is not clear in the literature. The aim of this study was to compare the biomechanical stability of the parallel and the orthogonal anatomical locking plating systems in intraarticular distal humerus fractures in artificial humerus models. Methods: Intraarticular distal humerus fracture (AO13-C2) with 5 mm metaphyseal defect was created in sixteen artificial humeral models. Models were fixed with either orthogonal or parallel plating systems with locking screws (Acumed elbow plating systems). Both systems were tested for their stiffness with loads in axial compression, varus, valgus, anterior and posterior bending. Then plastic deformation after cyclic loading in posterior bending and load to failure in posterior bending were tested. The failure mechanisms of all the samples were observed. Results: Stiffness values in every direction were not significantly different among the orthogonal and the parallel plating groups. There was no statistical difference between the two groups in plastic deformation values (0.31 mme0.29 mm) and load to failure tests in posterior bending (372.4 Ne379.7 N). In the orthogonal plating system most of the failures occurred due to the proximal shaft fracture, whereas in the parallel plating system failure occurred due to the shift of the most distal screw in proximal fragment. Conclusion: Our study showed that both plating systems had similar biomechanical stabilities when anatomic plates with distal locking screws were used in intraarticular distal humerus fractures in artificial humerus models.

25 October 2019 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
IEİlker Eren
İlker Eren
AEAli Erşen
Ali Erşen
OBOlgar Birsel
Olgar Birsel
AAAta Can Atalar
Ata Can Atalar
POPiraye Oflazer
Piraye Oflazer
MDMehmet Demirhan
Mehmet Demirhan
Background: Facioscapulohumeral dystrophy (FSHD) is an autosomal-dominant myopathy characterized by facial and shoulder girdle muscle weakness with scapular winging. Scapulothoracic arthrodesis is a successful treatment approach for patients with <90° of shoulder elevation. The purpose of the present study was to assess functional outcomes and complications following scapulothoracic arthrodesis in patients with FSHD. Methods: We retrospectively reviewed the records of 40 patients (64 shoulders) in whom scapulothoracic arthrodesis was performed. To achieve fusion, multiple multifilament cables were used together with autologous bone and allograft bone. Preoperative and postoperative shoulder elevation and abduction; Disabilities of the Arm, Shoulder and Hand (Quick version, qDASH) scores; and pulmonary function were compared. Recorded complications were classified as pulmonary or scapular. Results: The mean age of the patients at the time of the operation was 25.4 years (range, 15 to 60 years), and the mean duration of follow-up was 71.2 months (range, 12 to 185 months). When the preoperative values were compared with those at the latest follow-up, significant improvement was noted in terms of elevation (from a mean [and standard deviation] of 60.6° ± 17.2° to 123.7° ± 26.7°; p < 0.001), abduction (from 52.7° ± 15.8° to 98.8° ± 20.3°; p < 0.001), and qDASH scores (from 34.7 ± 11.4 to 13.3 ± 13.1; p < 0.001). The overall complication rate was 26.6%. There were 7 pulmonary complications (4 pneumothoraxes, 2 pleural effusions, and 1 major atelectasis), and 5 chest tube placements were required. Ten complications (including 3 rib fractures, 1 brachial plexus palsy, 2 cases of implant irritation, 2 nonunions, 1 delayed union, and 1 scapular fracture) were related to the scapular fixation, and 7 revision procedures were required. Scapulothoracic fusion was achieved in all patients but 1, who had a scapular fracture. Pulmonary function tests were performed for 19 patients, and no difference was observed between preoperative and postoperative results. Conclusions: Scapulothoracic arthrodesis with use of multifilament cables is a successful surgical technique with high fusion rates and low morbidity. Pulmonary complications are common but resolve with careful attention. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

3 March 2017 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Closed access
PDF file
AEAli Ersen
Ali Ersen
FBFevzi Birisik
Fevzi Birisik
HOHakan Ozben
Hakan Ozben
AAAta Can Atalar
Ata Can Atalar
TSTurker Sahinkaya
Turker Sahinkaya
MDMehmet Demirhan
Mehmet Demirhan