1 February 2014 in Engineering Structures
1 July 2013 in Magazine of Concrete Research
Lightly reinforced concrete walls are commonly found in low-to-moderate seismic regions such as Australia. While many theoretical analyses on lateral load–displacement of structural walls have been proposed and widely used, not many have been developed for lightly reinforced concrete walls. The lateral load–displacement behaviour and failure mechanism of lightly reinforced structural walls differ to those of heavily reinforced concrete walls, particularly in terms of tension stiffening effects, possible failure mechanisms and drift capacities. An analytical study on lightly reinforced rectangular concrete walls is presented in this paper. A parametric study was conducted to provide initial insight into the effect of four design parameters (aspect ratio, axial load ratio, transverse reinforcement ratio and longitudinal reinforcement ratio) on the ultimate displacement capacity of reinforced concrete walls. Two analytical models were developed to predict the lateral load–displacement behaviour of lightly reinforced walls consisting of a detailed wall model and a simplified wall model that provides a quick and conservative estimate for initial design checking purposes using displacement-based principles. Both models are shown to provide good agreement with experimental results in the literature.
1 July 2010 in Engineering Structures
1 January 2018 in Advances in Civil Engineering
The compressive strength of concrete according to certain codes can be based on the compressive strength of unconfined plain standard concrete cylinders tests at the age of 28 days. In this paper, the standard concrete cylinders were spirally confined with steel bars and with/without hooked‐end steel fibers. The influence of the use of hooked‐end steel fiber in spirally confined concrete with various pitches was investigated. It can be seen that the use of hooked‐end steel fiber contributes significantly in improving both compressive strength and ductility of concrete. The compressive strength and ductility of steel fibered concrete also increase with the reduction of the spiral’s pitch.
1 January 2015 in Australian Journal of Structural Engineering
1 January 2014 in Australian Journal of Structural Engineering
This paper presents the findings of a research project investigating the lateral load drift behaviour of lightly reinforced concrete columns. Such columns of limited ductility are common in regions of low-moderate seismicity, and although their strength properties are well defined, the drift performance is less understood. The paper presents the results of an experimental study undertaken and the development of a theoretical model for predicting the lateral load-drift behaviour of lightly reinforced concrete columns together with a simplified bi-linear model for checking purposes. The test results are presented and clearly indicate the dramatic impact that the axial load ratio has on the drift performance of columns of limited ductility, particularly the significantly lower drift capacities that are available in compression dominated columns