Ilham Nassar-Eddine

Ilham Nassar-Eddine

Auto-generated profile, based on publicly available information

Ilham Nassar-Eddine

Laboratory of Electronics, Instrumentation and Energy (LEIE), Team: Exploitation and Processing of Renewable Energy, Faculty of Sciences Chouaib Doukkali University, El-Jadida, Morocco

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2016 in Energy Conversion and Management
Verified
Journal Article
Closed access
INI. Nassar-Eddine
I. Nassar-Eddine
AOA. Obbadi
A. Obbadi
YEYoussef Errami
Youssef Errami
AFA. El Fajri
A. El Fajri
MAM. Agunaou
M. Agunaou

1 September 2017 in Energy Conversion and Management
Verified
Journal Article
Closed access
KEK. Et-Torabi
K. Et-Torabi
INI. Nassar-Eddine
I. Nassar-Eddine
AOA. Obbadi
A. Obbadi
YEYoussef Errami
Youssef Errami
RRR. Rmaily
R. Rmaily
MAM. Agunaou
M. Agunaou

1 December 2017
Verified
Conference Paper
Closed access
INIlham Nassar-Eddine
Ilham Nassar-Eddine
KEKarima Et-Torabi
Karima Et-Torabi
RRRedouane Rmaily
Redouane Rmaily
AFAbdel Ilah Fake
Abdel Ilah Fake
AOAbdellatif Obbadi
Abdellatif Obbadi
MAMustapha Agunaou
Mustapha Agunaou
In this work, a comparative study of two parameter extraction methods: an iterative method based on Newton Raphson algorithm and an analytical method based on Lambert W function is presented. They are also tested on ST40 thin film photovoltaic (PV) panel. For both methods, five enhanced mathematical models are implemented to extract the parameters of this PV panel under varying environmental conditions. In order to validate the accuracy of the five models, the results of the models' simulation are compared with the measured data using the RMSE and AE. Then, the results of both methods are evaluated so as to ascertain which of them are more accurate. The results reported in this paper confirm that the models' simulation shows good agreement with the measured data. It is found that the analytical method with all five models is the most suitable for the thin film panel.

1 December 2018
Verified
Conference Paper
Closed access
INIlham Nassar-Eddine
Ilham Nassar-Eddine
KEKarima Et-Torabi
Karima Et-Torabi
RRRedouane Rmaily
Redouane Rmaily
AOAbdellatif Obbadi
Abdellatif Obbadi
YEYoussef Errami
Youssef Errami
MAMustapha Agunaou
Mustapha Agunaou
The present work suggests an accurate comparison of two methods for estimating the five physical parameters of photovoltaic (PV) multiycrystalline module from its manufacturer's datasheet, using a single diode model. The estimation methods used are the iterative method based on the Newton Raphson, and the analytical method based on the Lambert W function. The used methods are applied for multiycrystalline PV module to check the accuracy of these methods. The implementation of five improved mathematical models is required, to estimate the unknown parameters of multiycrystalline module under real operating conditions. The current absolute error (AE) is used to validate the accuracy of the improved models. Finally, the root mean square deviation (RMSD) and its normalized value (NRMSD), are calculated using three methods already existing in the literature, are also calculated by the two methods used in this study to prove the effectiveness of the used methods. The results confirm that the measured data is similar to improved models' curves. It is then found that the used methods are more accurate than the existing ones. Moreover, the results indicate that all models combined with iterative method are the most adaptable for the multicrystalline modules.

1 December 2018
Verified
Conference Paper
Closed access
KEKarima Et-Torabi
Karima Et-Torabi
INIlham Nassar-Eddine
Ilham Nassar-Eddine
RRRedouane Rmaily
Redouane Rmaily
AOAbdellatif Obbadi
Abdellatif Obbadi
YEYoussef Errami
Youssef Errami
MAMustapha Agunaou
Mustapha Agunaou
This paper compares two methods for extraction of photovoltaic (PV) module parameters. The numerical method called Gauss-Seidel, used on the single diode model, and the analytical method applied on the double diode model. Both methods are based on the manufacturer's datasheets to extract the five parameters. These methods are validated using monocrystalline PV module. The modified mathematical modeling equations are classified into models 1 to 5. Only model 2 and model 4 are used for the analytical method. Each model is based on the different combinations of the ideality factor, the series resistance, photocurrent and saturation current plotted under varying temperature and irradiance. The accuracy of PV module based on both methods is evaluated by Absolute Error (AE). In order to evaluate the effectiveness and accuracy of the proposed methods, the equations were implemented in the MATLAB/Simulink environment and the results obtained are compared with extracted experimental data.

23 October 2019
Verified
Conference Paper
Open access
INIlham Nassar-Eddine
Ilham Nassar-Eddine
AOAbdellatif Obbadi
Abdellatif Obbadi
YEYoussef Errami
Youssef Errami
SSSmail Sahnoun
Smail Sahnoun
MAMohssin Aoutoul
Mohssin Aoutoul
AFAbdelkrim El Fajri
Abdelkrim El Fajri