1. Superelastic titanium nickelide alloys find ever increasing application in medicine as implants for cardiac surgery, abdominal surgery, dentistry, traumatology, and gynecology [1–3]. Metal weft-...
25 June 2022 in Issues of Reconstructive and Plastic Surgery
Samples of metal knitted mesh made of the 40 μm, 60 μm and 90 μm diameter TiNi wires are studied by uniaxial tension to rupture and uniaxial cyclic tension. It was found that the metal knitted TiNi mesh behaves like a hyperelastic material under uniaxial tension in contrast to the superelastic wire from which it is made. Using the rheological models of Gent, Neo-Hookean, Mooney–Rivlin and Bergstrom-Boyce, the calculation of the cyclic tension of the knitted mesh was carried out. The similarity of the mechanical behavior of knitted mesh and biological tissues is shown. Criteria for quantitative assessment of the biomechanical compatibility of a knitted mesh implant for plasty of hyperelastic biological tissues are proposed.The main criteria for the rheological similarity of knitted mesh and soft tissues are the ultimate tensile strength, elastic modulus and the range of low-modulus and high-modulus elastic strain under loading and unloading; the residual strain value during cyclic tension.It has been found that knitted mesh made of superelastic TiNi wire exhibits a rubber-like behavior characteristic of hyperelastic materials under soft zero cyclic tension. At the same time, in the most loaded contact areas of the superelastic TiNi wire, the martensitic transition did not affect the tension cycles is due to friction, which counteracts the recovery of elastic strain during unloading. It has been established that the Bergstrom–Boyce model is closest in terms of the stress–strain diagram to the knitted mesh and biological tissues. Knitted mesh implants made of nickeide titanium wire were used for plasty of soft tissues and musculoskeletal complexes. The developed method for quantitative assessment diagram of the hyperelastic knittes mesh. The residual strain during the first two tension of the biocompatibility of the implant and biological tissue make it possible to choosу knitteв mesh with a certain wire diametre, focusing on the forces developed by the knitted mesh and the variable elasticity modulus. The knitted mesh was applied without additional fixation, using elastic self-fixation of knitted mesh loops into soft tissues.
In this work, the characteristics of the deformation behaviour of metal meshes knitted from thin NiTi wires have been studied and an experimental evaluation of their biological compatibility has been carried out. The experimental stress-strain diagrams obtained fully correspond to the typical tensile diagrams of superelastic NiTi alloys with marten-sitic transformation. The nonlinear dependencies of the stress of the metal mesh knitted from NiTi wire are rheologically similar to hyperelastic materials and differ from the ob-tained stress diagrams of the wire. It was found that the tensegrity structure of the knit-ted fabric limits the manifestation of the superelasticity effect characteristic of the wire. The tensile strength of the knitted fabric was found to be significantly lower than that of the wire. Using numerical modelling methods, it has been shown that the complex stress state of the metal mesh during deformation leads to inhomogeneity of the stress distribution in the structure and localisation of its maximum values in the contact area of the loops, confirming the hypothesis of suppression of superelasticity due to design features. An analysis of the stress distribution in the loops showed that stretching in the range of physiological loads does not lead to local destruction of the NiTi metal mesh. The results of an experimental macroscopic evaluation of the implantation area showed that there were no hernia defects in the endoprosthesis area and the adhesive process was recorded in only 3 (15 %) cases. The replacement area of the endoprosthesis was elastic and easily deformable. The porous surface structure of the NiTi wire, as well as the biomechanical and biochemical properties of the bilayer metal mesh, ensure optimal integration of the endoprosthesis into the body tissues and contribute to the formation of an elastic frame close to the natural one. Bilayer NiTi knitted mesh has shown promis-ing results in the replacement of complex anatomical structures, opening up prospects for further clinical research.
6 February 2025 in Mechanics of Advanced Materials and Structures