21 February 2022 in Applied Physics Letters
Holograms can shape wavefronts to produce arbitrary acoustic images. In this work, we experimentally demonstrate how acoustic holograms can produce controlled thermal patterns in absorbing media at ultrasonic frequencies. Magnetic resonance imaging (MRI)-compatible holographic ultrasound lenses were designed by time-reversal methods and manufactured using 3D-printing. Several thermal holographic patterns were measured using MRI thermometry and a thermographic camera in gelatin-milk phantoms and in an ex vivo liver tissue. The results show that acoustic holograms enable spatially controlled heating in arbitrary regions. Increasing the temperature using low-cost and MRI-compatible holographic transducers might be of great interest for many biomedical applications, such as ultrasound hyperthermia, where the control of specific thermal patterns is needed.
1 May 2018 in Physics in Medicine & Biology
Monitoring thermal therapies through medical imaging is essential in order to ensure that they are safe, efficient and reliable. In this paper, we propose a new approach, halfway between MR acoustic radiation force imaging (MR-ARFI) and MR elastography (MRE), allowing for the quantitative measurement of the elastic modulus of tissue in a highly localized manner. It relies on the simulation of the MR-ARFI profile, which depends on tissue biomechanical properties, and on the identification of tissue elasticity through the fitting of experimental displacement images measured using rapid MR-ARFI. This method was specifically developed to monitor MR-guided high intensity focused ultrasound (MRgHIFU) therapy. Elasticity changes were followed during HIFU ablations ( N = 6) performed ex vivo in porcine muscle samples, and were compared to temperature changes measured by MR-thermometry. Shear modulus was found to increase consistently and steadily a few seconds after the heating started, and such changes were found to be irreversible. The shear modulus was found to increase from 1.49 ± 0.48 kPa (before ablation) to 3.69 ± 0.93 kPa (after ablation and cooling). Thanks to its ability to perform quantitative elasticity measurements in a highly localized manner around the focal spot, this method proved to be particularly attractive for monitoring HIFU ablations.
8 September 2023 in Physics in Medicine & Biology
Focused ultrasound (FUS) is a non-invasive and highly promising method for targeted and reversible blood-brain barrier permeabilization. Numerous preclinical studies aim to optimize the localized delivery of drugs using this method in rodents and non-human primates. Several clinical trials have been initiated to treat various brain diseases in humans using simultaneous BBB permeabilization and drug injection. This review presents the state of the art of in vitro and in vivo cavitation control algorithms for BBB permeabilization using microbubbles (MB) and FUS. Firstly, we describe the different cavitation states, their physical significance in terms of MB behavior and their translation into the spectral composition of the backscattered signal. Next, we report the different indexes calculated and used during the ultrasonic monitoring of cavitation. Finally, the different in vitro and in vivo cavitation control strategies described in the literature are presented and compared.
1 January 2012 in Critical Reviews in Biomedical Engineering
Elasticity imaging methods aim at measuring the mechanical behavior of soft tissues by using medical imaging modalities, such as ultrasonography or magnetic resonance imaging. The initial motivation behind these techniques, and still the main one, is the need for new diagnostic tools based on the visualization of tissue stiffness. Recent developments have demonstrated the potential that elasticity imaging methods can offer in new fields other than direct medical diagnosis, such as the field of in vivo biomechanical characterization. After a short description of the general principles behind elasticity imaging, this review illustrates some of the most original clinical applications. The use of elastography for quantitative mechanical characterization is particularly emphasized, and original applications of these methods to several biomedical research fields are reviewed.
4 April 2015 in Magnetic Resonance in Medicine
Purpose: MRI‐guided thermal ablations require reliable monitoring methods to ensure complete destruction of the diseased tissue while avoiding damage to the surrounding healthy tissue. Based on the fact that thermal ablations result in substantial changes in biomechanical properties, interventional MR elastography (MRE) dedicated to the monitoring of MR‐guided thermal therapies is proposed here.Methods: Interventional MRE consists of a needle MRE driver, a fast and interactive gradient echo pulse sequence with motion encoding, and an inverse problem solver in real‐time. This complete protocol was tested in vivo on swine and the ability to monitor elasticity changes in real‐time was assessed in phantom.Results: Thanks to a short repetition time, a reduction of the number of phase‐offsets and the use of a sliding window, one refreshed elastogram was provided every 2.56 s for an excitation frequency of 100 Hz. In vivo elastograms of swine liver were successfully provided in real‐time during one breath‐hold. Changes of elasticity were successfully monitored in a phantom during its gelation with the same elastogram frame rate.Conclusion: This study demonstrates the ability of detecting elasticity changes in real‐time and providing elastograms in vivo with interventional MRE that could be used for the monitoring of thermal ablations. Magn Reson Med 75:1110–1118, 2016.
31 May 2022 in Scientific Reports
Magnetic Resonance (MR) Imaging-guided High Intensity focused Ultrasound (MRgHIFU) is a non-invasive, non-ionizing thermal ablation therapy that is particularly interesting for the palliative or curative treatment of musculoskeletal tumors. We introduce a new modular MRgHIFU device that allows the ultrasound transducer to be positioned precisely and interactively over the body part to be treated. A flexible, MR-compatible supporting structure allows free positioning of the transducer under MRI/optical fusion imaging guidance. The same structure can be rigidified using pneumatic depression, holding the transducer rigidly in place. Targeting accuracy was first evaluated in vitro. The average targeting error of the complete process was found to be equal to 5.4 ± 2.2 mm in terms of focus position, and 4.7° ± 2° in terms of transducer orientation. First-in-man feasibility is demonstrated on a patient suffering from important, uncontrolled pain from a bone metastasis located in the forearm. The 81 × 47 × 34 mm3 lesion was successfully treated using five successive positions of the transducer, under real-time monitoring by MR Thermometry. Significant pain palliation was observed 3 days after the intervention. The system described and characterized in this study is a particularly interesting modular, low-cost MRgHIFU device for musculoskeletal tumor therapy.