Diana Andrés

Ms. Diana Andrés

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2022 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
DADiana Andrés
Diana Andrés
JVJonathan Vappou
Jonathan Vappou
Noé JiménezNoé Jiménez
Noé Jiménez
Francisco CamarenaFrancisco Camarena
Francisco Camarena
Holograms can shape wavefronts to produce arbitrary acoustic images. In this work, we experimentally demonstrate how acoustic holograms can produce controlled thermal patterns in absorbing media at ultrasonic frequencies. Magnetic resonance imaging (MRI)-compatible holographic ultrasound lenses were designed by time-reversal methods and manufactured using 3D-printing. Several thermal holographic patterns were measured using MRI thermometry and a thermographic camera in gelatin-milk phantoms and in an ex vivo liver tissue. The results show that acoustic holograms enable spatially controlled heating in arbitrary regions. Increasing the temperature using low-cost and MRI-compatible holographic transducers might be of great interest for many biomedical applications, such as ultrasound hyperthermia, where the control of specific thermal patterns is needed.

28 April 2023 in Cancers
Verified
Journal Article
Open access
PDF file
DADiana Andrés
Diana Andrés
IRIan Rivens
Ian Rivens
Petros MouratidisPetros Mouratidis
Petros Mouratidis
Noé JiménezNoé Jiménez
Noé Jiménez
Francisco CamarenaFrancisco Camarena
Francisco Camarena
Gail ter HaarGail ter Haar
Gail ter Haar
Hyperthermia is currently used to treat cancer due to its ability to radio- and chemo-sensitize and to stimulate the immune response. While ultrasound is non-ionizing and can induce hyperthermia deep within the body non-invasively, achieving uniform and volumetric hyperthermia is challenging. This work presents a novel focused ultrasound hyperthermia system based on 3D-printed acoustic holograms combined with a high-intensity focused ultrasound (HIFU) transducer to produce a uniform iso-thermal dose in multiple targets. The system is designed with the aim of treating several 3D cell aggregates contained in an International Electrotechnical Commission (IEC) tissue-mimicking phantom with multiple wells, each holding a single tumor spheroid, with real-time temperature and thermal dose monitoring. System performance was validated using acoustic and thermal methods, ultimately yielding thermal doses in three wells that differed by less than 4%. The system was tested in vitro for delivery of thermal doses of 0–120 cumulative equivalent minutes at 43 °C (CEM43) to spheroids of U87-MG glioma cells. The effects of ultrasound-induced heating on the growth of these spheroids were compared with heating using a polymerase chain reaction (PCR) thermocycler. Results showed that exposing U87-MG spheroids to an ultrasound-induced thermal dose of 120 CEM43 shrank them by 15% and decreased their growth and metabolic activity more than seen in those exposed to a thermocycler-induced heating. This low-cost approach of modifying a HIFU transducer to deliver ultrasound hyperthermia opens new avenues for accurately controlling thermal dose delivery to complex therapeutic targets using tailored acoustic holograms. Spheroid data show that thermal and non-thermal mechanisms are implicated in the response of cancer cells to non-ablative ultrasound heating.

3 March 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
RBRachel Burstow
Rachel Burstow
DADiana Andrés
Diana Andrés
Noé JiménezNoé Jiménez
Noé Jiménez
Francisco CamarenaFrancisco Camarena
Francisco Camarena
Maya ThanouMaya Thanou
Maya Thanou
Antonios PouliopoulosAntonios Pouliopoulos
Antonios Pouliopoulos
Acoustic holography can be used to construct an arbitrary wavefront at a desired 2D plane or 3D volume by beam shaping an emitted field and is a relatively new technique in the field of biomedical applications. Acoustic holography was first theorized in 1985 following Gabor’s work in creating optical holograms in the 1940s. Recent developments in 3D printing have led to an easier and faster way to manufacture monolithic acoustic holographic lenses that can be attached to single-element transducers. As ultrasound passes through the lens material, a phase shift is applied to the waves, causing an interference pattern at the 2D image plane or 3D volume, which forms the desired pressure field. This technology has many applications already in use and has become of increasing interest for the biomedical community, particularly for treating regions that are notoriously difficult to operate on, such as the brain. Acoustic holograms could provide a non-invasive, precise, and patient specific way to deliver drugs, induce hyperthermia, or create tissue cell patterns. However, there are still limitations in acoustic holography, such as the difficulties in creating 3D holograms and the passivity of monolithic lenses. This review aims to outline the biomedical applications of acoustic holograms reported to date and discuss their current limitations and the future work that is needed for them to reach their full potential in the biomedical community.

26 October 2023 in Physical Review Applied
Verified
Journal Article
Closed access
PDF file
DADiana Andrés
Diana Andrés
AGAlicia Carrión García
Alicia Carrión García
FCFrancisco Camarena
Francisco Camarena
Noé JiménezNoé Jiménez
Noé Jiménez
Ultrasonic three-dimensional printed holograms are getting increasing interest for transcranial therapies since they can correct skull aberrations and, simultaneously, adapt the acoustic field to particular brain targets. However, evaluating the targeting performance of these systems requires the measurement of complex volumetric acoustic fields, which in many practical situations cannot be estimated by direct hydrophone measurements. In this work, we apply single-plane holographic measurement techniques to experimentally calibrate and measure the full volumetric field produced by holographic lenses. Two ex vivo test cases are presented, a four-foci lens and a preclinical case, both targeting through a macaque skull for potential applications in blood–brain barrier opening (BBBO) studies. Time-reversal and angular spectrum projection methods are compared to direct experimental measurements. Results show that holographic projection methods can reconstruct the complex acoustic images produced by holographic lenses, matching direct measurements in all test cases. However, while direct measurements are restricted to transverse-field cross sections, holographic projection allows estimating the field on the whole targeting volume. In this way, the location and the full three-dimensional shape of all acoustic foci can be obtained. Furthermore, these techniques can provide the field at the surface of the lens to compare it to the design phase distribution. Using this procedure, complex volumetric acoustic fields can be reconstructed, saving significant measurement time and computational resources, and enabling an accurate characterization of phase plates and other holographic lens topologies.

28 June 2024 in Applied Acoustics
Verified
Journal Article
Open access
NLNathalie Lamothe
Nathalie Lamothe
DADiana Andrés
Diana Andrés
AGAlicia Carrión García
Alicia Carrión García
FCFrancisco Camarena
Francisco Camarena
JPJosé A. Pineda-Pardo
José A. Pineda-Pardo
Noé JiménezNoé Jiménez
Noé Jiménez

1 May 2026 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Open access
FLF. Lopez-Berenguer
F. Lopez-Berenguer
AGAndrea Gonzalez-Montoro
Andrea Gonzalez-Montoro
MFM. Freire
M. Freire
AGA. González-Tamarit
A. González-Tamarit
SJS. Jiménez-Serrano
S. Jiménez-Serrano
AGAntonio J. Gonzalez
Antonio J. Gonzalez
Combining positron emission tomography (PET) with magnetic resonance imaging (MRI) and focused ultrasound (FUS) has emerged as a promising hybrid technique in the medical imaging field. Despite the potential benefits of using simultaneous PET and MRI acquisitions to monitor therapeutic effects and ensure precision and safety during FUS applications, no commercial or academic PET/MRI-guided FUS system (referred in the following as trimodal PET-MRI-FUS) exists. This work presents the design and evaluation of a preclinical PET insert for simultaneous operation with MRI and FUS systems. The proposed PET insert is based on monolithic LYSO crystals arranged in two octagonal rings that define inner and outer diameters of 72 and 114 mm, respectively, with an axial length of 67 mm. The system performance was evaluated according to the NEMA NU 4 2008 protocol. It achieves a uniform spatial resolution of ~0.9 mm along the whole PET Field of View (FOV) when enabling Depth of Interaction (DOI) capabilities. Moreover, we found a sensitivity peak of 3.8% for an energy window of 255–766 keV and a peak noise equivalent count rate peak of 80 kcps at an activity of 19 MBq. The compatibility of the PET insert with both low- and high-field MRI systems, as well as with custom and commercially available FUS devices, was studied using phantoms and in vivo experiments, respectively. The results of the trimodal tests have proven that the PET insert works simultaneously with both MRI and FUS systems.