Fault detection based on external leakage flux can address various faults, such as short-circuit faults in stators and rotors. External leakage flux sensing technology, as a noninvasive method, has been attracting increasing attention and research. However, for a high-power doubly fed induction generator (DFIG), the external leakage flux signals of the generator are easily overwhelmed by a strong noise background, and the fault diagnosis and recognition of stator interturn short circuit (S-ITSC) and rotor ITSC (R-ITSC) are complicated, which limit the practical engineering application of leakage flux sensing technology. Aiming at addressing ITSC faults in DFIGs, this article proposes a method for fault feature extraction and recognition of stator and rotor short circuits based on variational mode decomposition (VMD) and the refined composite multiscale dispersion entropy (RCMDE) analytical method for the external flux leakage of the generator. The optimized parameters of VMD are selected automatically by the genetic algorithm (GA), and VMD is adopted to adaptively decompose the external leakage flux signals into a series of intrinsic mode function (IMF) components. The evaluation criterion based on the correlation number in the frequency domain combined with the autocorrelation function is used to select the best IMF components with clear features. Two different components are chosen to reconstruct the flux leakage signal. The characteristic frequency of the reconstructed signal is analyzed by the Hilbert–Huang transform (HHT) and the total harmonic effective value of the characteristic component. To effectively identify and diagnose the generator S-ITSC and R-ITSC faults, RCMDE is used for the flux leakage reconstructed signal. The experimental results under different stator and rotor short-circuit levels show that this diagnosis method can effectively extract the weak feature information from the external flux leakage signals and perform fault feature extraction and recognition for stator and rotor short circuits.

23 August 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SZShouwang Zhao
Shouwang Zhao
YCYu Chen
Yu Chen
FLFeng Liang
Feng Liang
SZSichao Zhang
Sichao Zhang
NSNadeem Shahbaz
Nadeem Shahbaz
YCYonghong Cheng
Yonghong Cheng
Early fault detection is critical for ensuring reliable operation in wind power generation systems employing Doubly Fed Induction Generators (DFIGs). Although the widespread use of motor current signature analysis (MCSA) for noninvasive fault detection, early-stage faults in DFIGs often present with weak characteristic fault information, posing challenges for detection amidst noise and interference signals. This paper proposes a novel method to assess the severity of early stator interturn short circuits (ITSCs) in DFIGs by combining adaptive feature mode decomposition (AFMD) with multiscale analysis of complex component current trajectories. AFMD is applied to perform quadratic time-frequency decomposition of current signals, resulting in a series of modal components with diverse frequency contents. By selecting the low-frequency current modal components with the fundamental frequency and low-order harmonics, high-frequency interferences and noise are effectively filtered out. The extracted low-frequency current modal components undergo multiscale Park vector trajectory analysis, thereby enhancing the expression of weak fault characteristics associated with early ITSCs. Further analysis involves the extraction of negative sequence current (NSC) and zero-sequence current (ZSC) components from the low-frequency modal components. The residual ZSC signal is constructed by filter out the fundamental frequency and low-order harmonic components from the ZSC component of the low-frequency modal. Analysis of the symmetrized dot pattern of the residual ZSC signal captures the evolution process of early-stage ITSCs with a low number of turns. Additionally, the negative sequence current of the low-frequency modal components is qualitatively and quantitatively evaluated for early low-turn insulation short circuits of varying severity levels. Experimental validation on a 100 kW DFIG test platform demonstrates the efficacy of the proposed method in enhancing the detection and diagnosis of early-stage ITSC faults.

14 January 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
NSNadeem Shahbaz
Nadeem Shahbaz
YCYu Chen
Yu Chen
FLFeng Liang
Feng Liang
SZSichao Zhang
Sichao Zhang
SZShouwang Zhao
Shouwang Zhao
YZYong Zhao
Yong Zhao
This study proposed an effective machine learning (ML)-based fault diagnosis method for demagnetization faults, including "healthy, 30% unipolar demagnetization, 50% multi magnet demagnetization, 100% adjacent pole demagnetization, and 40% uniform demagnetization", in a 25-kW permanent magnet synchronous generator (PMSG) that considers algorithm accuracy and signal processing technique efficiency, top informative features, and training time of the ML algorithm. Our research involves developing a 3D finite element PMSG model in ANSYS Maxwell and conducting an industrial experiment to capture stator current and flux data. We employ advanced feature extraction techniques such as matching pursuit and discrete wavelet transform, assessing their accuracy using Ensemble, SVM, and KNN algorithms. Additionally, we optimize and rank features using ReliefF, mRMR, Chi2, ANOVA, and Kruskal‒Wallis filters, evaluating their impact on ML algorithms. The investigation extends to the evaluation of eight ML classifiers—ensemble, SVM, KNN, neural network, kernel, discriminant analysis, and naive Bayes—along with 31 subclassifiers to identify the most effective output signal, signal processing technique, informative features, suitable filters, and the optimal ML algorithm for diagnosing demagnetization faults in PMSGs. Our findings reveal that using flux signals in conjunction with the discrete wavelet transform, alongside the ANOVA feature ranking filter and fine Gaussian SVM algorithm, achieves 100% fault classification accuracy with a training time of 0.961 seconds. This approach proves highly effective for the early detection of demagnetization faults in PMSGs.

21 October 2021
Verified
Conference Paper
Closed access
YCYu Chen
Yu Chen
QSQingyun Shi
Qingyun Shi
GHGuorui Huang
Guorui Huang
LFLiang Feng
Liang Feng
SWShuang Wang
Shuang Wang
SLShulin Liu
Shulin Liu
In order to meet the needs of spacecraft electrification protection and structure design, a test system for true secondary electron emission yield spectrum of space materials has been developed in this paper to test the true secondary electron emission yield(TSEY) of dielectric materials. The test chamber is composed of an injection chamber and an analysis chamber. Each chamber has its vacuum acquisition and detection functions. The internal four-dimensional electronic control test displacement platform, to achieve the adjustment of the sample position; During the test, an electron gun with an energy range of 0 ~ 2000eV was used to generate the electron beam. The true secondary electron emission coefficient of dielectric materials can be measured by pressurizing the Faraday cup and the grid. The true secondary electrons and backscattered electrons are collected and measured by the Faraday cup structure with the grid. The dielectric material was tested by the pulse method. The signal generator controlled the emission time of the electron gun under different energy by generating a pulse signal of 30μs. The current signals of the Faraday cup and sample stand were measured by an oscilloscope, respectively. In this paper, the true secondary electron emission coefficient of dielectric materials is measured by using an electron gun to emit low-energy electrons and neutralize the excess charge on the material's surface. The results show that Kapton's true secondary electron emission coefficient can be effectively measured under different electron incident conditions.