1 September 2023 in New Journal of Physics
We present a new framework to study the time variation of fundamental constants in a model-independent way. Model independence implies more free parameters than assumed in previous studies. Using data from atomic clocks based on87Sr,171Yb+and133Cs, we set bounds on parameters controlling the variation of the fine-structure constant,α, and the electron-to-proton mass ratio,µ. We consider variations on timescales ranging from a minute to almost a day. In addition, we use our results to derive some of the tightest limits to date on the parameter space of models of ultralight dark matter and axion-like particles.
17 June 2024 in Metrologia
A full evaluation of the uncertainty budget for the ytterbium ion optical clock at the National Physical Laboratory (NPL) was performed on the electric octupole (E3) transition. The total systematic frequency shift was measured with a fractional standard systematic uncertainty of . Furthermore, the absolute frequency of the E3 transition of the 171Yb+ ion was measured between 2019 and 2023 via a link to International Atomic Time (TAI) and against the local caesium fountain NPL-CsF2. The absolute frequencies were measured with fractional standard uncertainties between and , and all were in agreement with the 2021 BIPM recommended frequency.
21 February 2024 in Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences
Optical atomic clocks demonstrate a better stability and lower systematic uncertainty than the highest performance microwave atomic clocks. However, the best performing optical clocks have a large footprint in a laboratory environment and require specialist skills to maintain continuous operation. Growing and evolving needs across several sectors are increasing the demand for compact robust and portable devices at this capability level. In this paper we discuss the design of a physics package for a compact laser-cooled 88 Sr + optical clock that would, with further development, be suitable for space deployment. We review the design parameters to target a relative frequency uncertainty at the low parts in 10 18 with this system. We then explain the results of finite-element modelling to simulate the response of the ion trap and vacuum chamber to vibration, shock and thermal conditions expected during launch and space deployment. Additionally, an electrostatic model has been developed to investigate the relationship between the ion trap geometrical tolerances and the trapping efficiency. We present the results from these analyses that have led to the design of a more robust prototype ready for experimental testing.
1 September 2026 in Physical Review Research
Optical clocks have achieved remarkable estimated fractional frequency uncertainties reaching the 10 − 18 level and below, enabling applications in fundamental physics, general relativity, and geodesy. However, the challenge of verifying the international consistency of optical clocks remains critical as efforts intensify toward redefining the SI second based on an optical transition or transitions. We report on a two-month international clock comparison campaign involving seven optical clocks in four national metrology institutes (INRIM, LNE-OP, NPL, and PTB) connected via the optical fiber network established in Europe. The campaign resulted in optical frequency ratios with uncertainties ranging from 7.7 × 10 − 18 to 6.1 × 10 − 17 . Among the results, the Yb + 171 ( E 3 ) clocks at NPL and PTB demonstrated agreement within an uncertainty of 7.7 × 10 − 18 , marking the first international verification of two independently developed optical clocks below one part in 10 17 . The operation of the Hg 199 clock at LNE-OP (formerly LNE-SYRTE) resulted in frequency ratios with improved uncertainties with Yb + 171 ( E 3 ) , Yb 171 , and Sr 87 optical clocks. These results provide input for the redefinition of the second and underscore how fiber-linked clock networks can advance metrology and scientific applications.