Billy I. Robertson

Billy I. Robertson

Auto-generated profile, based on publicly available information

Billy I. Robertson

National Physical Laboratory

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2023 in New Journal of Physics
Verified
Journal Article
Open access
PDF file
NSNathaniel Sherrill
Nathaniel Sherrill
APAdam O Parsons
Adam O Parsons
CBCharles F A Baynham
Charles F A Baynham
WBWilliam Bowden
William Bowden
ECElizabeth Anne Curtis
Elizabeth Anne Curtis
Xavier  CalmetXavier Calmet
Xavier Calmet
We present a new framework to study the time variation of fundamental constants in a model-independent way. Model independence implies more free parameters than assumed in previous studies. Using data from atomic clocks based on87Sr,171Yb+and133Cs, we set bounds on parameters controlling the variation of the fine-structure constant,α, and the electron-to-proton mass ratio,µ. We consider variations on timescales ranging from a minute to almost a day. In addition, we use our results to derive some of the tightest limits to date on the parameter space of models of ultralight dark matter and axion-like particles.

17 June 2024 in Metrologia
Verified
Journal Article
Open access
ATA Tofful
A Tofful
CBC F A Baynham
C F A Baynham
ECE A Curtis
E A Curtis
APA O Parsons
A O Parsons
BRB I Robertson
B I Robertson
RGR M Godun
R M Godun
A full evaluation of the uncertainty budget for the ytterbium ion optical clock at the National Physical Laboratory (NPL) was performed on the electric octupole (E3) 2 S 1 / 2 → 2 F 7 / 2 transition. The total systematic frequency shift was measured with a fractional standard systematic uncertainty of 2.2 × 10 − 18 . Furthermore, the absolute frequency of the E3 transition of the 171Yb+ ion was measured between 2019 and 2023 via a link to International Atomic Time (TAI) and against the local caesium fountain NPL-CsF2. The absolute frequencies were measured with fractional standard uncertainties between 3.7 × 10 − 16 and 1.1 × 10 − 15 , and all were in agreement with the 2021 BIPM recommended frequency.

21 February 2024 in Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences
Verified
Journal Article
Closed access
ASAlessio Spampinato
Alessio Spampinato
JSJonathan Stacey
Jonathan Stacey
SMSean Mulholland
Sean Mulholland
BRBilly I. Robertson
Billy I. Robertson
HKHugh A. Klein
Hugh A. Klein
PGPatrick Gill
Patrick Gill
Optical atomic clocks demonstrate a better stability and lower systematic uncertainty than the highest performance microwave atomic clocks. However, the best performing optical clocks have a large footprint in a laboratory environment and require specialist skills to maintain continuous operation. Growing and evolving needs across several sectors are increasing the demand for compact robust and portable devices at this capability level. In this paper we discuss the design of a physics package for a compact laser-cooled 88 Sr + optical clock that would, with further development, be suitable for space deployment. We review the design parameters to target a relative frequency uncertainty at the low parts in 10 18 with this system. We then explain the results of finite-element modelling to simulate the response of the ion trap and vacuum chamber to vibration, shock and thermal conditions expected during launch and space deployment. Additionally, an electrostatic model has been developed to investigate the relationship between the ion trap geometrical tolerances and the trapping efficiency. We present the results from these analyses that have led to the design of a more robust prototype ready for experimental testing.

1 September 2026 in Physical Review Research
Verified
Journal Article
Open access
PDF file
MPMarco Pizzocaro
Marco Pizzocaro
CZClara Zyskind
Clara Zyskind
AAAnne Amy-Klein
Anne Amy-Klein
EBErik Benkler
Erik Benkler
SBSebastien Bize
Sebastien Bize
JTJacob Tunesi
Jacob Tunesi
Optical clocks have achieved remarkable estimated fractional frequency uncertainties reaching the 10 − 18 level and below, enabling applications in fundamental physics, general relativity, and geodesy. However, the challenge of verifying the international consistency of optical clocks remains critical as efforts intensify toward redefining the SI second based on an optical transition or transitions. We report on a two-month international clock comparison campaign involving seven optical clocks in four national metrology institutes (INRIM, LNE-OP, NPL, and PTB) connected via the optical fiber network established in Europe. The campaign resulted in optical frequency ratios with uncertainties ranging from 7.7 × 10 − 18 to 6.1 × 10 − 17 . Among the results, the Yb + 171 ( E 3 ) clocks at NPL and PTB demonstrated agreement within an uncertainty of 7.7 × 10 − 18 , marking the first international verification of two independently developed optical clocks below one part in 10 17 . The operation of the Hg 199 clock at LNE-OP (formerly LNE-SYRTE) resulted in frequency ratios with improved uncertainties with Yb + 171 ( E 3 ) , Yb 171 , and Sr 87 optical clocks. These results provide input for the redefinition of the second and underscore how fiber-linked clock networks can advance metrology and scientific applications.