Josephine Gehrels

Josephine Gehrels

Auto-generated profile, based on publicly available information

Josephine Gehrels

Philips Medical Systems Nederland B.V., acting through its Circular Equipment organization, Veenpluis 6, 5684 PC Best, Netherlands

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2024 in Radiology
Verified
Journal Article
Closed access
CTCassandra L. Thiel
Cassandra L. Thiel
MVMarta Vigil-Garcia
Marta Vigil-Garcia
SNSachin Nande
Sachin Nande
CMCecilia Meijer
Cecilia Meijer
JGJosephine Gehrels
Josephine Gehrels
JSJohn R Scheel
John R Scheel
A life cycle assessment of a diagnostic radiology department’s environmental footprint identified the energy consumption from imaging equipment as more than 50% of its greenhouse gas emissions, as well as opportunities to improve its sustainability.

5 October 2025 in Journal of the American College of Radiology
Verified
Journal Article
Open access
DCDiana E. Carver
Diana E. Carver
SPSumit Pruthi
Sumit Pruthi
OSOlesya Struk
Olesya Struk
MVMarta Vigil-Garcia
Marta Vigil-Garcia
CMCecilia Meijer
Cecilia Meijer
CTCassandra L. Thiel
Cassandra L. Thiel
To assess the environmental impact of magnetic resonance (MR) and computed tomography (CT) imaging using life cycle assessment (LCA), focusing on energy use, resource consumption, and emissions. This ISO 14040-guided LCA-based study focused on MRI and CT services, including the production and use of three MRI and four CT scanners, at a quaternary care 800-bed academic medical center in the Southeastern USA over a one-year period. Data were collected through direct observation, record review, staff interviews, and energy metering. Environmental impacts were assessed using SimaPro 9.3.0.2 and the Ecoinvent v3.8 database. MRI and CT services at this site generate an estimated 221 and 108 tons of CO2e per year, respectively. This is equivalent to the emissions of 52 (MRI) and 25 (CT) cars driven annually. Energy consumption accounted for the largest portion of emissions (58% for MRI, 33% for CT), followed by disposable supplies (26% for MRI, 16% for CT), capital equipment production (7% for MRI, 13% for CT), and linens (4% for MRI, 11% for CT). Switching to solar photovoltaic electricity could reduce total MRI emissions by 70% and CT emissions by 40%, increasing the relative impacts of scanner production, disposable supplies, and linens. This study highlights the significant environmental impact of MRI and CT services, particularly energy consumption. Renewable energy sources, such as solar photovoltaics, offer the greatest potential for mitigating the environmental footprint. Additional strategies include optimizing scanner utilization, adopting reusable or reprocessable supplies, and embracing circular business practices such as circular manufacturing and extending the lifespan of capital equipment.

5 October 2025 in Journal of the American College of Radiology
Verified
Journal Article
Open access
KFKatherine Frederick-Dyer
Katherine Frederick-Dyer
CTCassandra L. Thiel
Cassandra L. Thiel
JLJessica R. Leschied
Jessica R. Leschied
OSOlesya Struk
Olesya Struk
MVMarta Vigil-Garcia
Marta Vigil-Garcia
DCDiana E. Carver
Diana E. Carver

4 October 2025 in Journal of the American College of Radiology
Verified
Journal Article
Open access
ESElizabeth J. Snyder
Elizabeth J. Snyder
CTCassandra L. Thiel
Cassandra L. Thiel
OSOlesya Struk
Olesya Struk
MVMarta Vigil-Garcia
Marta Vigil-Garcia
CMCecilia Meijer
Cecilia Meijer
DCDiana E. Carver
Diana E. Carver
To assess the environmental impact of radiography and fluoroscopy, using life cycle assessment (LCA), focusing on energy use and emissions. This ISO 14040-guided LCA-based study focused on radiography and fluoroscopy services, including the production and use of two radiography and two fluoroscopy machines, at a quaternary care 800-bed academic medical center in the Southeastern United States over a 1-year period. Data were collected through direct observation, record review, staff interviews, and energy metering. Environmental impacts were assessed using SimaPro 9.3.0.2 and the Ecoinvent v3.8 database. Radiography and fluoroscopy activities generated an estimated 55,100 kilograms of CO2 equivalents (kg CO2e) per year. Energy use was the main contributor (47%), with fluoroscopy having much higher per-scan emissions (4.8 and 9.6 kg CO2e per scan) than radiography (0.8 kg CO2e per scan). Medical linens or textiles accounted for 24% of total emissions. Other significant environmental impacts included ozone depletion, smog, acidification, and eutrophication. Reducing energy consumption by decarbonizing electricity sources and optimizing equipment use can significantly decrease greenhouse gas emissions. Implementing sustainable practices in linen use, procurement, and end-of-life management is also crucial. Reducing low-value imaging can further mitigate environmental impact.