Diana E. Carver

Diana E. Carver

Auto-generated profile, based on publicly available information

Diana E. Carver

Department of Radiology Vanderbilt University Medical Center, 1211 Medical Center Dr VUH 1145, Nashville, TN 37212, United States

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2024 in Radiology
Verified
Journal Article
Closed access
CTCassandra L. Thiel
Cassandra L. Thiel
MVMarta Vigil-Garcia
Marta Vigil-Garcia
SNSachin Nande
Sachin Nande
CMCecilia Meijer
Cecilia Meijer
JGJosephine Gehrels
Josephine Gehrels
JSJohn R Scheel
John R Scheel
A life cycle assessment of a diagnostic radiology department’s environmental footprint identified the energy consumption from imaging equipment as more than 50% of its greenhouse gas emissions, as well as opportunities to improve its sustainability.

4 July 2015 in Pediatric Radiology
Verified
Journal Article
Closed access
PDF file
SKSusan D. Kost
Susan D. Kost
NFNicholas D. Fraser
Nicholas D. Fraser
DCDiana E. Carver
Diana E. Carver
DPDavid R. Pickens
David R. Pickens
RPRonald R. Price
Ronald R. Price
MSMichael G. Stabin
Michael G. Stabin

5 October 2025 in Journal of the American College of Radiology
Verified
Journal Article
Open access
DCDiana E. Carver
Diana E. Carver
SPSumit Pruthi
Sumit Pruthi
OSOlesya Struk
Olesya Struk
MVMarta Vigil-Garcia
Marta Vigil-Garcia
CMCecilia Meijer
Cecilia Meijer
CTCassandra L. Thiel
Cassandra L. Thiel
To assess the environmental impact of magnetic resonance (MR) and computed tomography (CT) imaging using life cycle assessment (LCA), focusing on energy use, resource consumption, and emissions. This ISO 14040-guided LCA-based study focused on MRI and CT services, including the production and use of three MRI and four CT scanners, at a quaternary care 800-bed academic medical center in the Southeastern USA over a one-year period. Data were collected through direct observation, record review, staff interviews, and energy metering. Environmental impacts were assessed using SimaPro 9.3.0.2 and the Ecoinvent v3.8 database. MRI and CT services at this site generate an estimated 221 and 108 tons of CO2e per year, respectively. This is equivalent to the emissions of 52 (MRI) and 25 (CT) cars driven annually. Energy consumption accounted for the largest portion of emissions (58% for MRI, 33% for CT), followed by disposable supplies (26% for MRI, 16% for CT), capital equipment production (7% for MRI, 13% for CT), and linens (4% for MRI, 11% for CT). Switching to solar photovoltaic electricity could reduce total MRI emissions by 70% and CT emissions by 40%, increasing the relative impacts of scanner production, disposable supplies, and linens. This study highlights the significant environmental impact of MRI and CT services, particularly energy consumption. Renewable energy sources, such as solar photovoltaics, offer the greatest potential for mitigating the environmental footprint. Additional strategies include optimizing scanner utilization, adopting reusable or reprocessable supplies, and embracing circular business practices such as circular manufacturing and extending the lifespan of capital equipment.

10 March 2017 in Pediatric Radiology
Verified
Journal Article
Closed access
PDF file
DCDiana E. Carver
Diana E. Carver
SKSusan D. Kost
Susan D. Kost
NFNicholas D. Fraser
Nicholas D. Fraser
WSW. Paul Segars
W. Paul Segars
DPDavid R. Pickens
David R. Pickens
MSMichael G. Stabin
Michael G. Stabin

1 April 2015 in Health Physics
Verified
Journal Article
Closed access
DCD. E. Carver
D. E. Carver
SKS. D. Kost
S. D. Kost
MFM. J. Fernald
M. J. Fernald
KLK. G. Ii Lewis
K. G. Ii Lewis
NFN. D. Fraser
N. D. Fraser
MSM. G. Stabin
M. G. Stabin
The authors have created a radiation transport code using the GEANT4 Monte Carlo toolkit to simulate pediatric patients undergoing CT examinations. The focus of this paper is to validate their simulation with real-world physical dosimetry measurements using two independent techniques. Exposure measurements were made with a standard 100‐mm CT pencil ionization chamber, and absorbed doses were also measured using optically stimulated luminescent (OSL) dosimeters. Measurements were made in air with a standard 16‐cm acrylic head phantom and with a standard 32‐cm acrylic body phantom. Physical dose measurements determined from the ionization chamber in air for 100 and 120 kVp beam energies were used to derive photon-fluence calibration factors. Both ion chamber and OSL measurement results provide useful comparisons in the validation of the Monte Carlo simulations. It was found that simulated and measured CTDI values were within an overall average of 6% of each other.

5 October 2025 in Journal of the American College of Radiology
Verified
Journal Article
Open access
KFKatherine Frederick-Dyer
Katherine Frederick-Dyer
CTCassandra L. Thiel
Cassandra L. Thiel
JLJessica R. Leschied
Jessica R. Leschied
OSOlesya Struk
Olesya Struk
MVMarta Vigil-Garcia
Marta Vigil-Garcia
DCDiana E. Carver
Diana E. Carver