22 August 2016 in Review of Scientific Instruments
A filterscope diagnostic system has been mounted to observe the line emission and visible bremsstrahlung emission from plasma on the experimental advanced superconducting tokamak during the 2014 campaign. By this diagnostic system, multiple wavelengths including Dα (656.1 nm), Dγ (433.9 nm), He ii (468.5 nm), Li i (670.8 nm), Li ii (548.3 nm), C iii (465.0 nm), O ii (441.5 nm), Mo i (386.4 nm), W i (400.9 nm), and visible bremsstrahlung radiation (538.0 nm) are monitored with corresponding wavelength filters. All these multi-channel signals are digitized at up to 200 kHz simultaneously. This diagnostic plays a crucial role in studying edge localized modes and H-mode plasmas, due to the high temporal resolution and spatial resolution that have been designed into it.
1 August 2018 in Physics of Plasmas
Hot spots induced by lower hybrid wave in experimental advanced superconducting tokamak tokamak have caused high performance experiment disruption and serious damages to the guard limiters. Experimental and theoretical analyses have been carried out to study its physical mechanism. Plasma density scan experiments indicate that the wall temperature within the hot spots enhanced by a factor of 5 and increases with the plasma density near the antenna. A lower hybrid current drive (LHCD)-only density climb experiment shows that the carbon impurity decreases to a minimum value at certain plasma density and then increases with the line averaged plasma density. A model has been developed to explain the mechanism of sputtering of graphite tiles due to hot spots as the plasma density near the LHCD antenna and the time increases. A theoretical scaling of the heat flux driven by LHCD is also presented and is consistent with the experimental scaling in the Tore Supra tokamak. The simulation results show that the total sputtering flux density has a minimum at a certain plasma density and gradually increases as the plasma density increases or decreases away from the minimum value, and the increase in parallel heat flux near the antenna would enhance the sputtering flux density. The sputtering flux density trend is qualitatively consistent with the density scan experiments. The simulated temporal evolution of sputtered flux implies that the chemical sputtering could be a candidate for the carbon impurity explosion.
26 September 2016 in Review of Scientific Instruments
In toroidal magnetic fusion devices, fast-ion D-alpha diagnostic (FIDA) is a powerful method to study the fast-ion feature. The fast-ion characteristics can be inferred from the Doppler shifted spectrum of Dα light according to charge exchange recombination process between fast ions and probe beam. Since conceptual design presented in the last HTPD conference, significant progress has been made to apply FIDA systems on the Experimental Advanced Superconducting Tokamak (EAST). Both co-current and counter-current neutral beam injectors are available, and each can deliver 2-4 MW beam power with 50-80 keV beam energy. Presently, two sets of high throughput spectrometer systems have been installed on EAST, allowing to capture passing and trapped fast-ion characteristics simultaneously, using Kaiser HoloSpec transmission grating spectrometer and Bunkoukeiki FLP-200 volume phase holographic spectrometer coupled with Princeton Instruments ProEM 1024B eXcelon and Andor DU-888 iXon3 1024 CCD camera, respectively. This paper will present the details of the hardware descriptions and experimental spectrum.
1 November 1999 in Nuclear Fusion
1 December 2022 in Review of Scientific Instruments
Two pairs of space-resolved extreme ultraviolet (EUV) spectrometers working at 5–138 Å with different vertical observation ranges of −7 ≤ Z ≤ 19 and −18 ≤ Z ≤ 8 cm have been newly developed to observe the radial profile of impurity line emissions and to study the transport of high-Z impurity ions intrinsically existing in EAST tokamak plasmas. Both spectrometers are equipped with a complementary metal-oxide semiconductor (CMOS) detector (Andor Marana-X 4.2B-6, Oxford Instruments) with sensitive area of 13.3 × 13.3 mm2 and number of pixels equal to 2048 × 2048 (6.5 × 6.5 µm2/pixels). Compared to the currently operating space-resolved EUV spectrometers with a charge-coupled detector (CCD: 1024 × 255 pixels, 26 × 26 µm2) working at 30–520 Å, this spectrometer’s performance was substantially improved by using the CMOS detector. First, the spectral resolution measured at full width at half maximum was improved in the whole wavelength range, e.g., Δλ1/2_CMOS = 0.092 Å and Δλ1/2_CCD = 0.124 Å at C VI 33.73 Å and Δλ1/2_CMOS = 0.104 Å and Δλ1/2_CCD = 0.228 Å at Mo XXXI 115.999 Å, thus enabling a more accurate analysis of spectra with complicated structure such as tungsten unresolved transition array in the range 45–65 Å. Second, the temporal resolution was largely improved due to the high-speed data acquisition system of the CMOS detector, e.g., Δt_CMOS = 15 ms/frame and Δt_CCD = 200 ms/frame at routine operation in the radial profile measurement. Third, signal saturation issues that occurred when using the old CCD sensor during impurity accumulation now disappeared entirely using the CMOS detector due to lower exposure time at high readout rates, which largely improved the observation performance in similar impurity burst events. The above-mentioned performance improvements of the space-resolved EUV spectrometer led to a rapid change in the W XXXIII (52.22 Å) radial profile during a single cycle of low-frequency sawtooth oscillation with fst = 5–6 Hz at a sufficient detector count rate.
6 September 2016 in Review of Scientific Instruments
Volume recombination plays an important role towards plasma detachment for magnetically confined fusion devices. High quantum number states of the Balmer series of deuterium are used to study recombination. On EAST (Experimental Advanced Superconducting Tokamak), two visible spectroscopic measurements are applied for the upper/lower divertor with 13 channels, respectively. Both systems are coupled with Princeton Instruments ProEM EMCCD 1024B camera: one is equipped on an Acton SP2750 spectrometer, which has a high spectral resolution ∼0.0049 nm with 2400 gr/mm grating to measure the Dα(Hα) spectral line and with 1200 gr/mm grating to measure deuterium molecular Fulcher band emissions and another is equipped on IsoPlane SCT320 using 600 gr/mm to measure high-n Balmer series emission lines, allowing us to study volume recombination on EAST and to obtain the related line averaged plasma parameters (Te, ne) during EAST detached phases. This paper will present the details of the measurements and the characteristics of deuterium Balmer series line emissions during density ramp-up L-mode USN plasma on EAST.