5 April 2010 in IEEE Transactions on Power Delivery
This paper presents a three-phase power-flow algorithm, in the sequence-component frame, for the microgrid (μgrid) and active distribution system (ADS) applications. The developed algorithm accommodates single-phase laterals, unbalanced loads and lines, and three/four-wire distribution lines. This paper also presents steady-state sequence-component frame models of distributed energy resource (DER) units for the developed power-flow approach under balanced/unbalanced conditions. The DER models represent the synchronous-generator based and the electronically-coupled DER units. Both constant power (PQ) and regulated-voltage (PV) modes of operation of DER units are considered. The application of the developed power-flow method for two study systems is presented. The study results are validated based on comparison with the detailed solution of the system differential equations in time domain, using the PSCAD/EMTDC software tool.
6 January 2011 in IEEE Transactions on Power Delivery
This paper develops and presents a unified and generic three-phase, steady-state, fundamental-frequency, sequence-frame-based model of the voltage-sourced converter (VSC) for power-flow analysis of VSC-interfaced Distributed Energy Resource (DER) units. The model is unified since it represents: 1) three-wire and four-wire VSC configurations; 2) balanced and unbalanced power-flow scenarios; 3) various VSC control strategies and options; and 4) operating limits and constraints of the VSC and its host DER unit. Based on the developed model, a new power-flow algorithm in the sequence-component frame is also developed. To achieve numerical and computational efficiency, the interface-VSC operating limits are accommodated in the power-flow algorithm as an interleaved step. The accuracy of the developed model and the computational efficiency of the power-flow algorithm are demonstrated based on several case studies, and where applicable, the results are validated based on comparison with the exact time-domain solution, using the PSCAD/EMTDC software tool.
1 October 2008 in Electric Power Systems Research
1 May 2012 in IEEE Transactions on Smart Grid
This paper proposes and develops a new distributed slack bus (DSB) model , in the sequence-components frame, for power-flow analysis of an islanded active distribution network (ADN) dominated by electronically coupled distributed energy resource (DER) units. The power-flow analysis distributes the system slack among several participating sources since, unlike the grid-connected systems, the reference bus DER unit is anticipated to have a limited power capacity. The main application of the DSB model is for a fast power-flow analysis of an islanded ADN to enable its real-time energy management and prevent DER capacity violation in between two consecutive optimal power-flow runs. Unlike the existing DSB models, the proposed model incorporates i) the participation of DER units with different control strategies (PQ and PV) in the system real and reactive slack compensation and ii) the DER power capacity limits. Based on a new definition of the “participating sources,” the power-flow equations are augmented to incorporate the system real and reactive power slack as state variables. The proposed DSB formulation is incorporated in a sequence-frame power-flow solver (SFPS). Case studies are conducted to evaluate the impacts of adopting the proposed DSB model in the SFPS tool.
17 May 2021 in IEEE Access
This paper introduces the application of a newly developed heuristic nature-inspired optimization technique, viz, tuned Marine Predator Algorithm (MPA), to solve the optimal power flow (OPF) problem of multi-regional systems. The paper proposes MPA parameters’ tuning to enhance the algorithm performance. The paper takes into account the variability of different types of renewable energy resources (RERs) and loads. Two modeling approaches are presented: holistic (multi-regions are modeled as one large network) and inter-bounded (modeling the regional interfaces). The MPA is applied to the IEEE-48 bus connected system, and the results are compared with another well-established heuristic algorithm, namely the Genetic Algorithm (GA). The results demonstrate the validation, applicability and effectiveness of using the MPA for solving multi-region OPF problem considering renewable energy sources and load variability.
29 November 2011 in IEEE Transactions on Power Delivery
This paper develops and presents the steady-state, fundamental-frequency model of the single-phase distributed energy resource (DER) unit which utilizes a single-phase voltage-sourced converter (VSC) as the interface medium. The model represents: 1) different operating and control modes and 2) the operational constraints and limits of the VSC and the host grid. The model is included in a sequential power-flow analysis method using: 1) a backward-forward sweep algorithm for single-phase laterals and 2) a sequence-components frame solver for three-phase networks. The interface-VSC operating limits are accommodated in the power-flow algorithm as an interleaved step to increase computational efficiency of the power-flow analysis tool. Case studies are conducted to evaluate and verify 1) the accuracy of the proposed model and 2) the computational efficiency of the power-flow algorithm.