Vanessa Barton

Vanessa Barton

Auto-generated profile, based on publicly available information

Vanessa Barton

Department of Mechanical Engineering University of Wisconsin‐Madison Madison WI 53706 USA

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2025 in Advanced Materials Technologies
Verified
Journal Article
Open access
SCSinan Candan
Sinan Candan
VBVanessa Barton
Vanessa Barton
HYHaocheng Yang
Haocheng Yang
CLClaudia‐F López‐Cámara
Claudia‐F López‐Cámara
PFPaolo Fortugno
Paolo Fortugno
CFChristian Franck
Christian Franck
Many applications in human health screening, soft robotics, and structural health monitoring require sensors that can accommodate large deformations and highly curved geometries, while providing reliable measurements across a range of frequencies. Ideally, such sensors will also be low cost and easy to manufacture. While prior studies achieve some of these goals, it is rare to achieve them all in a holistic manner. Here, a soft sensor that is easy to manufacture, affordable, and water compatible is presented. The sensor is made of a combination of carbon nanotubes and few‐layer graphene dispersed in a polydimethylsiloxane elastomer. The sensor's ability to detect a broad range of frequencies under both uniaxial stretch and bending is demonstrated. The sensor is effective in multiple configurations, including directly stretching the sensor, adhering the sensor to a deforming compliant substrate, and operating under water. Specifically, the sensor can accurately detect vibrational frequencies with amplitudes as small as 0.1% strain and excitation frequencies covering a broad range of 50–600 Hz with an average root mean square error (RMSE) of 0.16%. Even in the presence of large (≈ 20%) deformations and aqueous environments the sensor can recover the fundamental and higher order vibrational modes within less than 2% error.

14 January 2026 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
VBVanessa Barton
Vanessa Barton
HTHridyesh Tewani
Hridyesh Tewani
XSXiangyu Sun
Xiangyu Sun
CFChristian Franck
Christian Franck
PPPavana Prabhakar
Pavana Prabhakar
Joseph AndrewsJoseph Andrews
Joseph Andrews

8 August 2024 in Research Square
Verified
Preprint
Open access
PDF file
Joseph AndrewsJoseph Andrews
Joseph Andrews
VBVanessa Barton
Vanessa Barton
HTHridyesh Tewani
Hridyesh Tewani
XSXiangyu Sun
Xiangyu Sun
CFChristian Franck
Christian Franck
PPPavana Prabhakar
Pavana Prabhakar
Flexible pressure sensors have a wide range of applications including human body monitoring and robotic control. Recent work has focused on developing pressure sensors that excel at measuring pressure in the ultrasensitive range, often with parallel plate piezocapacitive sensors and a dielectric that relies on microstructures. However, these approaches have a few drawbacks including a limited range and high complexity leading to expensive and time-consuming manufacturing. To mitigate these problems, we demonstrate the fabrication of a low-cost, flexible, interdigitated electrode (IDE) pressure sensor with an overlaid layered elastomer composed of polydimethylsiloxane (PDMS) and Barium Titanate (BaTiO3). The elastomers are manipulated by modifying the mixing ratio, curing temperature, incorporation of BaTiO3, and compressed at two strain rates. Characterization of these elastomers and IDE geometry allows for insights into the behavior and tunability of the layered macrostructure and electrode design. As a result, the leading IDE geometry can be tuned to work in a lower range with a sensitivity of 77.8% per decade between 0 and 10 kPa and 4.5% per decade between 10 and 100 kPa or in a larger range with a sensitivity of 12.9% per decade between 0 and 100 kPa and 3.4% per decade between 100 and 500kPa.