Yu-Min Chang

Yu-Min Chang

Auto-generated profile, based on publicly available information

Yu-Min Chang

From the Department of Ophthalmology (Y.M.C., K.H.C.), Tri-Service General Hospital; and School of Medicine, National Defense Medical University, Taipei, Taiwan

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2017 in Environmental Progress & Sustainable Energy
Verified
Journal Article
Closed access
PDF file
Kae-Long LinKae-Long Lin
Kae-Long Lin
KLKang-Wei Lo
Kang-Wei Lo
MHMing-Jui Hung
Ming-Jui Hung
CHChao‐Lung Hwang
Chao‐Lung Hwang
TCTa-Wui Cheng
Ta-Wui Cheng
YCYu‐Min Chang
Yu‐Min Chang

1 July 1992 in Waste Management & Research: The Journal for a Sustainable Circular Economy
Verified
Journal Article
Closed access
YCYu-Min Chang
Yu-Min Chang
JKJung-Shing Kang
Jung-Shing Kang
CHChin-Chen Ho
Chin-Chen Ho
A pilot scale test facility of a circulating fluidized bed incinerator was established to generate design and operation data and help assess the technical feasibility for industrial applications. The use of high turbulence in the combustion zone and feeding an acid-capturer directly into the incinerator to absorb acid gases eliminates the costly afterburner and scrubber. This paper presents some systematic incineration tests of uniform industrial wastes such as paper mill sludge cake, rubber waste and petroleum coke. Sludge cakes with high moisture and low heating values can be treated to a low emission level by co-firing with coal. The high superficial gas velocity has improved combustion efficiency but increases NOx emissions. However, sulphur content has almost no influence on sulphur retention. The problems of CO/NOx emissions and circulation stability are also discussed.

4 April 2024 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
WYWei-Ting Yen
Wei-Ting Yen
TWTzu-Heng Weng
Tzu-Heng Weng
TLTing-Yi Lin
Ting-Yi Lin
MTMing-Cheng Tai
Ming-Cheng Tai
YCYi-Hao Chen
Yi-Hao Chen
YCYu-Min Chang
Yu-Min Chang
Aims To compare the refractive and visual outcomes of femtosecond laser-assisted astigmatic keratotomy (FSAK) and toric intraocular lens (IOL) implantation for correcting astigmatism in cataract patients. Methods Studies were retrieved from the Ovid-Medline, EMBASE, Cochrane Central Register of Controlled Trials and Scopus which compared FSAK and toric IOL for astigmatism correction in cataract patients. Outcome measures included postoperative refractive cylinder, correction index, uncorrected distance visual acuity (UDVA), the proportion of patients achieving a residual refractive cylinder of 1.00 dioptre or less, target-induced astigmatism (TIA) and surgically induced astigmatism (SIA). The trial sequential analysis (TSA) was used to collect firm evidence supporting our conclusion. Results 9 studies encompassing 590 participants were analysed. The meta-analysis revealed that toric IOLs could result in less postoperative refractive cylinder and provide better UDVA compared with FSAK. The TSA disclosed strong evidence of lower postoperative refractive cylinder in the toric IOL group compared with that of the FSAK group. FSAK showed a smaller correction index and lower mean TIA and SIA compared with toric IOLs. Conclusions For cataract patients, both FSAK and toric IOLs are effective methods for correcting astigmatism. However, toric IOLs offer less postoperative astigmatism and result in better postoperative UDVA compared with FSAK. In vector analysis of astigmatism, toric IOLs can also produce higher TIA and SIA. Additionally, neither method is associated with severe untreatable complications. Therefore, the conclusion is that toric IOLs are the preferred choice for astigmatism correction in cataract patients and FSAK serves as a viable alternative when toric IOLs are contraindicated.

23 April 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
YCYu-Min Chang
Yu-Min Chang
JCJiann-Torng Chen
Jiann-Torng Chen
MTMing-Cheng Tai
Ming-Cheng Tai
WCWei-liang Chen
Wei-liang Chen
YCYing Jen Chen
Ying Jen Chen
Background: Uncontrolled intraocular pressure (IOP) plays a principal role in the deterioration of glaucoma, and the intraocular pressure is also accepted as the most important modifiable factor. Calcium ion has been found to play a vital role in regulating the resistance of the trabecular meshwork in humans. However, the relationship between serum total calcium and IOP has not been well-established. Methods: We investigated the association between serum total calcium and the IOP in a large population (14,037 eligible participants, consisting of 7712 men and 6325 women, were included) at the Tri-Service General Hospital from 2010 to 2016. Several models of covariate adjustments associated with IOP were designed. Univariate and multivariate regression analysis was performed for gender differences in the association between the serum total calcium level and IOP. Results: There was a significant relationship between serum total calcium levels and IOP in women and men with a β coefficient of 0.050 (95% confidence interval (CI), 0.030–0.069) and 0.025 (95%CI, 0.007–0.043). Notably, participants in the highest tertiles of serum total calcium levels had significantly higher IOP, in both the male and female participants. Conclusions: Our study shows that IOP is significantly associated with serum total calcium levels in a large Asian population. This study supports the notion that serum total calcium may play an important role in groups at high risk for elevated IOP.

27 June 2025 in Eye & Contact Lens: Science & Clinical Practice
Verified
Journal Article
Open access
TWTzu-Heng Weng
Tzu-Heng Weng
Wen-Pin LinWen-Pin Lin
Wen-Pin Lin
TLTing-Yi Lin
Ting-Yi Lin
MTMing-Cheng Tai
Ming-Cheng Tai
Ke-Hung ChienKe-Hung Chien
Ke-Hung Chien
YCYu-Min Chang
Yu-Min Chang
Objectives: To evaluate the impact of a new orthokeratology (OrthoK) lens on corneal epithelial thickness and higher-order aberrations (HOAs). Methods: This three-arm, prospective, crossover study randomly assigned participants to the control group, T1 group (1.5× control-group lens-design reverse curve [RC] height), and T2 group (2× control-group lens-design RC height). Participants underwent basic ophthalmological examinations, corneal topography, and corneal epithelial thickness and HOA measurements at each visit. Corneal zones were analyzed based on topographic changes induced by lens wear, corresponding to the central treatment zone and the reverse zone. Results: The spherical equivalent was significantly lower in T1 and T2 than in the control group on days 7 and 28 of lens wear (P<0.001). The corneal curvature was noticeably flatter in T1 and T2 than in the control group. No significant differences were observed among groups in the epithelial thickness of the central treatment zone after OrthoK lens wear. However, epithelial thickness in the reverse zone was significantly greater (P<0.05) in T1 and T2 compared with the control group after 28 days of lens wear. A significant difference in HOA was observed among the three groups after OrthoK lens wear for 1 and 7 days (P<0.01). T2 demonstrated higher levels of HOA than the other groups. Conclusions: This new design of OrthoK can alter the corneal epithelium thickness and stabilize central corneal flattening, thereby achieving a better correction for myopia. However, this design also induces HOAs and is associated with a mild but significant compromise in uncorrected visual acuity compared with conventional designs. Therefore, clinicians should weigh the potential benefits of myopia control against the associated effects on visual quality when selecting OrthoK lens designs.

5 December 2025 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
YCYu-Min Chang
Yu-Min Chang
KCKe-Hung Chien
Ke-Hung Chien
CWChi-Jung Wu
Chi-Jung Wu