13 September 2022 in Journal of Cleaner Production
18 July 2020 in Environmental Science and Pollution Research
1 January 2024 in Advances in Civil Engineering
In green energy buildings, air conditioning charges can be lowered through careful planning of the building’s envelope. This article investigates several strategically designed phase change material (PCM) roof envelopes for savings on air conditioning prices, CO2 emission abatement, and payback timeframes in hot–arid and warm‐temperate climates, taking into account unsteady heat transfer characteristics, cooling, and heating degree–hours. This is accomplished by using six different PCMs–RCC (reinforced cement concrete) roof envelope cases (RCC roof with PCM layer on the outer side, RCC roof with PCM layer on the center (middle), RCC roof with PCM layer on the inside, RCC roof with PCM layers placed on the outside and center, RCC roof with PCM layers placed on the center and inside, and RCC roof with PCM layers placed on the outer side and inside) with three PCMs (FS29 (form stable mixture), HS29 (hydrated salt), and OM29 (organic mixture)). PCM thermophysical characteristics are experimentally measured. The analytical results are experimentally validated. In hot–arid and warm‐temperate regions, the layer of PCM installed on the outside of the RCC with HS29 saved the most on air conditioning expenses, at 6.29 and 6.61 $/m2, respectively. They also reported the greatest carbon mitigation of 300.55 kg of CO2/year and 281.58 kg of CO2/year with the faster payback periods. PCM roof envelopes are the most energy‐efficient option for green buildings.
4 November 2019 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
The present investigation focuses on theoretical performance of various new environment-friendly refrigerant mixtures as substitutes to high global warming potential refrigerant R22. In this investigation, 34 refrigerants were considered at various composition. In this work, both complex vapor compression cycle (actual cycle) and standard vapor compression cycle (ideal cycle) was considered for the performance assessment of refrigerants. Vital studies such as flammability, toxicity, and environmental impact of various novel refrigerants were also carried out in this study. Results obtained from actual cycle showed that the coefficient of performance of refrigerant mixture RM40 (R1270/R134a 90/10 in mass %) (2.728) was the greatest among 34 investigated alternatives and it was closer to the coefficient of performance of R22 (2.770). Compressor discharge temperature of RM40 was 13.36 ℃ lower when compared with R22. Volumetric refrigeration capacity of RM40 (3335 kJ/m3) was slightly higher than that of R22 (3297 kJ/m3). Power spent per ton of refrigeration of RM40 (1.288 kW/TR) was marginally higher than that of R22 (1.269 kW/TR). Global warming potential (GWP100) of RM40 (133) was very low compared to the GWP100 of R22 (1760). Total equivalent warming index (environmental impact) of RM40 was 5.61% lower than R22. However, performance results obtained from standard cycle for various investigated refrigerants were better than actual cycle, since various losses occur were neglected in the standard cycle. Overall, thermodynamic performance of refrigerant mixture RM40 (R1270/R134a 90/10 in mass %) obtained from both actual and standard cycle was the highest among 34 investigated refrigerants and it was very closer to the performance of R22 and hence, it could be considered as an environment-friendly alternative to replace high GWP refrigerant R22 used in refrigeration systems.
31 March 2019 in International Journal of Heat and Technology
28 September 2019 in International Journal of Heat and Technology