15 December 2020 in Physical Review E
We propose a mechanism to generate a single intense circularly polarized attosecond x-ray pulse from the interaction of a circularly polarized relativistic few-cycle laser pulse with an ultrathin foil at normal incidence. Analytical modeling and particle-in-cell simulation demonstrate that a huge charge-separation field can be produced when all the electrons are displaced from the target by the incident laser, resulting in a high-quality relativistic electron mirror that propagates against the tail of the laser pulse. The latter is efficiently reflected as well as compressed into an attosecond pulse that is also circularly polarized.
5 April 2024 in Science Advances
The origin of the cosmic magnetic field remains an unsolved mystery, relying not only on specific dynamo processes but also on the seed field to be amplified. Recently, the diffuse radio emission and Faraday rotation observations reveal that there has been a microgauss-level magnetic field in intracluster medium in the early universe, which places strong constraints on the strength of the initial field and implies the underlying kinetic effects; the commonly believed Biermann battery can only provide extremely weak seed of 10 −21 G. Here, we present evidence for the spontaneous Weibel-type magnetogenesis in laser-produced weakly collisional plasma with the three-dimensional synchronous proton radiography, where the distribution anisotropy directly arises from the temperature gradient, even without the commonly considered interpenetrating plasmas or shear flows. This field can achieve sufficient strength and is sensitive to Coulomb collision. Our results demonstrate the importance of kinetics in magnetogenesis in weakly collisional astrophysical scenarios.
1 February 2018 in Physics of Plasmas
Coherent synchrotron emission (CSE) from relativistic near-critical-density (NCD) plasmas irradiated by a few-cycle laser pulse is investigated theoretically and numerically. Due to the unique and larger laser-plasma interaction region in relativistic NCD plasmas, compared to those in solid targets, not only the required stringent conditions for CSE on laser and target are relaxed but also the radiation intensities are enhanced by two orders of magnitude. Moreover, it is found that a single attosecond pulse can also be easily obtained in the transmitted direction through CSE in this regime. Its energy conversion efficiencies from laser to emission can reach 10−3–10−2, which is more than one order of magnitude larger than those of attosecond trains from solids. Two-dimensional particle-in-cell simulations show that an intense single pulse at a peak intensity of ∼1019 W/cm2 and duration of ∼98 as in the transmitted direction is produced by the drive laser at an intensity of I0 = 8.6 × 1020 W/cm2.
3 January 2024 in Nuclear Fusion
Experiments and simulations have been carried out to study the colliding process by two lasers irradiating a gold half-hohlraum. Via analyzing the evolutionary x-ray images, radiation fluxes and self-emission spectrum of tracers, influence on the x-ray conversion efficiency and the local plasma temperature from two gold-plasma plumes have been investigated deeply, which is similar as the configuration in Inertial Confinement Fusion (ICF). Experimental results confirm a region with high electron and ion temperatures are induced, satisfying the strong collision condition of , where λ
i
and are respectively the ion mean-free path and the gradient length of Te
. It leads to almost increasing of M-band component compared to that from a single laser-irradiation case. Meanwhile ion temperature in this region increases more rapidly than electrons, reaching about keV ( keV). Thus, our studies provide the experimental evidence of quantitative x-ray enhancement and a non-equilibrium evolution simultaneously due to the plasma collision for the first time. Besides, two-dimensional simulation results reveal that this process can not be precisely described by the traditional shock-heating model by dissipating the shock energy only to ions. But by distributing the viscous heating between both electrons and ions as theoretically discussed by Miller (2020 Comput. Fluids 210 104672), numerical results can match experiments better. This discovery will be of great importance to improve the precision of prediction for ICF.
28 November 2024 in Nuclear Fusion
In indirect-drive inertial confinement fusion (ICF) research, the meticulous design and optimization of laser parameters are crucial for achieving high-gain ignition. The intensity of the toe laser, used for ablating the hohlraum sealing membrane, is a subtle but equally critical parameter. This study introduces a novel experimental approach using the Velocity Interferometer System for Any Reflector (VISAR) to assess the impact of toe laser intensity on the compression of fusion capsules. By tracking the reflectivity of tracer layers and shock velocities in liquid deuterium, the adverse effects of insufficient toe laser intensity on capsule compression have been unveiled for the first time. From a comparison with hydrodynamic simulations, we show that below a critical threshold of 0.23 × 1014 W cm−2, the adiabat, a measure of the fuel’s compression efficiency, increases markedly with the toe laser intensity decreases, whereas it remains stable within the range of (0.23 ∼ 7) × 1014 W cm−2. Our findings provide critical insights on toe laser parameter design, enhancing our understanding of the role of toe laser intensity in ICF experiments. This research not only refines the parameters for laser operation but also underscores the importance of precision in achieving the desired implosion efficiency, contributing to the development of nuclear fusion as a clean energy source.
1 June 2021 in Physics of Plasmas
Great efforts have been made to create a bright K-shell source using the thin metal cylindrical cavities in the past few decades. Several metal materials such as titanium (Ti), iron, and so on have been tested for high x-ray conversion efficiency mainly at the OMEGA and NIF laser facilities. Recently, x-ray sources in Ti K-shell transition energy range were investigated at the Shenguang-III prototype laser facility with ∼5 kJ laser energy. The experiments were aimed to reproduce the previous ones at OMEGA, but with an extraordinarily small volume of cylindrical cavity and detailed characterizations of the x-ray source. The cavities were 800 μm inner diameter, 800 μm length, and 30 μm thick plastic tubes supporting 1 μm thick Ti. Seven laser beams were focused to 200 μm diameter. The combination of the small cavity volume and the focused laser spots is intended to improve the electron temperature with limited laser energy since the electron temperature is a key issue for high x-ray conversion efficiency. Thomson scattering was adopted to experimentally probe the electron temperatures at special time and space zones as well as the average temperature obtained from the Ti K-shell spectrum. The evolutions of the electron temperature and density are predicted by the radiation hydrodynamic simulation. A top view and two photon energy bands of x-ray source images provide a way to directly observe the plasma movement toward the cavity axis and distinguish the different emission mechanisms between the Ti K-shell and lower energy x rays. Six Higher-energy x-ray detectors located at different angles were used to record the Ti K-shell x-ray emission and demonstrate its isotropic feature. The characteristics of the x-ray radiate intensity including the time evolution, the angular distribution, and the total yields for both the photon energy regions above and below 4 keV are compared between the cavity and planar targets. Obviously, different behaviors were found between the two photon energy regions and the two types of targets. The x-ray conversion efficiency of the Ti cylinder was determined to be and in sr in the Ti K-shell (4–7 keV) and <4 keV range, respectively. The Ti K-shell conversion efficiency obtained in the present experiments is between the ones driven by 13.5 and 4.5 kJ laser energy at OMEGA.