17 January 2017 in Journal of Earthquake Engineering
The concept of providing a fuse in a structural system has been both developed and investigated over the past few years (e.g., the use of replaceable links in eccentrically braced frames or the use of replaceable links in the new San Francisco-Oakland Bay Bridge). This paper presents a new coupling beam with a creative fuse installed in the mid-span of a steel-concrete composite beam via an end plate and high-strength bolts. First, a practical design methodology of a replaceable coupling beam is presented. Next, the seismic behavior of the proposed fuse is tested and evaluated, and two structural wall specimens with or without a fuse are designed and fabricated according to the proposed design methods. The two specimens possess similar shear capacities under large-scale cyclic loading, and the walls of the two specimens show similar failure modes; however, the new walls exhibit slightly lower levels of damage than the conventional walls. In particular, the inelastic deformation and damage of replaceable coupling beams are mainly concentrated in the fuse, whereas the non-yield segment and the beam-wall pier interfaces remain nearly intact and produce only slight damage, which is beneficial regarding the replacement of the fuse in post-earthquake events.
1 August 2021 in Engineering Structures
16 June 2022 in Journal of Earthquake Engineering
A resilient rocking steel column base (RRSCB) installed with composite combination disc spring (CCDS) is proposed in this paper. The restoring force model and energy calculation formulae of the RRSCB are derived by the theoretical analyses and energy conservation law, respectively. A refined finite element model validated by the cyclic loading tests is established with the aid of ABAQUS to investigate the seismic performance of the RRSCB. The results indicate that the RRSCB possesses satisfactory self-centering capability and desirable energy dissipation capacity for the design displacement. The established restoring force model and energy calculation formulae can reasonably predict the hysteretic behavior of RRSCB under cyclic loading.
1 January 2025 in Structural Control and Health Monitoring
This study proposes a novel mechanical parameter design methodology for graded‐yield dampers based on an enhanced genetic algorithm framework, accompanied by comprehensive design procedures and algorithmic flow diagrams. The proposed approach employs genetic algorithm optimization to determine optimal yield displacement and yield bearing capacity parameters for single yield‐point metallic dampers under three seismic intensity levels (small, moderate and large earthquakes). These optimized parameters are subsequently utilized to construct quadrilinear skeleton curves for three‐stage graded‐yield dampers. Distinct hysteretic models are developed according to the energy dissipation characteristics of two damper configurations: non‐gap annular‐type and reserved‐gap‐type graded‐yield dampers. A comparative analysis of vibration control performance reveals that both damper configurations demonstrate significant energy dissipation capabilities. The reserved‐gap configuration exhibits superior energy dissipation efficiency compared to its non‐gap counterpart. Gap‐type dampers achieve better interstory drift control across all seismic intensities, particular in frequent earthquakes. Acceleration response mitigation shows marked improvement in both graded‐yield systems. These findings provide critical theoretical insights for application and research of different types of graded‐yield dampers.