Yun Chen

Yun Chen

Auto-generated profile, based on publicly available information

Yun Chen

School of Civil Engineering & Architecture Hainan University Haikou China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2017 in Journal of Earthquake Engineering
Verified
Journal Article
Closed access
XLXilin Lu
Xilin Lu
YCYun Chen
Yun Chen
HJHuanjun Jiang
Huanjun Jiang
The concept of providing a fuse in a structural system has been both developed and investigated over the past few years (e.g., the use of replaceable links in eccentrically braced frames or the use of replaceable links in the new San Francisco-Oakland Bay Bridge). This paper presents a new coupling beam with a creative fuse installed in the mid-span of a steel-concrete composite beam via an end plate and high-strength bolts. First, a practical design methodology of a replaceable coupling beam is presented. Next, the seismic behavior of the proposed fuse is tested and evaluated, and two structural wall specimens with or without a fuse are designed and fabricated according to the proposed design methods. The two specimens possess similar shear capacities under large-scale cyclic loading, and the walls of the two specimens show similar failure modes; however, the new walls exhibit slightly lower levels of damage than the conventional walls. In particular, the inelastic deformation and damage of replaceable coupling beams are mainly concentrated in the fuse, whereas the non-yield segment and the beam-wall pier interfaces remain nearly intact and produce only slight damage, which is beneficial regarding the replacement of the fuse in post-earthquake events.


7 February 2019 in Sustainability
Verified
Journal Article
Open access
PDF file
YCYun Chen
Yun Chen
JLJunzuo Li
Junzuo Li
Zheng  LuZheng Lu
Zheng Lu
The coupled shear wall with replaceable coupling beams is a current research hotspot, while still lacking comprehensive studies that combine both experimental and numerical approaches to describe the global performance of the structural system. In this paper, hybrid coupled shear walls (HSWs) with replaceable coupling beams (RCBs) are studied. The middle part of the coupling beam is replaced with a replaceable “fuse”. Four ½-scale coupled shear wall specimens including a conventional reinforced concrete shear wall (CSW) and three HSWs (F1SW/F2SW/F3SW) with different kinds of replaceable “fuses” (Fuse 1/Fuse 2/Fuse 3) are tested through cyclic loading. Fuse 1 is an I-shape steel with a rhombic opening at the web; Fuse 2 is a double-web I-shape steel with lead filled in the gap between the two webs; Fuse 3 consists of two parallel steel tubes filled by lead. The comparison of seismic properties of the four shear walls in terms of failure mechanism, hysteretic response, strength degradation, stiffness degradation, energy consumption, and strain response is presented. The nonlinear finite element analysis of four shear walls is conducted by ABAQUS software. The deformation process, yielding sequence of components, skeleton curves, and damage distribution of the walls are simulated and agree well with the experimental results. The primary benefit of HSWs is that the damage of the coupling beam is concentrated at the replaceable “fuse”, while other parts remain intact. Besides, because the “fuse” can dissipate much energy, the damage of the wall-piers is also alleviated. In addition, among the three HSWs, F1SW possesses the best ductility and load retention capacity while F2SW possesses the best energy dissipation capacity. Based on this comprehensive study, some suggestions for the conceptual design of HSWs are further proposed.

16 June 2022 in Journal of Earthquake Engineering
Verified
Journal Article
Closed access
YCYun Chen
Yun Chen
YWYuanhang Wei
Yuanhang Wei
CCChao Chen
Chao Chen
MZMing Zhang
Ming Zhang
A resilient rocking steel column base (RRSCB) installed with composite combination disc spring (CCDS) is proposed in this paper. The restoring force model and energy calculation formulae of the RRSCB are derived by the theoretical analyses and energy conservation law, respectively. A refined finite element model validated by the cyclic loading tests is established with the aid of ABAQUS to investigate the seismic performance of the RRSCB. The results indicate that the RRSCB possesses satisfactory self-centering capability and desirable energy dissipation capacity for the design displacement. The established restoring force model and energy calculation formulae can reasonably predict the hysteretic behavior of RRSCB under cyclic loading.

1 January 2025 in Structural Control and Health Monitoring
Verified
Journal Article
Open access
YCYun Chen
Yun Chen
GGGan Guo
Gan Guo
YZYunlong Zheng
Yunlong Zheng
RDRui Dai
Rui Dai
This study proposes a novel mechanical parameter design methodology for graded‐yield dampers based on an enhanced genetic algorithm framework, accompanied by comprehensive design procedures and algorithmic flow diagrams. The proposed approach employs genetic algorithm optimization to determine optimal yield displacement and yield bearing capacity parameters for single yield‐point metallic dampers under three seismic intensity levels (small, moderate and large earthquakes). These optimized parameters are subsequently utilized to construct quadrilinear skeleton curves for three‐stage graded‐yield dampers. Distinct hysteretic models are developed according to the energy dissipation characteristics of two damper configurations: non‐gap annular‐type and reserved‐gap‐type graded‐yield dampers. A comparative analysis of vibration control performance reveals that both damper configurations demonstrate significant energy dissipation capabilities. The reserved‐gap configuration exhibits superior energy dissipation efficiency compared to its non‐gap counterpart. Gap‐type dampers achieve better interstory drift control across all seismic intensities, particular in frequent earthquakes. Acceleration response mitigation shows marked improvement in both graded‐yield systems. These findings provide critical theoretical insights for application and research of different types of graded‐yield dampers.

19 July 2025 in Buildings
Verified
Journal Article
Open access
PDF file
JLJianjun Li
Jianjun Li
LSLvhong Sun
Lvhong Sun
YWYanchao Wu
Yanchao Wu
YCYun Chen
Yun Chen
DQDengzhou Quan
Dengzhou Quan
SDSansheng Dong
Sansheng Dong
A numerical investigation is conducted to examine the mechanical properties of a novel three-dimensional (3D) isolation bearing. This device is primarily composed of a lead rubber bearing (LRB), disc springs, and U-shaped dampers. A finite element model is developed and validated against the previous experimental results. Subsequently, comprehensive analyses are performed to evaluate the influence of vertical loadings, shear strains, and the number of U-shaped dampers on the horizontal behavior, as well as the effects of displacement amplitudes and the number of dampers on the vertical performance. Under horizontal loading conditions, the bearing demonstrates reliable energy dissipation capabilities. However, the small lead core design limits its energy dissipation capacity. Compared with the bearing without U-shaped dampers, the bearing’s energy dissipation capacity increases by 628%, 1300%, and 2581% when employing 1, 2, and 4 dampers on each side, respectively. Regarding vertical performance, the innovative disc spring group design effectively reduces the tensile displacement of the LRB under tension, thereby enhancing the overall tensile capacity of the bearing. Furthermore, in comparison to their contribution to horizontal energy dissipation, the U-shaped dampers play a relatively minor role in vertical energy dissipation.