Nadine N. Graedel

Nadine N. Graedel

Auto-generated profile, based on publicly available information

Nadine N. Graedel

Department of Imaging Neuroscience, UCL Queen Square Institute of Neurology, University College London, London, UK

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2025 in Science Advances
Verified
Journal Article
Open access
OWOliver Warrington
Oliver Warrington
NGNadine N. Graedel
Nadine N. Graedel
MCMartina F. Callaghan
Martina F. Callaghan
PKPeter Kok
Peter Kok
Current evidence suggests that the hippocampus is essential for exploiting predictive relationships during perception. However, it remains unclear whether the hippocampus drives the communication of predictions to sensory cortex or receives prediction signals from elsewhere. We collected 7-tesla fMRI data in the medial temporal lobe (MTL) while auditory cues predicted abstract shapes. Strikingly, neural patterns evoked by predicted shapes in CA2/3, pre/parasubiculum, and the parahippocampal cortex (PHC) were negatively correlated to patterns evoked by the same shapes when actually presented. Using layer-specific analyses, we ask: In which direction are predictions communicated between the hippocampus and neocortex? Superficial layers of the MTL cortex project to the hippocampus, while the deep layers receive feedback projections. Informational connectivity analyses revealed that communication between CA2/3 and PHC was specific to the deep layers of PHC. These findings suggest that the hippocampus generates predictions through pattern completion in CA2/3 and feeds these predictions back to the neocortex.

28 July 2023 in NeuroImage
Verified
Journal Article
Open access
VMVahid Malekian
Vahid Malekian
NGNadine N Graedel
Nadine N Graedel
AHAlice Hickling
Alice Hickling
AAAli Aghaeifar
Ali Aghaeifar
BDBarbara Dymerska
Barbara Dymerska
MCMartina F. Callaghan
Martina F. Callaghan
Geometric distortion is a major limiting factor for spatial specificity in high-resolution fMRI using EPI readouts and is exacerbated at higher field strengths due to increased B0 field inhomogeneity. Prominent correction schemes are based on B0 field-mapping or acquiring reverse phase-encoded (reversed-PE) data. However, to date, comparisons of these techniques in the context of fMRI have only been performed on 2DEPI data, either at lower field or lower resolution. In this study, we investigate distortion compensation in the context of sub-millimetre 3DEPI data at 7T. B0 field-mapping and reversed-PE distortion correction techniques were applied to both partial coverage BOLD-weighted and whole brain MT-weighted 3DEPI data with matched distortion. Qualitative assessment showed overall improvement in cortical alignment for both correction techniques in both 3DEPI fMRI and whole-brain MT-3DEPI datasets. The distortion-corrected MT-3DEPI images were quantitatively evaluated by comparing cortical alignment with an anatomical reference using dice coefficient (DC) and correlation ratio (CR) measures. These showed that B0 field-mapping and reversed-PE methods both improved correspondence between the MT-3DEPI and anatomical data, with more substantial improvements consistently obtained using the reversed-PE approach. Regional analyses demonstrated that the largest benefit of distortion correction, and in particular of the reversed-PE approach, occurred in frontal and temporal regions where susceptibility-induced distortions are known to be greatest, but had not led to complete signal dropout. In conclusion, distortion correction based on reversed-PE data has shown the greater capacity for achieving faithful alignment with anatomical data in the context of high-resolution fMRI at 7T using 3DEPI.

4 July 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
NGNadine N. Graedel
Nadine N. Graedel
KMKarla L. Miller
Karla L. Miller
MCMark Chiew
Mark Chiew
Purpose: We investigate the use of TURBINE, a 3D radial‐Cartesian acquisition scheme in which EPI planes are rotated about the phase‐encoding axis to acquire a cylindrical k‐space for high‐fidelity ultrahigh isotropic resolution fMRI at 7 Tesla with minimal distortion and blurring.Methods: An improved, completely self‐navigated version of the TURBINE sampling scheme was designed for fMRI at 7 Telsa. To demonstrate the image quality and spatial specificity of the acquisition, thin‐slab visual and motor BOLD fMRI at 0.67 mm isotropic resolution (16 mm slab, TRvol = 2.32 s), and 0.8 × 0.8 × 2.0 mm (whole‐brain, TRvol = 2.4 s) data were acquired. To prioritize the high spatial fidelity, we employed a temporally regularized reconstruction to improve sensitivity without any spatial bias.Results: TURBINE images provide high structural fidelity with almost no distortion, dropout, or T2* blurring for the thin‐slab acquisitions compared to conventional 3D EPI owing to the radial sampling in‐plane and the short echo train used. This results in activation that can be localized to pre‐ and postcentral gyri in a motor task, for example, with excellent correspondence to brain structure measured by a T1‐MPRAGE. The benefits of TURBINE (low distortion, dropout, blurring) are reduced for the whole‐brain acquisition due to the longer EPI train. We demonstrate robust BOLD activation at 0.67 mm isotropic resolution (thin‐slab) and also anisotropic 0.8 × 0.8 × 2.0 mm (whole‐brain) acquisitions.Conclusion: TURBINE is a promising acquisition approach for high‐resolution, minimally distorted fMRI at 7 Tesla and could be particularly useful for fMRI in areas of high B0 inhomogeneity.

20 May 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
EAEva Alonso‐Ortiz
Eva Alonso‐Ortiz
DPDaniel Papp
Daniel Papp
RBRobert L. Barry
Robert L. Barry
KPKyota Poëti
Kyota Poëti
ASAlan C. Seifert
Alan C. Seifert
JCJulien Cohen‐Adad
Julien Cohen‐Adad
Purpose: The depth within the body, small diameter, long length, and varying tissue surrounding the spinal cord impose specific considerations when designing RF coils. The optimal coil configuration for 7 T cervical spinal cord MRI is unknown and currently there are very few coil options. The purpose of this work was (1) to establish a quality control protocol for evaluating 7 T cervical spinal cord coils, and (2) to use that protocol to evaluate the performance of four different coil designs.Methods: Three healthy volunteers and a custom anthropomorphic phantom (the traveling spines cohort) were scanned at seven 7 T imaging centers using a common protocol and each center's specific cervical spinal cord coil. Four different coil designs were tested (two in‐house, one Rapid Biomedical, and one MRI.TOOLS design).Results: The Rapid Biomedical coil was found to have the highest efficiency, whereas one of the in‐house designs (NeuroPoly Lab) had the highest SNR and the largest spinal cord coverage. The MRI.TOOLS coil had the most uniform profile along the cervical spinal cord; however, it was limited in its ability to provide the requested flip angles (especially for larger individuals). The latter was also the case for the second in‐house coil (MSSM).Conclusion: The results of this study serve as a guide for the spinal cord MRI community in selecting the most suitable coil based on specific requirements and offer a standardized protocol for assessing future coils.

31 March 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
OWOliver Warrington
Oliver Warrington
NGNadine N. Graedel
Nadine N. Graedel
MCMartina F. Callaghan
Martina F. Callaghan
PKPeter Kok
Peter Kok
Current evidence points to the hippocampus as an essential region coordinating learning and exploiting predictive relationships in the service of perception. However, it remains unclear whether the hippocampus drives the communication of predictions to the sensory cortex or acts as a recipient of predictions from else-where. Here, we collected sub-millimetre 7T fMRI data to investigate neural signals in the medial temporal lobe (MTL). We used layer-specific fMRI to infer the direction of communication between the hippocam-pus and cortex. Specifically, superficial layers of the MTL cortex project to the hippocampus, while deep MTL layers receive feedback projections. Participants performed a task in which auditory cues predicted abstract shapes. Crucially, we omitted the expected shape on 25% of trials, thus isolating the prediction signal from bottom-up input and allowing us to ask: In which direction are predictions communicated between the hippocampus and neocortex? Neural patterns in CA23, pre/parasubiculum and the parahippocampal cortex (PHC) reflected shape-specific predictions. Layer-specific informational connectivity analyses revealed that communication between CA23 and PHC was specific to the deep layers of PHC. These findings are in line with the hippocampus generating predictions through pattern completion in CA23 and feeding these pre-dictions back to the neocortex.

15 October 2019 in bioRxiv
Verified
Preprint
Open access
PDF file
NGNadine N. Graedel
Nadine N. Graedel
LKLars Kasper
Lars Kasper
MEMaria Engel
Maria Engel
JNJennifer Nussbaum
Jennifer Nussbaum
BWBertram J. Wilm
Bertram J. Wilm
SVSigne Johanna Vannesjo
Signe Johanna Vannesjo
Spiral imaging is very well suited for functional MRI, however its use has been limited by the fact that artifacts caused by gradient imperfections and B 0 inhomogeneity are more difficult to correct compared to EPI. Effective correction requires accurate knowledge of the traversed k-space trajectory. With the goal of making spiral fMRI more accessible, we have evaluated image reconstruction using trajectories predicted by the gradient impulse response function (GIRF), which can be determined in a one-time calibration step. GIRF-predicted reconstruction was tested for high-resolution (0.8 mm) fMRI at 7T. Image quality and functional results of the reconstructions using GIRF-prediction were compared to reconstructions using the delay-corrected nominal trajectory and concurrent field monitoring. The reconstructions using nominal spiral trajectories contain substantial artifacts and the activation maps contain misplaced activation. Image artifacts are substantially reduced when using the GIRF-predicted reconstruction, and the activation maps for the GIRF-predicted and monitored reconstructions largely overlap. The GIRF reconstruction provides a large increase in the spatial specificity of the activation compared to the nominal reconstruction. The GIRF-reconstruction generates image quality and fMRI results similar to using a concurrently monitored trajectory. The presented approach does not prolong or complicate the fMRI acquisition. Using GIRF-predicted trajectories has the potential to enable high-quality spiral fMRI in situations where concurrent trajectory monitoring is not available. Highlights: This work investigates the feasibility of using a one-time system calibration to account for k-space trajectory deviations in spiral fMRI. This versatile calibration is based on a linear time-invariant gradient model, the gradient impulse response function (GIRF). We show that the image quality and the spatial specificity of the fMRI activation are substantially improved when using the GIRF-predicted trajectories. Basing reconstructions on nominal gradient inputs, on the other hand, induces image artifacts and misplaced fMRI activation. We demonstrate that system characterization via the GIRF can enable spiral fMRI in situations where concurrent trajectory monitoring is unavailable.