17 January 2018 in Applied Optics
We have developed methods to measure the directional-hemispherical () and diffuse () reflectances of powders, liquids, and disks of powders and solid materials using a commercially available, matte gold-coated integrating sphere and Fourier transform infrared spectrometer. To determine how well the sphere and protocols produce quantitative reflectance data, measurements were made of three diffuse and two specular standards prepared by the National Institute of Standards and Technology (NIST), LabSphere Infragold and Spectralon standards, hand-loaded sulfur and talc powder samples, and water. Relative to the NIST measurements of the NIST standards, our directional hemispherical reflectance values are within for four of the standards and within for a low reflectance diffuse standard. For the three diffuse reflectance NIST standards, our diffuse reflectance values are within of the NIST values. For the two specular NIST standards, our diffuse reflectance values are an order of magnitude larger than those of NIST, pointing to a systematic error in the manner in which diffuse reflectance measurements are made for specular samples using our methods and sphere. Sources of uncertainty are discussed in the paper.
1 November 2010 in Journal of Quantitative Spectroscopy and Radiative Transfer
16 March 2012 in The Journal of Physical Chemistry A
8 July 2000 in The Journal of Chemical Physics
1 March 2017 in Journal of Molecular Spectroscopy
13 September 2012 in International Journal of Spectroscopy
Raman spectroscopy has been shown to be a viable method for explosives detection. Currently most forensic Raman systems are either large, powerful instruments for laboratory experiments or handheld instruments for in situ point detection. We have chosen to examine the performance of certain benchtop Raman probe systems with the goal of developing an inexpensive, portable system that could be used to operate in a field forensics laboratory to examine explosives-related residues or samples. To this end, a rugged, low distortion line imaging dispersive Raman spectrograph was configured to work at 830 nm laser excitation and was used to determine whether the composition of thin films of plastic explosives or small (e.g., ≤10 μm) particles of RDX or other explosives or oxidizers can be detected, identified, and quantified in the field. With 300 mW excitation energy, concentrations of RDX and PETN can be detected and reconstructed in the case of thin Semtex smears, but further work is needed to push detection limits of areal dosages to the ~1 μg/cm2 level. We describe the performance of several probe/spectrograph combinations and show preliminary data for particle detection, calibration and detection linearity for mixed compounds, and so forth.