Abstract-The presence of high-amplitude and specific-frequency magnetic interference in the environment can significantly degrade the signal-to-noise ratio of magnetocardiography (MCG) signal within a magnetically shielded room (MSR), thereby severely impeding the extraction of cardiac magnetic characteristic signal and hindering accurate diagnosis of heart-related diseases. The conventional linear active disturbance rejection control (LADRC) based active magnetic compensation system exhibits limited capability to counteract such interferences, resulting in inadequate suppression effects against high-amplitude and specific-frequency magnetic disturbances in the environment. To address this issue, this paper proposes an active magnetic interference compensation method (LESO-LSEF-PR) that integrates linear extended state observer (LESO), linear state error feedback control law (LSEF), and adaptive proportional resonance control (PR). Comparative analysis with LADRC control approach demonstrates that LESO-LSEF-PR offers superior attenuation performance for high-amplitude and specific-frequency magnetic interferences. Experimental results show that the LESO-LSEF-PR method proposed in this paper can reduce the average magnetic field noise within the 3~40 Hz range of the MSR from 93.05 fT/√Hz to 19.85 fT/√Hz. Compared with the traditional LADRC control method, the noise suppression effect is improved by about 29.7%.
21 February 2025 in IEEE Transactions on Industrial Informatics
The high-amplitude magnetic field interference in the environment causes serious distortion of the cardiac magnetic signal measured in the central area of the magnetic shielding cylinder. The integration of a linear extended state observer (LESO) and a proportional resonance (PR) controller can effectively suppress high-amplitude magnetic interference at specific frequencies. However, the frequency of high-amplitude magnetic interference in the environment is variable, bringing challenges to conventional PR method. To address this issue, this article proposes a novel approach (LESO-AFE-PR) for suppressing magnetic interference by integrating an adaptive frequency estimator (AFE), PR, and LESO. The LESO-AFE-PR method can improve the capability of the active magnetic compensation (AMC) system to attenuate high-amplitude magnetic interference with random frequency. Experimental results show that the LESO-AFE-PR can adaptively track the frequency of magnetic field interference, effectively suppress interference in the range of 1$\sim$40 Hz, and attenuate the amplitude of magnetic field interference from 32.9 to 3.6 pT. Compared to the uncompensated state, a remarkable attenuation of approximately 89$\%$ in magnetic field interference is achieved.
The closed-loop optically pumped magnetometer (CM) is a non-cryogenic sensor with high dynamic range, wide bandwidth, and high sensitivity, and has broad application prospects in the field of cardiac magnetic field measurement. The measurement accuracy of the CM depends on the signal tracking capability of the system. Conventional CM have insufficient tracking capability for quasi-periodic signals. It limits the measurement accuracy of the CM for quasi-periodic signals such as cardiac magnetic field. Based on this problem, a novel method is proposed in this paper. The method introduces parallel multiple second-order generalized integrals (MS) in the proportional integral-cascade extended state observer (PI-CLESO) to enhance the tracking capability of the CM. In the experiment, the CM’s measurement accuracy of the cardiac magnetic field is improved by 70% by the proposed method. This method is not only applicable to the high-precision measurement of the cardiac magnetic field, but also has greater potential for application in the measurement of other quasi-periodic weak magnetic field.
8 May 2025 in IEEE Transactions on Automation Science and Engineering
Multiple frequencies high-amplitude magnetic interference in the environment can adversely affect the detection of cardiac magnetic field signals inside magnetocardiography device. Adaptive multi-resonance control (AMR) is suitable for suppressing such interference, but the stability of active magnetic field compensation system (AMC) will be destroyed by the influence of the time delay of the sensor. To address this problem, this paper proposes a interference suppression method that combines an improved adaptive multi-resonance controller (IAMR) with proportional differential (PD) and linear extended state observer (LESO). Experimental results show that PD-LESO-IAMR can effectively suppress multiple frequencies magnetic interference under the premise of ensuring system stability. Compared with conventional PD-LESO, the average magnetic field interference in the MSC can be reduced from 3.73 pT to 1.80 pT, and the maximum anti-interference ability was increased by 50.25%.