Zhihui Hong

Zhihui Hong

Auto-generated profile, based on publicly available information

Zhihui Hong

Hangzhou Institute of Extremely-Weak Magnetic Field for Major National Science and Technology Infrastructure

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2025 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
PTPengtao Tian
Pengtao Tian
Haifeng ZhangHaifeng Zhang
Haifeng Zhang
ZHZhihui Hong
Zhihui Hong
SZShiqiang Zheng
Shiqiang Zheng
Multiple frequencies high-amplitude magnetic interference in the environment can adversely affect the detection of cardiac magnetic field signals inside magnetocardiography device. Adaptive multi-resonance control (AMR) is suitable for suppressing such interference, but the stability of active magnetic field compensation system (AMC) will be destroyed by the influence of the time delay of the sensor. To address this problem, this paper proposes a interference suppression method that combines an improved adaptive multi-resonance controller (IAMR) with proportional differential (PD) and linear extended state observer (LESO). Experimental results show that PD-LESO-IAMR can effectively suppress multiple frequencies magnetic interference under the premise of ensuring system stability. Compared with conventional PD-LESO, the average magnetic field interference in the MSC can be reduced from 3.73 pT to 1.80 pT, and the maximum anti-interference ability was increased by 50.25%.

14 May 2026 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
DZDi Zhang
Di Zhang
MSminxia shi
minxia shi
Haifeng ZhangHaifeng Zhang
Haifeng Zhang
Jianzhi YangJianzhi Yang
Jianzhi Yang
ZHZhihui Hong
Zhihui Hong
SZShiqiang Zheng
Shiqiang Zheng
Magnetically shielded rooms (MSR) composed of high-permeability materials provided a near-zero magnetic environment for ultra-weak field measurements, such as biomagnetic cardiography and encephalography. To maximise material performance, a demagnetization current is applied to increase the effective permeability, thereby enhancing the shielding performance of the MSR. However, conventional open-loop demagnetization system is susceptible to disturbances that distort the current waveform and degrad the demagnetization effect. To improve disturbance suppression, this paper proposes a closed-loop demagnetization current control strategy that integrates linear quadratic regulator (LQR) with a cascaded extended state observer (CESO). The corresponding demagnetization current control (DCC) system is established on self-developed hardware. Considering the dynamic characteristics of the demagnetization current, the LQR is employed to balance control energy and tracking performance through optimal state feedback. Simultaneously, the CESO is introduced to estimate disturbances online and provide feedforward compensation. Experimental results demonstrated that the proposed LQR-CESO strategy effectively enhanced the disturbance suppression capability of the system. Compared with OPEN-LOOP, the average remanence in the center region of MSR was decreased by 28.8%, and the average shielding factor increased within the range of 1-10 Hz.