25 January 2022 in IEEE Transactions on Nuclear Science
Due to significant radiation hardness, thermal properties, low sensitivity to gamma rays, and fast response, the 4H-SiC detector exhibits promising properties in measuring the neutron production in the high-power fusion devices. To demonstrate the potential value of the 4H-SiC detectors as a neutron flux monitor and a neutron spectrometer on experimentally advanced superconducting tokamak (EAST) during the 2021 EAST deuterium–deuterium plasma experimental campaigns, the 4H-SiC detector covered with a 25- $\mu \text{m}$ -thick 6 LiF film 95% enriched in 6 Li and the 4H-SiC detector covered with a 1.5-mm-thick polyethylene layer were installed on a viewport located at the mid-plane of port F outside the EAST vacuum vessel and operated continuously during the whole experimental campaign with the goal to measure both the total and the time-dependent neutron emission from the plasma. The results are compared with those obtained with detectors routinely working at EAST ( 235 U Fission Chambers). Despite their small active volumes, the 4H-SiC detectors were able to measure the total and the time-dependent neutron emission with good reliability and stability. The results of this work not only demonstrated the satisfactory performance of the 4H-SiC detector in the harsh environment of a mixed neutron–gamma high-radiation field and strong electromagnetic field, but also its applicability as a neutron spectrometer and a neutron flux monitor for fusion deuterium–plasma experiments.
1 July 2024 in IEEE Transactions on Instrumentation and Measurement
In this paper, a trench Schottky barrier diode structure based on a wide band-gap, high temperature and irradiation resistant 4H-SiC material is innovatively proposed, and the neutron conversion material 6 LiF is filled into the trench array to make a neutron detector. The detector increases both the amount of 6 LiF filling and the total contact area between 6 LiF and the semiconductor material 4H-SiC by etching out the trenches. The neutron response experimental study revealed that the count rate of the detector is as high as 580 cps, corresponding to a detection efficiency of 6.57%, which breaks through the limitation that the detection efficiency of thin-film coated type detectors is less than 5%, which is one of the main contributions of the detector. The utilization of refractory metal tungsten (W) as the frontal Schottky contact electrode enables the detector to maintain a count rate of approximately 100 cps at 180 °C, which indicates that there exists a possibility that the detector can work in high temperature environments, and also provides experimental basis for the development of high temperature resistant neutron detectors.
18 November 2024 in IEEE Transactions on Instrumentation and Measurement
In order to meet the demand for neutron detection in extreme environments with high temperature, high pressure and strong radiation, different Schottky-type microstructure neutron detectors based on the wide band gap semiconductor material 4H-SiC are designed in this work. Detectors D1 and D2 used nickel (Ni) and high melting point tungsten (W) as the front Schottky contact electrode metals, respectively, while detector D3 added a silicon dioxide (SiO 2 ) interlayer at the W metal-semiconductor interface. Current-voltage measurements show that the detectors D1, D2 and D3 have typical Schottky rectification characteristics. The transient current pulse response of the detectors is affected by different applied bias voltages and incident particle energies. At room temperature, the detector D3 with SiO 2 interlayer shows the highest neutron detection efficiency of 6.57%. It also demonstrates that the SiO 2 interlayer can reduce the leakage current due to high surface states and surface damage generated during process fabrication. The neutron irradiation of the detectors at high temperature (150 °C) is also studied, and very small differences in the energy spectra of the detectors are observed compared to those in a room-temperature environment, demonstrating that the 4H-SiC based Schottky-type microstructure neutron detectors have the capability of detecting neutrons at high temperatures as well.
30 July 2025 in IEEE Transactions on Device and Materials Reliability
This paper presents the 2-D numerical simulation results of the heavy-ion-induced single-event leakage current (SELC) degradation and single-event burnout (SEB) in the silicon-carbide (SiC) avalanche photodiode (APD). The employed simulation physics models and material parameters are validated by the reverse I-V characteristics and spectral response characteristics in experiments. The region most sensitive to heavy ion is identified. Then, the SEB failure behavior of SiC APD is investigated. Based on the analysis of ion-induced SELC degradation or SEB failure, three hardening methods–modifying the mesa etch depth, introducing Low Carrier Lifetime Control (LCLC) region, and inserting buffer layer-are investigated. As a result, the effects of three hardening methods on the electrical properties and SEB performance for SiC APD are compared.
1 March 2026 in AIP Advances
This study attempted to apply a helicon plasma source to a compact Deuterium–Deuterium (D–D) neutron generator, ultimately achieving a maximum neutron yield of up to 1.27 × 109 n/s with stable operation for over 1 h. By investigating deuterium plasma characteristics with a Nagoya-III antenna in a permanent magnet helicon device, we established a correlation between its atomic spectral lines and plasma density. The results show that the transition power for deuterium plasma from the inductively coupled mode (H mode) to the magnetically enhanced inductively coupled mode (ME-H mode) is ∼400 W. However, constrained by the maximum power limit of the matching network (1000 W), we were unable to achieve wave coupled mode (W-mode) operation. Then, based on the discharge characteristics of the helicon deuterium plasma, a compact D–D neutron generator utilizing helicon deuterium plasma was constructed, and experiments on deuterium ion beam extraction were carried out. It was observed that when the discharge mode transitions from H-mode to ME-H-mode, the extracted beam intensity increases several-fold. Furthermore, there exists an optimum gas feed rate that maximizes the extracted beam intensity, and compared to inductively coupled ion sources, the system demonstrates higher gas-utilization efficiency. Although the power limitation of the matching network prevented the helicon discharge from reaching W-mode, the results of this study confirm the distinct advantages of helicon plasma sources for application in compact D–D neutron generators, thereby laying the groundwork for the further adoption of helicon ion sources in this field.