25 December 2024 in IEEE Electron Device Letters
Compact, accurate, and durable thermal neutron detectors utilizing ultra-wide bandgap semiconductors, such as gallium oxide (Ga2O $_{{3}}\text {)}$ and diamond, hold great promise for the safe and long-term near-core monitoring of nuclear reactors in harsh environments. However, achieving low device leakage and efficient neutron detection remains a significant challenge. In this work, we demonstrate the first thermal neutron detector based on a large-area (9 mm $^{{2}}\text {)}$ p-NiO/ $\beta $ -Ga2O3 heterojunction diode. The device benefits from a low interfacial trap density, as demonstrated by the slight capacitance-frequency dispersion and low 1/f noise-equivalent power, resulting in an ultralow leakage current of $10^{-{8}}$ A (at −200 V). Consequently, it exhibits efficient charge collection efficiency for alpha particles (5.486 MeV) with an energy resolution of 10%. By integrating 10B film for neutron conversion, we achieved an intrinsic neutron detection efficiency of 0.82%, which approaches the predicted value from the Monte Carlo method, corresponding to 2.22% for thermal neutrons. These findings underscore the potential of $\beta $ -Ga2O3 for applications in advanced radiation monitoring.
1 July 2024 in IEEE Transactions on Instrumentation and Measurement
In this paper, a trench Schottky barrier diode structure based on a wide band-gap, high temperature and irradiation resistant 4H-SiC material is innovatively proposed, and the neutron conversion material 6 LiF is filled into the trench array to make a neutron detector. The detector increases both the amount of 6 LiF filling and the total contact area between 6 LiF and the semiconductor material 4H-SiC by etching out the trenches. The neutron response experimental study revealed that the count rate of the detector is as high as 580 cps, corresponding to a detection efficiency of 6.57%, which breaks through the limitation that the detection efficiency of thin-film coated type detectors is less than 5%, which is one of the main contributions of the detector. The utilization of refractory metal tungsten (W) as the frontal Schottky contact electrode enables the detector to maintain a count rate of approximately 100 cps at 180 °C, which indicates that there exists a possibility that the detector can work in high temperature environments, and also provides experimental basis for the development of high temperature resistant neutron detectors.
1 October 2025 in IEEE Transactions on Nuclear Science
In specialized fields such as fusion energy, aerospace, and nuclear power, radiation detectors are often required to operate reliably at high temperatures. Wide-bandgap semiconductors offer a promising pathway for developing more compact, sensitive, and high-precision detection systems. However, conventional silicon-based preamplifiers suffer from performance degradation and increased noise under elevated temperatures, limiting the effectiveness of these advanced detectors. Silicon carbide (SiC) devices present a compelling alternative for realizing high-temperature, low-noise preamplifiers. This study investigates the electrical output characteristics and noise performance of SiC-based junction field-effect transistors (JFETs) at high temperatures. Due to the intrinsic properties of SiC—such as its wide bandgap and incomplete ionization—simply substituting silicon with SiC in an identical structure does not achieve optimal results. Building on prior research, this work systematically explores how JFET structural design influences device performance by comparing the electrical characteristics and output noise of devices with varying channel parameters across a range of temperatures. The results highlight the effects of channel doping concentration and channel height on transconductance and equivalent output noise under high-temperature conditions, offering valuable design guidance for low-noise, high-temperature SiC-JFETs. Furthermore, this paper presents the experimental fabrication and performance evaluation of SiC-JFETs specifically designed for front-end circuits in nuclear electronics. Key electrical parameters are analyzed as functions of temperature. These findings provide a foundation for advancing SiC-JFET-based front-end electronics in nuclear detection systems.
18 November 2024 in IEEE Transactions on Instrumentation and Measurement
In order to meet the demand for neutron detection in extreme environments with high temperature, high pressure and strong radiation, different Schottky-type microstructure neutron detectors based on the wide band gap semiconductor material 4H-SiC are designed in this work. Detectors D1 and D2 used nickel (Ni) and high melting point tungsten (W) as the front Schottky contact electrode metals, respectively, while detector D3 added a silicon dioxide (SiO 2 ) interlayer at the W metal-semiconductor interface. Current-voltage measurements show that the detectors D1, D2 and D3 have typical Schottky rectification characteristics. The transient current pulse response of the detectors is affected by different applied bias voltages and incident particle energies. At room temperature, the detector D3 with SiO 2 interlayer shows the highest neutron detection efficiency of 6.57%. It also demonstrates that the SiO 2 interlayer can reduce the leakage current due to high surface states and surface damage generated during process fabrication. The neutron irradiation of the detectors at high temperature (150 °C) is also studied, and very small differences in the energy spectra of the detectors are observed compared to those in a room-temperature environment, demonstrating that the 4H-SiC based Schottky-type microstructure neutron detectors have the capability of detecting neutrons at high temperatures as well.
13 November 2025 in IEEE Transactions on Nuclear Science
Silicon carbide (SiC) neutron detectors are promising for various applications due to their high-temperature tolerance and radiation resistance. However, despite their ability to function in extreme environments, SiC detectors experience performance drift at elevated temperatures. This arises not only from changes in the semiconductor’s physical properties but also from shifts in its electrical characteristics, influenced by material defects and fabrication processes. This study employs Monte Carlo and semiconductor device simulations to analyze the temperature-dependent behavior of SiC neutron detectors under real-world operating conditions. First, the variation of output current with temperature is examined using an ideal detector model. A method for deriving the energy spectrum from current pulses and particle distribution is introduced, with its temperature dependence assessed. Next, the impact of temperature-induced leakage current on energy spectrum distortion in practical devices is investigated, offering a predictive approach for device output characteristics under varying thermal conditions. Simulation results indicate that although pulse current decreases significantly with rising temperature, charge collection remains relatively stable. A slight drift in the detector’s energy spectrum is observed, primarily due to variations in ionization energy and carrier mobility. When the leakage current effects in real detectors are considered, the energy spectrum shape degrades, leading to worsening energy resolution and a substantial decline in detection efficiency.
1 September 2026 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment