Elfar Adalsteinsson

Elfar Adalsteinsson

Auto-generated profile, based on publicly available information

Elfar Adalsteinsson

Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2014 in NeuroImage
Verified
Journal Article
Open access
AFAudrey P. Fan
Audrey P. Fan
KEKarleyton C. Evans
Karleyton C. Evans
JSJeffrey N. Stout
Jeffrey N. Stout
BRBruce R. Rosen
Bruce R. Rosen
EAElfar Adalsteinsson
Elfar Adalsteinsson
There is an unmet medical need for noninvasive imaging of regional brain oxygenation to manage stroke, tumor, and neurodegenerative diseases. Oxygenation imaging from magnetic susceptibility in MRI is a promising new technique to measure local venous oxygen extraction fraction (OEF) along the cerebral venous vasculature. However, this approach has not been tested in vivo at different levels of oxygenation. The primary goal of this study was to test whether susceptibility imaging of oxygenation can detect OEF changes induced by hypercapnia, via CO2 inhalation, within selected a priori brain regions. Ten healthy subjects were scanned at 3 T with a 32-channel head coil. The end-tidal CO2 (ETCO2) was monitored continuously and inspired gases were adjusted to achieve steady-state conditions of eucapnia (41 ± 3 mm Hg) and hypercapnia (50 ± 4 mm Hg). Gradient echo phase images and pseudo-continuous arterial spin labeling (pcASL) images were acquired to measure regional OEF and CBF respectively during eucapnia and hypercapnia. By assuming constant cerebral oxygen consumption throughout both gas states, regional CBF values were computed to predict the local change in OEF in each brain region. Hypercapnia induced a relative decrease in OEF of − 42.3% in the straight sinus, − 39.9% in the internal cerebral veins, and approximately − 50% in pial vessels draining each of the occipital, parietal, and frontal cortical areas. Across volunteers, regional changes in OEF correlated with changes in ETCO2. The reductions in regional OEF (via phase images) were significantly correlated (P < 0.05) with predicted reductions in OEF derived from CBF data (via pcASL images). These findings suggest that susceptibility imaging is a promising technique for OEF measurements, and may serve as a clinical biomarker for brain conditions with aberrant regional oxygenation.

10 October 2019
Verified
Book Chapter
Closed access
PDF file
JXJunshen Xu
Junshen Xu
MZMolin Zhang
Molin Zhang
ETEsra Abaci Turk
Esra Abaci Turk
LZLarry Zhang
Larry Zhang
PGP. Ellen Grant
P. Ellen Grant
EAElfar Adalsteinsson
Elfar Adalsteinsson

10 December 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
BGBorjan Gagoski
Borjan Gagoski
JXJunshen Xu
Junshen Xu
PWPaul Wighton
Paul Wighton
MTM. Dylan Tisdall
M. Dylan Tisdall
RFRobert Frost
Robert Frost
PGPatricia Ellen Grant
Patricia Ellen Grant

1 October 2016 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
ICItthi Chatnuntawech
Itthi Chatnuntawech
AMAdrian Martin
Adrian Martin
BBBerkin Bilgic
Berkin Bilgic
KSKawin Setsompop
Kawin Setsompop
EAElfar Adalsteinsson
Elfar Adalsteinsson
ESEmanuele Schiavi
Emanuele Schiavi

6 November 2019 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
DBD.S. Bolar
D.S. Bolar
BGB. Gagoski
B. Gagoski
DOD.B. Orbach
D.B. Orbach
ESE. Smith
E. Smith
EAE. Adalsteinsson
E. Adalsteinsson
RRR.L. Robertson
R.L. Robertson
BACKGROUND AND PURPOSE: Imaging CBF is important for managing pediatric moyamoya. Traditional arterial spin-labeling MR imaging detects delayed transit thorough diseased arteries but is inaccurate for measuring perfusion because of these delays. Velocity-selective arterial spin-labeling is insensitive to transit delay and well-suited for imaging Moyamoya perfusion. This study assesses the accuracy of a combined velocity-selective arterial spin-labeling and traditional pulsed arterial spin-labeling CBF approach in pediatric moyamoya, with comparison to blood flow patterns on conventional angiography. MATERIALS AND METHODS: Twenty-two neurologically stable pediatric patients with moyamoya and 5 asymptomatic siblings without frank moyamoya were imaged with velocity-selective arterial spin-labeling, pulsed arterial spin-labeling, and DSA (patients). Qualitative comparison was performed, followed by a systematic comparison using ASPECTS-based scoring. Quantitative pulsed arterial spin-labeling CBF and velocity-selective arterial spin-labeling CBF for the middle cerebral artery, anterior cerebral artery, and posterior cerebral artery territories were also compared. RESULTS: Qualitatively, velocity-selective arterial spin-labeling perfusion maps reflect the DSA parenchymal phase, regardless of postinjection timing. Conversely, pulsed arterial spin-labeling maps reflect the DSA appearance at postinjection times closer to the arterial spin-labeling postlabeling delay, regardless of vascular phase. ASPECTS comparison showed excellent agreement (88%, κ = 0.77, P < .001) between arterial spin-labeling and DSA, suggesting velocity-selective arterial spin-labeling and pulsed arterial spin-labeling capture key perfusion and transit delay information, respectively. CBF coefficient of variation, a marker of perfusion variability, was similar for velocity-selective arterial spin-labeling in patient regions of delayed-but-preserved perfusion compared to healthy asymptomatic sibling regions (coefficient of variation = 0.30 versus 0.26, respectively, Δcoefficient of variation = 0.04), but it was significantly different for pulsed arterial spin-labeling (coefficient of variation = 0.64 versus 0.34, Δcoefficient of variation = 0.30, P < .001). CONCLUSIONS: Velocity-selective arterial spin-labeling offers a powerful approach to image perfusion in pediatric moyamoya due to transit delay insensitivity. Coupled with pulsed arterial spin-labeling for transit delay information, a volumetric MR imaging approach capturing key DSA information is introduced.

1 March 2010 in Journal of Magnetism and Magnetic Materials
Verified
Journal Article
Open access
PCPádraig Cantillon-Murphy
Pádraig Cantillon-Murphy
LWL.L. Wald
L.L. Wald
EAE. Adalsteinsson
E. Adalsteinsson
MZMarkus Zahn
Markus Zahn
In the presence of alternating-sinusoidal or rotating magnetic fields, magnetic nanoparticles will act to realign their magnetic moment with the applied magnetic field. The realignment is characterized by the nanoparticle’s time constant, τ. As the magnetic field frequency is increased, the nanoparticle’s magnetic moment lags the applied magnetic field at a constant angle for a given frequency, Ω, in rad/s. Associated with this misalignment is a power dissipation that increases the bulk magnetic fluid’s temperature which has been utilized as a method of magnetic nanoparticle hyperthermia, particularly suited for cancer in low-perfusion tissue (e.g., breast) where temperature increases of between 4°C and 7°C above the ambient in vivo temperature cause tumor hyperthermia. This work examines the rise in the magnetic fluid’s temperature in the MRI environment which is characterized by a large DC field, B0. Theoretical analysis and simulation is used to predict the effect of both alternating-sinusoidal and rotating magnetic fields transverse to B0. Results are presented for the expected temperature increase in small tumors (~1 cm radius) over an appropriate range of magnetic fluid concentrations (0.002 to 0.01 solid volume fraction) and nanoparticle radii (1 to 10 nm). The results indicate that significant heating can take place, even in low-field MRI systems where magnetic fluid saturation is not significant, with careful selection of the rotating or sinusoidal field parameters (field frequency and amplitude). The work indicates that it may be feasible to combine low-field MRI with a magnetic hyperthermia system using superparamagnetic iron oxide nanoparticles.