Passive solid state dosimeters, such as thermoluminescence dosimeters, provide integrated measurement of the total dose and are widely used in environmental monitoring programs. The objective of this paper is to provide a comprehensive review on the use of thermoluminescent dosimetry methods for monitoring radiation dose in the environment. The article presents the part of the research results of the project PREPAREDNESS (EMPIR 2016 call for Metrology for Environment joint research project) with a particular objective to harmonize procedures used by dosimetry services, relevant authorities and Institutes across the Europe. To achieve this, different monitoring routines that are based on passive environ mental dosimetry methods are investigated. Differences in performing specific steps such as preheating, reading, annealing, minimizing fading, and others, are analyzed. The investigation was performed by means of qualitative literature review that showed the lack of information about specific steps. The conclusion of this work is that thermoluminescent dosimetry measurement system has to be type-tested even though the testing procedure is complicated. In addition to this, control dosimeters should be introduced, International Organization for Standardization protocols should be followed during calibration, and finally, parameters influencing the measurement uncertainty have to be identified and well understood in order to pro duce ac cu rate dose measurement results.
Medical personnel performing interventional procedures in cardiology and radiology is considered to be a professional group exposed to high doses of ionizing radiation. Reduction of the eye lens dose limit made its assessment in the interventional procedures one of the most challenging topics. The objective of this work is to assess eye lens doses based on the whole-body doses using methods of computational dosimetry. Assessment included different C-arm orientations (PA, LAO and RAO), tube voltages (80 –110 kV) and efficiency of different combinations of protective equipment used in interventional procedures. Center position at the height of the thyroid gives best estimate of eye lens dose, with spreads of 11% (13%), 13% (17%) and 14% (13%) for the left (right) eye lens. The conversion factors of 1.03 (0.83), 1.28 (1.06) and 1.36 (1.06) to convert whole body to eye lens dose were derived for positions of first operator, nurse and radiographer, respectively. The eye lens dose reduction factors for different combinations of applied protective equipment are 178, 5 and 6, respectively.
11 January 2019 in Journal of Radiological Protection
Following the proposal of the ICRP for the reduction of the dose limit for the lens of the eye, which has been adopted by the International Atomic Energy Agency and the European Council, concerns have been raised about the implementation of proper dose monitoring methods as defined in national regulations, and about the harmonisation between European countries. The European Radiation Dosimetry Group organised a survey at the end of 2017, through a web questionnaire, regarding national dose monitoring regulations. The questions were related to: double dosimetry, algorithms for the estimation of the effective dose, methodology for the determination of the equivalent dose to the lens of the eye and structure of the national dose registry. The results showed that more than 50% of the countries that responded to the survey have legal requirements about the number and the position of dosemeters used for estimation of the effective dose when radiation protection garments are used. However, in only five out of 26 countries are there nationally approved algorithms for the estimation of the effective dose. In 14 out of 26 countries there is a legal requirement to estimate the dose to the lens of the eye. All of the responding countries use some kind of national database for storing individual monitoring data but in only 12 out of 26 countries are the estimated effective dose values stored. The personal dose equivalent at depth 3 mm is stored in the registry of only seven out of 26 countries. From the survey, performed just before the implementation of the European Basic Safety Standards Directive, it is concluded that national occupational exposure frameworks require intensive and immediate work under the coordination of the competent authorities to bring them into line with the latest basic safety standards and achieve harmonisation between European countries.
This study aimed to investigate the level of exposure of eye lenses in orthopedic surgeons performing routine clinical work and to determine future monitoring practice, as Serbian radiation protection law still employs higher limits. The dose was measured monthly in terms of H (0.03) with three different dosimeters placed on a 3-D-printed headband, worn on a forehead by three orthopedic surgeons, during all procedures involving fluoroscopy. The mean dose for the left and right eye was 271 ? 109 ?Sv and 269 ? 101 ?Sv, respectively, with no significant difference (p-value 0.977) between the left and right eye observed. Considering the highest recorded monthly value, the annual dose is expected to be 4.85 mSv without protective items, well below the new ICRP limit of 20 mSv. There was no observed correlation between eye lens dose and both fluoroscopy time and exposure parameters. Considering the cumulative impact of dose and the evidence pointing to an elevated incidence of lenticular opacities for cumulative doses exceeding 10 mSv, it is advisable to institute ongoing monitoring, especially when new surgeons incorporate image-guided procedures or when novel techniques are introduced into surgical practice.
1 January 2018 in Nuclear Technology and Radiation Protection
Medical staff performing interventional procedures in cardiology and radiology is considered to be a professional group exposed to high doses of ionizing radiation. With new epidemiological evidences and recently reduced eye lens dose limit, dose assessment to the lens of the eye, in the interventional cardiology, has become one of the most challenging research topics. This paper presents results of the eye lens dose assessment in interventional cardiology obtained by means of the computational dosimetry. Since placing and wearing the dedicated eye lens dosimeter is encumbering for the staff, Monte Carlo simulation provides an accurate and efficient method for obtaining an indication of doses to the eye lenses. Eye lens doses were estimated for three typical beam projections (PA, LAO, and RAO) and tube voltages ranging from 80 kV to 110 kV, with different protective equipment setups, for the first operator position. Simulations were carried out using MCNPX code. Results revealed that a whole body dosimeter worn at the thyroid center position gives the best estimate of the eye lens dose with a spread from 11 % to 18 % for the left eye. Corresponding average conversion coefficient from whole body to the eye lens dose is estimated to be 0.18.