9 December 2013 in Journal of Separation Science
2 May 2025 in Science Advances
Microwave measurement is crucial in various fields, such as communication, radar, and cognitive radio, now poised for a revolution with the advent of photonic-assisted techniques that promise unprecedented performance. However, existing methods often disrupt the amplitude integrity of unknown signals and rely on time-consuming frequency sweeping to achieve multifrequency detection, which markedly restricts their instantaneous bandwidth, response speed, and accuracy. Here, we present a groundbreaking approach leveraging digital optical frequency comb–enabled stimulated Brillouin scattering to achieve instantaneous microwave frequency and amplitude detection, attaining a record-breaking 50.8-gigahertz bandwidth, a 1.1-megahertz accuracy, and a 500-nanosecond temporal resolution, which is three orders of magnitude improvement over that obtained with frequency sweeping schemes. In addition to conventional frequency detection, the proposed technique enables simultaneous multifrequency microwave amplitude measurement and achieves a substantial performance enhancement in the figure of merit of more than 10-fold, which paves the way for dynamic microwave signal detection and analysis.
26 March 2021 in Journal of Lightwave Technology
Linear optical sampling (LOS) is a powerful technique to circumvent the electronic bottleneck arising in optical modulation analyzer (OMA). To extend the range of operation wavelength for the LOS-based OMA, the fiber optical frequency comb (FOFC) is proposed to replace the mode-locked fiber laser (NMFL) as an optical sampling source. However, this procedure reduces the signal-to-noise (SNR), due to the constraints of the unideal response of balanced photodetector (BPD) and the limited power per FOFC tone. Here, we investigate the biased balance detection (BBD) scheme to overcome such a issue. Our simulation results show that, the characterization performance of the FOFC-based LOS with the help of the BBD scheme is almost the same as that of the NMFL-based LOS, when the PDM-QPSK/16QAM/64QAM signals are set as the signal under test (SUT). Meanwhile, we find that the dynamic range of SUT input power is determined by the BPD imbalance and the FOFC power. By increasing either the average power of the FOFC from 4 to 10 mW or the imbalance of the BPD from 1.03 to 1.04, we can enhance the dynamic range of SUT input power by 8.8 mW and 6.6 mW, respectively. Finally, we develop the equipment and experimentally verify the BBD scheme by a precise characterization of 32 GBaud PDM-QPSK signal.
1 January 2026 in Light: Science & Applications
Distributed fiber-optic sensing has become an indispensable tool for large-scale structural and environmental monitoring, where spectral interrogation of backscattering light enables high-precision quantitative measurement of external perturbations. Conventional spectral analysis methods, typically based on frequency-domain serial interrogation or time-to-frequency mapping, face inherent trade-offs between measurement speed, dynamic strain measurement range, and system complexity. Here, we present a distributed frequency comb enabled spectrum-correlation reflectometry as a universal spectral analysis framework that leverages optical frequency comb for parallel multi-frequency interrogation, which is experimentally demonstrated in a phase-sensitive optical time-domain reflectometry (φ-OTDR) system. This method eliminates the need for large frequency scans, achieving more than tenfold improvement in measurement speed over the state-of-the-art spectral analysis methods. Compared to existing phase-demodulated φ-OTDR systems, this method enables vibration amplitude monitoring with a dynamic strain measurement range expanded by more than an order of magnitude, while intrinsically circumventing phase unwrapping issues and interference fading. This work establishes a new paradigm for distributed spectral analysis, providing a flexible and robust platform for a wide range of sensing technologies, including Rayleigh and Brillouin-based schemes, which may have significant impact for geophysics, seismology, civil engineering, and other fields.
14 October 2024 in IEEE Sensors Journal
We propose and demonstrate a novel dynamic Brillouin optical time domain analysis (BOTDA) by utilizing frequency-agility double-sideband digital optical frequency comb (DOFC) probes. For the first time, simultaneous interrogation of the complex Brillouin gain, loss and corresponding phase spectra is realized without frequency sweeping process. An acoustic-optical modulator is employed to aid in the simultaneous acquisition of full-field Brillouin spectra without sideband selective optical filters, yielding a fixed frequency offset over the spectral range via direct detection. Through the joint analysis of additional spectra, the measurement accuracy can be significantly improved compared to the traditional single-sideband-based schemes. In addition, frequency-agility DOFC probes are used to improve the spatial resolution while maintaining an acceptable frequency resolution. Eventually, the proposed BOTDA achieves a 4-m spatial resolution and less than 1.53-MHz frequency uncertainty over 10-km fiber with 400-MHz dynamic measurement range for the full-field Brillouin spectra. For proof of concept, dynamic vibration measurement is demonstrated with 40 Hz sampling rate. The proposed scheme with full-field Brillouin spectra measurement provides high accuracy enhancement, showcasing a promising application for distributed dynamic sensing.
18 August 2022 in Journal of Lightwave Technology
Transmitter dispersion eye closure quaternary (TDECQ) is one of the most important parameters that can systematically evaluate the signal quality of four-level pulse amplitude modulation format (PAM-4) transmitters. We experimentally demonstrate the acceleration of TDECQ assessment by deep transfer learning (DTL) technique. With the help of amplitude histograms (AHs) generated by the received PAM-4 signal, we are able to characterize the TDECQ value directly by the deep neural network (DNN). To further reduce both the computation time and the experimental data used for the training, simulation data can be used to provide the suitable source domain for the DTL implementation. The experimental results of 25 Gbaud PAM-4 signals indicate that, the mean absolute error of TDECQ assessment is below 0.18 dB over a TDECQ range from 1.9 to 3.6 dB. Meanwhile, 33.3% amount of the used experimental data and 40% epochs can be simultaneously reduced during the training process, due to the use of DTL.