Mohd Faisal

Mohd Faisal

Auto-generated profile, based on publicly available information

Mohd Faisal

Advanced Materials and Nano‐Research Centre (AMNRC) Najran University Najran Saudi Arabia

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
MFMohd Faisal
Mohd Faisal
Md. Mahmud AlamMd. Mahmud Alam
Md. Mahmud Alam
JAJahir Ahmed
Jahir Ahmed
Abdullah M. AsiriAbdullah M. Asiri
Abdullah M. Asiri
MJMohammed Jalalah
Mohammed Jalalah
Farid A. HarrazFarid A. Harraz
Farid A. Harraz
In this study, a selective 4-nitrophenol (4-NP) sensor was developed onto a glassy carbon electrode (GCE) as an electron-sensing substrate, which decorated with sol–gel, prepared Pt nanoparticles- (NPs) embedded polypyrole-carbon black (PPy-CB)/ZnO nanocomposites (NCs) using differential pulse voltammetry. Characterizations of the NCs were performed using Field Emission Scanning Electron Microscopy (FESEM), Energy-Dispersive Spectroscopy (EDS), X-ray Photoelectron Spectroscopy (XPS), Ultraviolet–visible Spectroscopy (UV–vis), Fourier Transform Infrared Spectroscopy (FTIR), High Resolution Transmission Electron Microscopy (HRTEM), and X-ray Diffraction Analysis (XRD). The GCE modified by conducting coating binders [poly(3,4-ethylenedioxythiophene) polystyrene sulfonate; PEDOT:PSS] based on Pt NPs/PPy-CB/ZnO NCs functioned as the working electrode and showed selectivity toward 4-NP in a phosphate buffer medium at pH 7.0. Our analysis of 4-NP showed the linearity from 1.5 to 40.5 µM, which was identified as the linear detection range (LDR). A current versus concentration plot was formed and showed a regression co-efficient R2 of 0.9917, which can be expressed by ip(µA) = 0.2493C(µM) + 15.694. The 4-NP sensor sensitivity was calculated using the slope of the LDR, considering the surface area of the GCE (0.0316 cm2). The sensitivity was calculated as 7.8892 µA µM−1 cm−2. The LOD (limit of detection) of the 4-NP was calculated as 1.25 ± 0.06 µM, which was calculated from 3xSD/σ (SD: Standard deviation of blank response; σ: Slope of the calibration curve). Limit of quantification (LOQ) is also calculated as 3.79 µM from LOQ = 10xLOD/3.3. Sensor parameters such as reproducibility, response time, and analyzing stability were outstanding. Therefore, this novel approach can be broadly used to safely fabricate selective 4-NP sensors based on nanoparticle-decorated nanocomposite materials in environmental measurement.

29 August 2022 in Colloids and Surfaces A: Physicochemical and Engineering Aspects
Verified
Journal Article
Closed access
Farid A. HarrazFarid A. Harraz
Farid A. Harraz
ARA. Rashed
A. Rashed
MFM. Faisal
M. Faisal
MAMabkhoot Alsaiari
Mabkhoot Alsaiari
SASaeed Alsareii
Saeed Alsareii

17 November 2022 in Membranes
Verified
Journal Article
Open access
PDF file
MJMohammed Jalalah
Mohammed Jalalah
AAAdnan Ahmad
Adnan Ahmad
ASAsad Saleem
Asad Saleem
MQMuhammad Bilal Qadir
Muhammad Bilal Qadir
ZKZubair Khaliq
Zubair Khaliq
Farid A. HarrazFarid A. Harraz
Farid A. Harraz
Textile-supported nanocomposite as a scaffold has been extensively used in the medical field, mainly to give support to weak or harmed tissues. However, there are some challenges in fabricating the nanofiber/textile composite, i.e., suitable porous structure with defined pore size, less skin contact area, biocompatibility, and availability of degradable materials. Herein, polyamide-6 (PA) nanofibers were synthesized using needleless electrospinning with the toothed wheel as a spinneret. The electrospinning process was optimized using different process and solution parameters. In the next phase, optimized PA nanofiber membranes of optimum fiber diameter with uniform distribution and thickness were used in making nanofiber membrane–textile composite. Different textile fabrics (woven, non-woven, knitted) were developed. The optimized nanofiber membranes were combined with non-woven, woven, and knitted fabrics to make fabric-supported nanocomposite. The nanofiber/fabric composites were compared with available market woven and knitted meshes for mechanical properties, morphology, structure, and chemical interaction analysis. It was found that the tear strength of the nanofiber/woven composite was three times higher than market woven mesh, and the nanofiber/knitted composite was 2.5 times higher than market knitted mesh. The developed composite structures with woven and knitted fabric exhibited improved bursting strength (613.1 and 751.1 Kpa), tensile strength (195.76 and 227.85 N), and puncture resistance (68.76 and 57.47 N), respectively, than market available meshes. All these properties showed that PA nanofibers/textile structures could be utilized as a composite with multifunctional properties.

1 January 2019 in Brazilian Archives of Biology and Technology
Verified
Journal Article
Open access
PDF file
EMElsayed Masoud
Elsayed Masoud
AMAli Al-Hajry Mohammad
Ali Al-Hajry Mohammad
Farid A. HarrazFarid A. Harraz
Farid A. Harraz
MAMohd Faisal Ahsan
Mohd Faisal Ahsan
Keywords: Silver nanoparticles; Biosynthesis; Plant extracts; Tetracycline; S. aureus; K. pneumoniae

8 March 2023 in Polymers
Verified
Journal Article
Open access
PDF file
Ali AfzalAli Afzal
Ali Afzal
MJMohammed Jalalah
Mohammed Jalalah
ANAbid Noor
Abid Noor
ZKZubair Khaliq
Zubair Khaliq
MQMuhammad Bilal Qadir
Muhammad Bilal Qadir
Farid A. HarrazFarid A. Harraz
Farid A. Harraz
Nowadays, synthetic polymers are used in medical applications due to their special biodegradable, biocompatible, hydrophilic, and non-toxic properties. The materials, which can be used for wound dressing fabrication with controlled drug release profile, are the need of the time. The main aim of this study was to develop and characterize polyvinyl alcohol/polycaprolactone (PVA/PCL) fibres containing a model drug. A dope solution comprising PVA/PCL with the drug was extruded into a coagulation bath and became solidified. The developed PVA/PCL fibres were then rinsed and dried. These fibres were tested for Fourier transform infrared spectroscopy, linear density, topographic analysis, tensile properties, liquid absorption, swelling behaviour, degradation, antimicrobial activity, and drug release profile for improved and better healing of the wound. From the results, it was concluded that PVA/PCL fibres containing a model drug can be produced by using the wet spinning technique and have respectable tensile properties; adequate liquid absorption, swelling %, and degradation %; and good antimicrobial activity with the controlled drug release profile of the model drug for wound dressing applications.

2 September 2023 in Journal of the Taiwan Institute of Chemical Engineers
Verified
Journal Article
Closed access
ARA. Rashed
A. Rashed
NNN.i. Nayem
N.i. Nayem
MRM. Hafizur Rahman
M. Hafizur Rahman
MFM. Faisal
M. Faisal
Jari Saeed AlgethamiJari Saeed Algethami
Jari Saeed Algethami
Farid A. HarrazFarid A. Harraz
Farid A. Harraz