Ruslan Likhnyovskyi

Ruslan Likhnyovskyi

Auto-generated profile, based on publicly available information

Ruslan Likhnyovskyi

Institute of Scientific Research on Civil Protection of the National University of Civil Protection of Ukraine

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2001 in Adsorption Science & Technology
Verified
Journal Article
Open access
LPL. Patrylak
L. Patrylak
RLR. Likhnyovskyi
R. Likhnyovskyi
VVV. Vypyraylenko
V. Vypyraylenko
RLR. Leboda
R. Leboda
JSJ. Skubiszewska-Zięba
J. Skubiszewska-Zięba
KPK. Patrylak
K. Patrylak
A series of samples of zeolite-containing microspheres (ZCMS) and fluid catalytic cracking (FCC) catalysts based on Prosyana (Ukraine) kaolin were synthesized in situ. Their adsorption and chemisorption characteristics were recorded using a nitrogen low-temperature adsorption/desorption method and temperature programmed desorption (TPD) of ammonia, respectively. It was shown that changes in the synthesis conditions had a considerable impact on the micro- and meso-porosity of the samples. A low-temperature band dominated the ammonia TPD spectra of the ZCMS samples, reflecting the retention of ammonia by the sodium cations of the zeolite acting as weak Lewis acid sites. ZCMS was found to display an appreciable activity in cumene cracking at 723 K. It was shown that during the conversion of ZCMS to FCC catalysts through the decationization and ultra-stabilization of the zeolite phase, the latter is appreciably destroyed giving rise to a considerable increase in the mesoporosity of the samples without any change in the average diameters of such mesopores. It was concluded that the catalyst stability is characterized by pores of an intermediate (20–30 Å) diameter, thereby demonstrating the strength of the linkage between the zeolite and matrix phases. The zeolite phase content and adsorption characteristics of catalysts prepared on the basis of Prosyana kaolin meet the demands of modern FCC catalysts.

30 June 2023 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
YTYuriy Tsapko
Yuriy Tsapko
RLRuslan Likhnyovskyi
Ruslan Likhnyovskyi
АTАleksii Tsapko
Аleksii Tsapko
VKVitalii Kovalenko
Vitalii Kovalenko
OSOksana Slutska
Oksana Slutska
YGYuriy Gulyk
Yuriy Gulyk
An issue related to the use of foaming agents to extinguish fires involving flammable liquids is to ensure the efficiency of vapor insulation of flammable liquid and the foam stability during operation. Therefore, the object of research was a change in the insulating properties of the foaming agent film when interacting with a polar combustible substance. It has been proven that the presence of foaming agent on a flammable liquid leads to the formation of an insulating film on the surface resistant to the combustion temperature of the liquid, due to which re-ignition shifts towards longer time. A film of foaming agent was formed on the surface of the flammable liquid by leaking from the screen, which led to the insulation of the surface. The measured contact area of the foaming film with the electrode was more than 6.2·10-3 m2, which indicates the formation of a barrier for temperature, which collapses over time. According to experimental data on changes in electrical resistance, the critical contact area of the foaming film with the electrode was calculated, at which the film is destroyed. Based on the derived dependences, the change in the process of mass transfer of the foaming film to a flammable liquid was calculated, equal to about 800 s. The maximum possible mass transfer of the foaming agent into the flammable liquid and the reduction of insulation capacity were evaluated. The peculiarities of foam supply to the surface of alcohol through the screen are that the quenching time was about 156 s while the critical intensity of the supply of the working solution of the foaming agent was 0.054 dm3/(m2·s). And the time interval before re-ignition was about 470 s, which is enough to cool the fire site. Thus, there is reason to assert the possibility of targeted control over the processes of extinguishing polar flammable liquids with a foaming agent

30 August 2022 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
YTYuriy Tsapko
Yuriy Tsapko
NBNataliia Buiskykh
Nataliia Buiskykh
RLRuslan Likhnyovskyi
Ruslan Likhnyovskyi
OHOleksandra Horbachova
Oleksandra Horbachova
АTАleksii Tsapko
Аleksii Tsapko
MSMaryna Sukhanevych
Maryna Sukhanevych
The issue related to using dry wood products for building structures is to ensure their stability and durability during operation while it is necessary to take into consideration changes in their properties and structure. Therefore, the object of this study was pine wood struck by drying out. It is proved that in the process of drying, wood porosity decreases, and, accordingly, the tensile strength, depending on the degree of damage by the fungus. Specifically, with the area of damage in the range of 30‒50 %, the strength limit decreases by more than 1.3 times, and if the fungus affects the area within 80÷100 %, the wood becomes softer, more ductile while the strength limit is reduced by 1.1 times. Based on the results of physicochemical studies, discrepancies in the IR spectra were identified, indicating structural changes in the constituent components of wood. There is a decrease or absence of intensities of absorption bands of some functional groups and the appearance or intensification of others. Wood samples, in determining the highest calorific value, show a difference in values, which is explained by structural changes in wood components caused by biological processes. Thermogravimetric analysis data indicate complete burnout of dry pine wood. However, for wood with tree stands not weakened by drying, the coke residue burns out at a higher temperature. Wood with blue pigmentation affected by microorganisms has significant differences in the heating area of 400÷700 °C. The nature of coke burnout allows us to make assumptions about the different qualitative and quantitative composition of the coke residue, which is formed due to structural changes. The practical significance is the fact that the results of determining the properties and structure of dry wood make it possible to establish the operating conditions for articles and building structures

30 December 2022 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
YTYuriy Tsapko
Yuriy Tsapko
RLRuslan Likhnyovskyi
Ruslan Likhnyovskyi
OHOleksandra Horbachova
Oleksandra Horbachova
SMSerhii Mazurchuk
Serhii Mazurchuk
АTАleksii Tsapko
Аleksii Tsapko
MSMaryna Sukhanevych
Maryna Sukhanevych
An issue related to using wood and timber for building structures is to ensure the stability and durability during operation within wide limits. Therefore, the object of research was the inhibition of the process of water absorption of pine and hornbeam wood during a thermal change in its structure. It is proved that in the process of thermal modification of wood, its structure changes, and, accordingly, water absorption. Namely, the maximum increase in mass under the action of water on an untreated sample of wood was more than 40 %, after thermal modification – less than 35 %. The increase in the mass of wood samples thermally modified and treated with a hydrophobic agent was less than 25 %. On the basis of the obtained results of physicochemical studies, discrepancies were found in the IR spectra of wood, both during thermal modification and with additional treatment with a hydrophobic agent, indicating structural changes in the components. In particular, the decrease or absence of the intensities of the absorption bands of some functional groups and the appearance or intensification of others. On the original hornbeam and pine thermogram, thermally modified, and thermally modified with the addition of a hydrophobic coating, thermogravimetric curves are similar to each other and are characterized by a loss of sample mass. This is possible with increasing temperature due to the processes of dehydration, destruction of hemicellulose, lignin, and cellulose with the formation of a non-combustible residue. During heat treatment of cellulose in the region of temperatures of 150÷450 °C, two processes take place in parallel. This is dehydration, accompanied by the destruction of the pyranose cycle and carbonization to form a carbon residue. Also, the process of destruction of glycosidic bonds while maintaining hydroxyl groups, accompanied by regrouping of pyranose cycles.

31 August 2023 in Key Engineering Materials
Verified
Journal Article
Closed access
PDF file
RLRuslan Likhnyovskyi
Ruslan Likhnyovskyi
YTYuriy Tsapko
Yuriy Tsapko
VKVitalii Kovalenko
Vitalii Kovalenko
AOAndrii Onyshchuk
Andrii Onyshchuk
Halons are usually used for fire extinguishing where other types of extinguishing agents cannot be used. Their use does not require disconnection of electrical networks, does not lead to any damage, and after airing the premises, these substances do not leave any residues. Halons are used as flame retardants in concentrations (from 2 to 12% vol.). In the case of their use, a decrease in the oxygen content in the air of the flame center’s due to dilution is not significant, and extinguishing occurs as a result of the slowing down and interruption of chain chemical reactions in the flame. Combustion inhibitors play the role of a "negative catalyst", the mechanism of their action consists in high reactivity to interact with radicals with the formation of inert compounds, thereby interrupting the chain reaction of combustion and slowing down its development. The concentrations of bromotrifluoromethane (halon 1301) and 1,2-dibromotetrafluoroethane (halon 2402) in the mixtures were determined by the gas chromatographic method, and experimental researches for determining the minimum fire-extinguishing concentration established that the halons 1301 and 2402 mixtures show high efficiency in extinguishing flames. Established, that the mixture of halons 1301 and 2402 with the concentration of the latter in the range of 60÷65% exhibits the best minimum fire-extinguishing concentration. At these values, the minimum fire-extinguishing concentration did not exceed 2.0% vol. It was determined that when reducing the concentration of oxygen in the air by halon 1301 from 20.5 to 19% of volume, the concentration of halon 2402 for extinguishing n-heptane decreases by 2.5 times. Inhibition of the n-heptane flame combustion process by such mixtures of halons is associated with the decomposition of halons under the influence of temperature with the absorption of heat and releasing of combustion inhibitors, a change in the direction of decomposition towards the formation of non-combustible gases and the cessation of oxygen access. This indicates possibility of using available gas extinguishing substances - halons - for fire extinguishing.

29 April 2023 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
YTYuriy Tsapko
Yuriy Tsapko
RLRuslan Likhnyovskyi
Ruslan Likhnyovskyi
АTАleksii Tsapko
Аleksii Tsapko
VKVitalii Kovalenko
Vitalii Kovalenko
OSOksana Slutska
Oksana Slutska
MSMaryna Sukhanevych
Maryna Sukhanevych
An issue related to using cable products for building structures is to ensure their stability and durability when operating within wide limits. Therefore, the object of research was a change in the properties of the polymer sheath of the cable during the formation of a swollen coating layer under the influence of high temperature. It is proved that in the process of thermal action on the flame retardant coating, the process of thermal insulation of the cable involves the formation of particulate products on the surface of the sample. Under the action of the burner flame, a temperature was reached on the surface of the sample, which led to a swelling of the coating of more than 16 mm. The measured temperature on the inverse surface of the sample was no more than 160 °C, which indicates the formation of a barrier for temperature. In this regard, a calculation and experimental method for determining thermal conductivity when using a flame retardant as a coating has been developed, which makes it possible to estimate the coefficients of temperature conductivity and thermal conductivity under high-temperature action. According to the experimental data and established dependences, the coefficients of temperature conductivity and thermal conductivity of wood were calculated, which are 214.4·10–6 m2/s and 0.62 W/(m∙K), respectively, due to the formation of a heat-insulating swollen layer. The maximum possible temperature penetration through the thickness of the coating was assessed. A temperature was created on the surface of the sample, which significantly exceeds the ignition temperature of the polymer sheath of the cable, and, on a non-heated surface, does not exceed 160 °C. Thus, there is reason to argue about the possibility of directed adjustment of the fire protection processes of an electrical cable by using coatings capable of forming a protective layer on the surface of the material, which inhibits the rate of heat transfer.