Ke Shi

Ke Shi

Auto-generated profile, based on publicly available information

Ke Shi

School of Instrument Science and Engineering, Southeast University, Nanjing, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YLYe Lu
Ye Lu
HLHuijun Li
Huijun Li
KSKe Shi
Ke Shi
JLJianwei Lai
Jianwei Lai
YLYe Li
Ye Li
ASAiguo Song
Aiguo Song
The tendon–sheath system (TSS) has emerged as a promising solution for force transmission in robot applications, owing to the lightweight, low inertia, and good flexibility. However, the performance of tension control is affected by the configuration-dependent nonlinearities, and achieving precise control of the distal force of TSS in time-varying configurations remains a challenge. To address this issue, this article proposes a comprehensive method combining feedforward and feedback control to enhance the control accuracy of TSS by estimating the bending angle in real time, even when the system configuration is unknown. A bending angle estimation approach based on a friction model is proposed, and an improved friction model is developed to simulate the nonlinear friction more accurately. Furthermore, a double-TSS transmission structure is designed to facilitate the integration of control and configuration feedback in mechanical systems. The experimental results confirm the effectiveness of the proposed method in enhancing force-tracking performance in unknown configurations.

9 April 2025 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
MZMaozeng Zhang
Maozeng Zhang
HLHuijun Li
Huijun Li
KSKe Shi
Ke Shi
ASAiguo Song
Aiguo Song
Joint stiffness control is essential for safe and compliant human–robot interaction in rehabilitation exoskeletons. Variable stiffness actuators (VSAs), with controllable physical stiffness, offers a potential solution. However, existing VSAs generally do not allow both motors to contribute to power output simultaneously, which limits their performance in human–robot interaction. Therefore, the goal of this article is to develop a novel variable stiffness actuator with dual-motor load sharing (DMLS-VSA) and its stiffness and torque control scheme. The innovative DMLS-VSA mechanism features a power transmission mechanism (PTM) and a variable stiffness mechanism (VSM). The PTM enables the DMLS-VSA to have dual-motor load sharing capability, allowing the output power to be determined by both motors. Meanwhile, the VSM utilizes a modified planetary gear mechanism to achieve stiffness variation by regulating the effective lever arm length. In this differential configuration, the motion of both motors changes the output torque and stiffness. Consequently, a novel cascade PI controller, with the position-loop control term acting directly on the deflection angle and stiffness, is used to control the DMLS-VSA, preventing undesired movements during motion. The performance of the DMLS-VSA is verified through experiments on stiffness regulation, torque control, physical human–robot interaction, and the dual-motor load sharing capability, demonstrating its suitability for rehabilitation exoskeleton applications.

2 October 2023 in IEEE Transactions on Visualization and Computer Graphics
Verified
Journal Article
Closed access
HZHongkun Zhang
Hongkun Zhang
KZKehong Zhou
Kehong Zhou
KSKe Shi
Ke Shi
YWYunhai Wang
Yunhai Wang
ASAiguo Song
Aiguo Song
LZLifeng Zhu
Lifeng Zhu
With the development of virtual reality, the practical requirements of the wearable haptic interface have been greatly emphasized. While passive haptic devices are commonly used in virtual reality, they lack generality and are difficult to precisely generate continuous force feedback to users. In this work, we present SmartSpring, a new solution for passive haptics, which is inexpensive, lightweight and capable of providing controllable force feedback in virtual reality. We propose a hybrid spring-linkage structure as the proxy and flexibly control the mechanism for adjustable system stiffness. By analyzing the structure and force model, we enable a smart transform of the structure for producing continuous force signals. We quantitatively examine the real-world performance of SmartSpring to verify our model. By asymmetrically moving or actively pressing the end-effector, we show that our design can further support rendering torque and stiffness. Finally, we demonstrate the SmartSpring in a series of scenarios with user studies and a just noticeable difference analysis. Experimental results show the potential of the developed haptic display in virtual reality

18 June 2025 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
YLYe Lu
Ye Lu
HLHuijun Li
Huijun Li
JLJianwei Lai
Jianwei Lai
JWJiajin Wang
Jiajin Wang
KSKe Shi
Ke Shi
ASAiguo Song
Aiguo Song
Magnetorheological actuator (MRA) exhibits complex nonlinear behaviors, including rate-dependence and creep, which pose challenges for accurate modeling. Existing differential-equation-based hysteresis models fail to accurately capture the complex characteristics of the MRA due to their single-dimensional approach. Therefore, this article proposes a novel multidimensional differential-equation-based hysteresis model to address this limitation. By adopting the multidimensional model structure, the proposed model significantly enhances performance. To effectively capture both rate-dependence and creep phenomena, a rate-dependent operator is introduced, and fractional calculus is employed to describe the creep compactly. Unlike existing models, the rate-dependence in the proposed operator originates from the differential equation’s structure rather than from adding dynamic factors or cascading functions. Furthermore, considering the numerical solution convergence of the differential-equation-based models, the parameter constraints are analyzed and incorporated into the parameter identification algorithm, which is neglected in the existing studies. The model’s effectiveness is validated through the theoretical analyses, the simulations, and the experimental verifications, demonstrating its capability to accurately capture both rate-dependence and creep phenomena in the MRA.

1 January 2025 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
KSKe Shi
Ke Shi
YGYingchen Gao
Yingchen Gao
MZMaozeng Zhang
Maozeng Zhang
LZLifeng Zhu
Lifeng Zhu
ASAiguo Song
Aiguo Song
Home-based rehabilitation with robot assistance may significantly reduce therapist workload and facilitate post-stroke patient training. However, the lack of real-time therapist supervision requires higher safety, ease of use, and training efficiency of the rehabilitation system. Therefore, active robot rehabilitation systems may not be particularly ideal for home use due to high costs, large footprints, safety concerns, and the potential for motor slacking. Self-powered robots provide a promising alternative by enabling the unimpaired side (UIS) to assist the impaired side (IS) without external power. However, constant and rigid coupling between limbs may lead to the over-compensation by the UIS, reduce engagement of the IS, and fail to provide sufficient information for task performance assessment. This paper demonstrates a home-based self-powered rehabilitation system with a variable stiffness mechanism (VSM), providing proper coupling stiffness between the UIS and IS according to the IS's motor ability. The application of the VSM also allows for the measurement of motion errors and interaction forces using only encoders, facilitating motor ability evaluation and training task guidance. First, we propose a cable-driven VSM with active and passive stiffness regulation, and develop a bilateral two-degree-of-freedom rehabilitation system with the VSM for evaluation. Then, the system's functionality and efficacy are validated through experiments with twelve healthy subjects and ten stroke survivors. The proposed self-powered system can potentially avoid UIS's over-compensation, enhances IS's engagement, and improves training efficiency, while ensuring safety and reliability within home-based rehabilitation.