Ye Li

Ye Li

Auto-generated profile, based on publicly available information

Ye Li

Southeast University

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YLYe Lu
Ye Lu
HLHuijun Li
Huijun Li
KSKe Shi
Ke Shi
JLJianwei Lai
Jianwei Lai
YLYe Li
Ye Li
ASAiguo Song
Aiguo Song
The tendon–sheath system (TSS) has emerged as a promising solution for force transmission in robot applications, owing to the lightweight, low inertia, and good flexibility. However, the performance of tension control is affected by the configuration-dependent nonlinearities, and achieving precise control of the distal force of TSS in time-varying configurations remains a challenge. To address this issue, this article proposes a comprehensive method combining feedforward and feedback control to enhance the control accuracy of TSS by estimating the bending angle in real time, even when the system configuration is unknown. A bending angle estimation approach based on a friction model is proposed, and an improved friction model is developed to simulate the nonlinear friction more accurately. Furthermore, a double-TSS transmission structure is designed to facilitate the integration of control and configuration feedback in mechanical systems. The experimental results confirm the effectiveness of the proposed method in enhancing force-tracking performance in unknown configurations.

1 February 2026 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
JLJianwei Lai
Jianwei Lai
ASAiguo Song
Aiguo Song
YLYe Lu
Ye Lu
PWPeiyang Wu
Peiyang Wu
WZWenbin Zhang
Wenbin Zhang
HWHongxing Wang
Hongxing Wang
Soft robots have gained recognition as promising solutions in rehabilitation robotics due to their intrinsic flexibility and safety features. However, they often encounter challenges related to output efficiency and portability. This paper presents the design, modeling, and evaluation of an innovative wrist rehabilitation robot that employs two double-layer lattice structure pneumatic actuators (DLSPAs) to enhance efficiency. Key parameters of these DLSPAs are optimized through a mathematical model, with calibration experiments indicating that the discrepancy between actual and predicted values remains within 4% of the DLSPAs' maximum output force, thereby validating the model's accuracy. Furthermore, the DLSPAs achieve an end output force of 27.02 N, marking a 156% increase compared to single-layer lattice structure pneumatic actuators (SLSPAs) and underscoring the structural advantages of the design. To evaluate the clinical efficacy of the wrist rehabilitation robot, trials were conducted with 8 individuals post-stroke. Results demonstrate that, with robotic assistance, participants' lifting force reached 4.85 N and 5.11 N in dorsal extension and palmar flexion, respectively, with corresponding angular movements of 36.40° and 38.36°. These findings suggest that the lattice-structured soft wrist rehabilitation robot offers substantial potential for effective assisted rehabilitation training.

27 June 2024
Verified
Conference Paper
Open access
MZMaozeng Zhang
Maozeng Zhang
HLHuijun Li
Huijun Li
KSKe Shi
Ke Shi
YLYe Li
Ye Li
ASAiguo Song
Aiguo Song
Upper limb rehabilitation robots have demonstrated substantial efficacy in enhancing limb motor function during the recovery process of stroke patients. The growing integration of compliance into the design of rehabilitation robot drive systems is motivated by concerns related to system stability and the safety of rehabilitation treatments. In our study, we developed a desktop bilateral rehabilitation robot (DBRR) aimed at assisting patients in their rehabilitation training while ensuring precise control over human-robot interaction forces. The drive system incorporates specially designed nonlinear rotary series elastic actuator (nrSEA). The stiffness range can passively vary from 0.13 Nm/° to 0.51 Nm/°. The stiffness profile and torque output performance of the nrSEA were rigorously validated through experiments conducted on the designated testing platform. At a frequency of 0.5 Hz, the root mean square error (RMSE) of the sinusoidal torque output is consistently less than 0.2 Nm, and the step response time at a 9 Nm amplitude is typically below 0.1 s. These experiments unequivocally demonstrate that the nrSEA exhibits exemplary characteristics in human-robot interaction torque control, rendering it highly suitable for applications in robot-assisted rehabilitation therapy.

17 November 2023
Verified
Conference Paper
Open access
JLJianwei Lai
Jianwei Lai
ASAiguo Song
Aiguo Song
YLYe Li
Ye Li
YLYe Lu
Ye Lu
KSKe Shi
Ke Shi
The application of robotics in the field of home rehabilitation training has revolutionized the way patients receive treatment. However, current rehabilitation robotic systems often lack diverse training methods and sufficient feedback channels, resulting in challenges for patients to sustain long-term engagement in rehabilitation training. This paper introduces a novel hand rehabilitation robot system that leverages virtual reality technology, multi-channel feedback technology, and mirror therapy to facilitate autonomous hand rehabilitation treatment for patients in a home setting. The system comprises a soft glove, a computer equipped with virtual interaction scenes, Leapmotion sensors, and a soft glove control box. To evaluate the usability and patient acceptance of the system, a clinical trial involving five patients was conducted. The trial results demonstrated noteworthy improvements in finger grip strength, with an increase from 8.74 ± 14.2 N to 17.82 ± 13.63 N when utilizing the soft glove. Furthermore, patients' upper extremity function assessment scale (ARAT) scores exhibited improvement from 12.4 ± 23.44 to 24.44 ± 25.89, and their functional ability for daily living (ADL) showed improvement from 43.8 ± 47.22 to 50.6 ± 43.24. These measurements indicated significant enhancements compared to the baseline, signifying that the proposed system did not compromise finger functionality. Additionally, the results of a user acceptance questionnaire, consisting of seven surveys administered to the patients, demonstrated a positive score of 4.18 ± 0.61 and a negative score of 0.95 ± 0.57. These outcomes reflect a high level of acceptance among patients, affirming the system's safety and effectiveness in providing a comfortable and reliable platform for rehabilitation training.


12 December 2025 in Mechatronics
Verified
Journal Article
Closed access
YLYe Li
Ye Li
ASAiguo Song
Aiguo Song
JLJianwei Lai
Jianwei Lai
YLYe Lu
Ye Lu
HLHuijun Li
Huijun Li