Sergio Spinato

Sergio Spinato

Auto-generated profile, based on publicly available information

Sergio Spinato

Private Practice Sassuolo Italy

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2019 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
SSSergio Spinato
Sergio Spinato
Claudio StacchiClaudio Stacchi
Claudio Stacchi
Teresa LombardiTeresa Lombardi
Teresa Lombardi
FBFabio Bernardello
Fabio Bernardello
MMMarcello Messina
Marcello Messina
DZDavide Zaffe
Davide Zaffe

29 May 2022 in Clinical Oral Implants Research
Verified
Journal Article
Open access
Claudio StacchiClaudio Stacchi
Claudio Stacchi
FBFabio Bernardello
Fabio Bernardello
SSSergio Spinato
Sergio Spinato
RMRossano Mura
Rossano Mura
MPmichele perelli
michele perelli
Luigi CanulloLuigi Canullo
Luigi Canullo
Objective: Clinical indications for maxillary sinus floor elevation with transcrestal techniques have increased in recent years even in sites with minimal residual bone height (RBH). Nevertheless, limited information is currently available on incidence of intraoperative complications and early implant failure in these cases.Material and Methods: This retrospective multicenter study was performed on anonymized clinical and radiographic records of patients who underwent transcrestal sinus floor elevation in seven clinical centers. Influence of different factors related to patient, and sinus anatomy and surgical technique on the incidence of intraoperative complications and early implant failure rate after transcrestal sinus lift were investigated.Results: A total of 430 patients treated with transcrestal sinus floor elevation for single‐implant insertion in sites with RBH ≤5 mm were included in the final analysis. After 1 year of loading, 418 implants of 430 were satisfactorily in function. Early implant failure was recorded in 12 cases (2.8%); results were significantly associated with the presence of large sinus cavities and with the occurrence of membrane perforation.The following adverse events were recorded: membrane perforation (7.2%), acute sinusitis (0.9%), implant displacement into the sinus cavity (0.7%), oro‐antral fistula (0.2%), and benign paroxysmal positional vertigo (0.5% of osteotome cases). A strong direct correlation between sinus membrane perforation and bucco‐palatal sinus width (p = .000) was demonstrated.Conclusions: Early implant failure after transcrestal sinus elevation showed significant direct correlation with bucco‐palatal maxillary sinus width and the presence of membrane perforation. Sinus membrane perforation was strongly associated with bucco‐palatal sinus width (extremely low perforation rate in narrow and much higher incidence in wide sinuses).

24 August 2022 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Open access
SSSergio Spinato
Sergio Spinato
FBFabio Bernardello
Fabio Bernardello
Teresa LombardiTeresa Lombardi
Teresa Lombardi
CSCarlo Maria Soardi
Carlo Maria Soardi
MMMarcello Messina
Marcello Messina
Claudio StacchiClaudio Stacchi
Claudio Stacchi
Introduction: Supracrestal tissue height establishment is a crucial factor influencing peri‐implant marginal bone modifications prior to prosthesis delivery. If mucosal thickness is insufficient, peri‐implant marginal bone resorption occurs to allow appropriate supracrestal tissue height formation. This study evaluates if marginal bone resorption occurring around tissue‐level implants before prosthetic loading could be compensated by adapting apico‐coronal positioning to mucosal thickness.Methods: Patients requiring placement of one single implant in the posterior mandible were treated with tissue‐level implants with a 3‐mm high transmucosal machined component and moderately rough implant body. Based upon vertical mucosal thickness measured after buccal flap reflection, implants were placed with the treated part: (group 1) 2 mm below crestal level in presence of thin mucosa (3.5 mm).Results: Forty‐nine implants, placed in 49 patients were included in final analysis (group 1: 18 implants; group 2: 16 implants; group 3: 15 implants). Mean marginal bone resorption after 5 months of healing was 0.66 ± 0.49 mm, 0.32 ± 0.41 mm, and 0.22 ± 0.52 mm in groups 1, 2, and 3, respectively. Inter‐group analysis highlighted significant differences between the three groups after ANOVA test (p = 0.025). However, adaptation of apico‐coronal implant positioning in relation to mucosal thickness, allowed to avoid early exposure of the treated surface in 100%, 93.7%, and 53.3% of the implants in groups 1, 2, and 3, respectively.Conclusion: During supracrestal tissue height formation, tissue‐level implants inserted adapting apico‐coronal positioning in relation to mucosal thickness exhibited greater marginal bone resorption at sites with thin mucosa than at sites with medium or thick mucosa. However, anticipating supracrestal tissue height establishment by adapting apico‐coronal implant positioning in relation to mucosal thickness may effectively prevent unwanted exposure of treated implant surface.

11 June 2025 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Open access
SSSergio Spinato
Sergio Spinato
FBFabio Bernardello
Fabio Bernardello
Claudio StacchiClaudio Stacchi
Claudio Stacchi
CSCarlo Maria Soardi
Carlo Maria Soardi
MMMarcello Messina
Marcello Messina
Teresa LombardiTeresa Lombardi
Teresa Lombardi
Introduction: Early marginal bone loss (EMBL) is a non‐infective phenomenon occurring around the implant neck from placement to the first year of prosthetic function, being influenced by both surgical and prosthetic factors. This multi‐center prospective study assesses the impact of different variables potentially influencing marginal bone stability during the period from crown delivery to 18 months of functional loading.Methods: Forty‐seven patients requiring a single posterior mandibular implant were selected according to specific criteria. Tissue‐level implants were placed at different crestal bone levels based on vertical mucosal thickness and followed in an unsubmerged healing protocol, as described in a previous study evaluating peri‐implant bone levels (PBL) from implant placement (T0) to crown delivery (T1). The present study continues this evaluation, focusing on MBL from T1 to 18 months post‐loading (T2). Host‐related factors (age, gender, smoking, history of periodontitis, vertical mucosal thickness) and specific prosthetic parameters, including crown mesio‐distal dimension, emergence angle, and transmucosal collar height were recorded. Multiple linear regression analysis explored associations between MBL and prosthetic or patient‐related factors, with significance set at p < 0.05.Results: Marginal bone levels remained stable from T1 to T2, with no significant association between MBL and host‐related factors or defined prosthetic variables. However, total MBL from T0 to T2 was significantly higher around implants with thin mucosa at T0 compared to medium and thick mucosa. Multivariate analysis (T0‐T2) identified thin mucosa and smoking as significant MBL predictors.Conclusion: From T1 to T2, marginal bone levels around tissue‐level implants remain stable, with no significant influence from variables analyzed. Conversely, peri‐implant bone resorption between T0 and T2 is significantly associated with thin mucosa (primarily affecting T0‐T1) and smoking.Trial Registration: www.clinicaltrials.gov: NCT05363306