With the development of partially prestressing technique, the application of prestressed concrete was extended to protective structures. Despite those known advantages of higher crack resistance, higher solidity and lighter weight, the absence of systematic, theoretical investigations, as well as simple analytical methods in prestressed structures demonstrate a drawback in design and assessment of blast-resistant structures. An approach based on the layered section method was presented in this paper to predict the static resistance-deflection curves of partially prestressed concrete beam-slab structures, and it was validated by test data. Based on the layered section method for static analysis, a new analytical method was proposed to investigate the dynamic responses of the partially prestressed concrete beams subjected to blast loads. The new method incorporated an elasto/viscoplastic rate-sensitive model with the proposed analytical approach for static analysis into an equivalent single degree of freedom (SDOF) system. The analytical results agreed well with the test data. And some main affecting factors on the dynamic responses of the structures were discussed. It is demonstrated that the dynamic resistance of partially prestressed concrete structures is improved with the increasing of initial prestressing force and partially prestressing ratio (PPR).
1 October 2008 in Transactions of Tianjin University
Liquefied natural gas (LNG) leaks often lead to cascading accident disasters, including vapor cloud release, explosion, fire, and toxic gas release. The origin and evolution of each accidental disaster must be considered when assessing safety. This paper discusses the safety assessment project of an LNG gas storage station in Xuzhou, China. Multiple conceivable disasters due to the leakage of LNG storage tanks are simulated and analyzed using the computational fluid dynamic software FLACS. We studied different wind speeds interacting with the flammable vapor cloud area and creating frostbite in areas of low temperature. Diffusion simulations of vapor cloud explosion (VCE), thermal radiation, and the distribution of toxic substances were performed. The overpressure‐impulse criterion was used to calculate the influence range of VCE. Heat flux, heat dose, and heat flux‐heat dose criteria were used to calculate the safe distance for personnel in the event of fire. Based on the calculation results of the three latter criteria, this paper recommends using the heat flux criterion to evaluate fire accidents. The danger zone of each accident was compared. VCE accidents yielded the largest area.
In order to improve the anti-collision capacity of existing reinforced concrete (RC) columns under vehicle impact load, an experimental study on the anti-collision performance of RC columns strengthened with micro-expansive concrete filled steel tube was carried out. By combining an experiment and finite element calculation, the influence of steel tube strength, micro-expansive concrete strength and steel tube wall thickness on the anti-collision performance of strengthened RC columns were studied. The results showed that the peak displacement of an SM-RC column is 25.9% lower than that of an RC column, due to the increased stiffness, the peak impact force increased by 138.2%. The micro-expansive concrete filled steel tube reinforcement method can significantly improve the anti-collision performance of RC columns and reduce the lateral deformation. Increasing the strength grade of steel tube and thickness of steel tube can greatly improve the impact resistance of strengthened RC columns and reduce the lateral deflection deformation of short columns, compared with steel tube strength Q235, the displacement of Q690 is reduced 47.4%. the displacement of the 8-mm thick steel tube is reduced by 48.1% compared with the 4-mm one. while the strength grade of micro-expansive concrete has little effect on the impact resistance and lateral deflection deformation of strengthened RC columns.