6 November 2023 in IEEE Photonics Journal
Signal-to-noise ratio (SNR) analysis is a crucial component of optical system development for space remote sensing instruments. It serves as a quantitative assessment of the imaging quality and radiometric characteristics of space remote sensing. This paper utilizes the working principles and energy transfer principles of space remote sensing instruments to conduct SNR analysis and model development for commonly used spaceborne imagers, spaceborne imaging spectrometers, micro-optical remote sensing instruments, and point-source spatial targets. Additionally, the paper also examines the impact of the presence and width of slits in different space environments on the SNR of space remote sensing instruments. The calculation results indicate that the analysis of Signal-to-Noise Ratio (SNR) for different space remote sensing instruments requires the establishment of distinct SNR models. The magnitude of SNR primarily depends on crucial factors such as optical system quality, detector performance, and the space environment. Therefore, in the instrument design and data processing processes, it is essential to consider how to maximize SNR and establish more accurate corresponding SNR models to provide high-quality remote sensing data.
8 March 2024 in Optics Communications
1 January 2024 in IEEE Photonics Technology Letters
In the currently deployed scheme utilizing Acousto-Optic Tunable Filter (AOTF) in conjunction with the echelle grating, the maximum spectral overlap for low diffraction orders exceeds 2/3, while encountering the issue of spectral discontinuity at higher diffraction orders. We propose a method to address the issue of image plane order overlap in echelle imaging spectrometers. This method utilizes the principle of matching the spectral resolution of the AOTF with the free spectral range of the echelle to eliminate order overlap, while ensuring that there are no gaps between the spectral bands in each output. With this method, we recalculate the spectral bands corresponding to the orders of the echelle and make enhancements to the imaging spectrometer based on the calculation results. The results of the design show that the improved imaging spectrometer has excellent imaging quality, validating the effectiveness and practicality of this method.
13 February 2026 in SSRN Electronic Journal
To overcome the shortcomings of traditional Czerny-Turner (C-T) spectrometers—such as significant optical aberrations, low spatial resolution, and image quality degradation over time. This paper proposes an optical aberration correction design method for C-T imaging spectrometers based on an externally mounted transmissive Schmidt correction module. The method involves placing a Schmidt corrector plate at the front end of the telescope to correct the aberrations of the overall optical system. Accordingly, a spaceborne C-T imaging spectrometer optical system was designed with a 3.4° field of view, 60mm focal length, F-number(F#) of 5, and an operating spectral range of 400~700nm. The optical design software CODEV was used for ray tracing, optimization, and performance analysis. The results show that the addition of the external Schmidt corrector effectively corrects the system's aberrations. Across the full field of view, the modulation transfer function (MTF) remains above 0.7 at the Nyquist frequency of 38.46 lp/mm, approaching the diffraction limit and meeting all design requirements. These findings demonstrate the feasibility of the proposed optical design method, which offers a reliable technical approach for post-deployment maintenance, aberration correction, and service life extension of remote sensing instruments.