Huiyan Zhang

Huiyan Zhang

Auto-generated profile, based on publicly available information

Huiyan Zhang

Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang 212013, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2022 in Processes
Verified
Journal Article
Open access
PDF file
HZHuiyan Zhang
Huiyan Zhang
FMFan Meng
Fan Meng
LCLei Cao
Lei Cao
YLYanjun Li
Yanjun Li
XWXinkun Wang
Xinkun Wang
In this study, entropy generation theory based on computational fluid dynamics (CFD) is used to study the influence of a pumping chamber type (guide vane and volute scheme) on the spatial distribution of hydraulic loss in a mixed-flow pump. The CFD data of the mixed-flow pump with a volute is validated by external characteristic test data under Q = 561.4–1598.6 m3/h. The results show that the efficiency and the head of the guide vanes scheme are lower under Q = 800–1200 m3/h, which resulted from a higher total entropy production (TEP) in the pumping chamber and outlet pipe. The high total entropy production rate (TEPR) inside the guide vanes can be found near the leading edge of the hub side and trailing edge of the rim side due to flow separation, which reduces the recovery efficiency of kinetic energy of the guide vanes. The high TEPR inside outlet pipe can be seen near the inlet, caused by back flow. However, the efficiency and head of the volute scheme are lower, under Q = 1200–1600 m3/h, owing to the fact that the volute cannot effectively convert kinetic energy into pressure energy and thus the high TEPR can be found near outlet of volute and inlet of outlet pipe. These results can provide useful suggestions to the matching optimization of the impeller and pumping chamber in a mixed-flow pump.

30 November 2021 in Machines
Verified
Journal Article
Open access
PDF file
HZHuiyan Zhang
Huiyan Zhang
FMFan Meng
Fan Meng
YZYunhao Zheng
Yunhao Zheng
YLYanjun Li
Yanjun Li
To reduce cavitation-induced pressure fluctuations in a mixed-flow pump under impeller inflow distortion, the dynamic pressure signal at different monitoring points of a mixed-flow pump with a dustpan-shaped inlet conduit under normal and critical cavitation conditions was collected using high-precision digital pressure sensors. Firstly, the nonuniformity of the impeller inflow caused by inlet conduit shape was characterized by the time–frequency-domain spectra and statistical characteristics of pressure fluctuation at four monitoring points (P4–P7) circumferentially distributed at the outlet of the inlet conduit. Then, the cavity distribution on the blade surface was captured by a stroboscope. Lastly, the characteristics of cavitation-induced pressure fluctuation were obtained by analyzing the time–frequency-domain spectra and statistical characteristic values of dynamic pressure signals at the impeller inlet (P1), guide vanes inlet (P2), and guide vanes outlet (P3). The results show that the flow distribution of impeller inflow is asymmetric. The pav values at P4 and P6 were the smallest and largest, respectively. Compared with normal conditions, the impeller inlet pressure is lower under critical cavitation conditions, which leads to low pav, pp-p and a main frequency amplitude at P1. In addition, the cavity covered the whole suction side under H = 13.6 m and 15.5 m, which led the pp-p and dominant frequency amplitude of pressure fluctuation at P2 and P3 under critical cavitation to be higher than that under normal conditions.

1 March 2024 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
YZYunhao Zheng
Yunhao Zheng
YLYanjun Li
Yanjun Li
Xingye ZhuXingye Zhu
Xingye Zhu
SYShouqi Yuan
Shouqi Yuan
HZHuiyan Zhang
Huiyan Zhang
HWHongliang Wang
Hongliang Wang
A two-way pumping station is a specialized device that facilitates bidirectional water pumping and drainage. The pressure pulsation characteristics of two-way pumping stations have emerged as a prominent research focus in the field of hydraulic engineering. In this work, with the aim of systematically proposing optimization measures to ensure operational stability, a transient numerical simulation is conducted to elucidate the influence mechanism of the suspension height of the bell mouth (SHb) on the internal flow field and pressure pulsation of a two-way pumping station. High-precision experiments are performed to compare time-frequency domain characteristics under different SHb using a continuous wavelet transform (CWT). The findings indicate that an appropriate reduction in SHb effectively reduces unstable flow and pressure pulsation within the inlet conduit, consequently reducing the pressure pulsation of the impeller. With a reduction in SHb, the influx of low-velocity backflow into the bell mouth is prevented and the generation and propagation of suction vortices are suppressed. However, the reduction amplifies the flow impact between the mainstream flow and the bell mouth wall. The spatial distribution of the pressure pulsation is also examined, and it is found that a reduction in SHb increases the pressure pulsation intensity on the side facing the incoming flow and on the rear side, while the mainstream area tends to exhibit stability. In terms of time-frequency domain characteristics, a reasonable reduction in SHb leads to improved circumferential uniformity of the impeller inflow and the effective suppression of low-frequency disturbances.