Anna De Cet

Anna De Cet

Auto-generated profile, based on publicly available information

Anna De Cet

Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2025 in Acta Materialia
Verified
Journal Article
Open access
LDLuca D'Andrea
Luca D'Andrea
RGRoberta Gabrieli
Roberta Gabrieli
LMLorenzo Milano
Lorenzo Milano
LLuca Magagnin
Luca Magagnin
ACAnna De Cet
Anna De Cet
Pasquale VenaPasquale Vena
Pasquale Vena

8 July 2025 in Journal of Mechanics in Medicine and Biology
Verified
Journal Article
Closed access
IRIlaria Rota
Ilaria Rota
Nadim OlivaNadim Oliva
Nadim Oliva
ACAnna DE Cet
Anna DE Cet
MCMartina Colombo
Martina Colombo
ASAndrea Sardella
Andrea Sardella
DGDario Gastaldi
Dario Gastaldi

16 March 2026 in Medical & Biological Engineering & Computing
Verified
Journal Article
Open access
PDF file
ACAnna De Cet
Anna De Cet
MCMartina Colombo
Martina Colombo
LDLuca D'Andrea
Luca D'Andrea
IRIlaria Rota
Ilaria Rota
LBLuigi La Barbera
Luigi La Barbera
DGDario Gastaldi
Dario Gastaldi
Fusion surgery involves replacing degenerated intervertebral discs with artificial implants, usually composed of titanium alloys or PEEK, requiring bone grafting to assist tissue growth. This study aims to evaluate numerically 3D-printed porous ceramic implants as a bioactive alternative. Clinical computed tomographies of an adult patient were used to reconstruct the geometry and to assign mechanical properties to L1 and L2 vertebrae, utilizing a patient-specific anisotropic micromechanics-based model. The influence of different microstructural choices on a porous hydroxyapatite-based scaffold was analysed through finite element analysis, simulating standing and flexion. The analyzed scaffolds included: microstructured Face Centered Cubic (FCC) and Kelvin-based devices with uniform porosity (75%), and a Voronoi microstructured scaffold with uniform (75%) and graded porosity (60% external, 90% internal). Homogenized models were considered as a potential strategy to reduce computational costs. The FCC geometry and graded Voronoi proved more mechanically resistant to failure. Homogenized mechanical properties simplified the model, but didn’t accurately represent microstructural behaviour and local mechanical failure couldn’t be suitably identified. Patient-specific models allowed for a more accurate representation of mechanical stresses, leading to a reduced risk of structural failure. Hydroxyapatite proves to be a promising material for 3D-printed lumbar interbody fusion cages, able to provide primary stability.

9 July 2026 in Biomimetics
Verified
Journal Article
Open access
PDF file
Hajar SouhailHajar Souhail
Hajar Souhail
LDLuca D'Andrea
Luca D'Andrea
ACAnna De Cet
Anna De Cet
DRDavide Ruffoni
Davide Ruffoni
Pasquale VenaPasquale Vena
Pasquale Vena
Hydroxyapatite-based ceramic scaffolds are attractive for bone tissue engineering but are prone to brittle fracture during screw fixation. This study addresses the challenge of tuning local toughness in the peri-screw region of brittle ceramic scaffolds. Inspired by the presence of voids in many load-bearing biological materials, we explored how micro-pores interact with cracks to modulate fracture toughness. A circular scaffold is considered, featuring a central hole to accommodate the screw and a notch to trigger fracture. The scaffold was analysed under radial compression, using finite element simulations based on a phase field formulation for brittle fracture. The influence of notch size on crack propagation was first investigated and compared with the behavior of a plate under mode I failure. Subsequently, the influence of micro-pore shape and spatial arrangement on strength and toughness was examined. Results showed that the circular scaffold attenuates notch sensitivity when compared to the plate-like scaffold, due to the interplay between circumferential tension and radial compression. Circular pores increased energy dissipation through crack deflection and they decreased the strength due to stress concentration. Elongated pores preserved strength by mitigating these stress peaks. These findings identify key geometric parameters for optimizing the mechanical reliability of ceramic scaffolds requiring screw fixation.