Piotr Buliński

Piotr Buliński

Auto-generated profile, based on publicly available information

Piotr Buliński

Silesian Tech Univ, Inst Thermal Technol, Gliwice, Poland

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2019 in Applied Thermal Engineering
Verified
Journal Article
Closed access
PBPiotr Buliński
Piotr Buliński
JSJacek Smolka
Jacek Smolka
GSGrzegorz Siwiec
Grzegorz Siwiec
LBLeszek Blacha
Leszek Blacha
SGSławomir Golak
Sławomir Golak
BMBartlomiej Melka
Bartlomiej Melka

1 January 2015 in Scientific Letters of Rzeszow University of Technology - Mechanics
Verified
Journal Article
Open access
ZOZiemowit Ostrowski
Ziemowit Ostrowski
PBPiotr Buliński
Piotr Buliński
WAWojciech Adamczyk
Wojciech Adamczyk
PKPaweł Kozołub
Paweł Kozołub
Andrzej J. NowakAndrzej J. Nowak
Andrzej J. Nowak

1 November 2021 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
PBPiotr Buliński
Piotr Buliński
JSJacek Smolka
Jacek Smolka
SGSławomir Golak
Sławomir Golak
RPRoman Przyłucki
Roman Przyłucki
MPMichał Palacz
Michał Palacz
LBLeszek Blacha
Leszek Blacha

2 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
MTMieszko Tokarski
Mieszko Tokarski
ARArkadiusz Ryfa
Arkadiusz Ryfa
PBPiotr Buliński
Piotr Buliński
MRMarek Rojczyk
Marek Rojczyk
KZKrzysztof Ziarko
Krzysztof Ziarko
Andrzej J. NowakAndrzej J. Nowak
Andrzej J. Nowak
The development of a numerical model and design for the innovative construction of a heat exchanger (HE) used in a condensation hood (being a part of the combi-steamer) are described in this work. The model covers an air-steam flow, heat transfer, and a steam condensation process. The last two processes were implemented with the use of an in-house model introduced via User Defined Functions (UDF). As the condensate volume is negligible compared to the steam, the proposed model removes the condensate from the domain. This approach enabled the usage of a single-phase flow for both air and steam using a species transport model. As a consequence, a significant mesh and computation time reduction were achieved. The new heat exchanger is characterised by reorganised fluid flow and by externally finned pipes (contrary to the original construction, where internally finned pipes were used). This allowed a reduction in the number of the pipes from 48 to 5, which significantly simplifies construction and manufacturing process of the HE. The redesigned HE was tested in two cases: one simulating normal working conditions with a combi-steamer, the other with extremely high heat load. Measurement data showed that the numerical model predicted condensate mass flow rate (3.67 g/s computed and 3.56 g/s measured) and that the condensation capability increased at least by 15% when compared to the original HE design.