17 June 2021 in IEEE Transactions on Microwave Theory and Techniques
To overcome the multipath interference in locating transient electromagnetic (EM) radiation sources in an indoor environment, we propose a criterion that calculates the correlation between back-propagated signals from observation points, to be used in EM time reversal (EMTR) algorithms. The method introduced in this article has three main advantages with respect to classical methods that use full-wave simulations and other criteria, such as maximum field strength. First, compared with full-wave techniques in the back-propagation phase, the proposed correlation-based method utilizes approximated transfer functions from the ray-tracing technique, which can improve the computation efficiency. Second, an inverted-loss model is used for the back-propagation, which could reduce the localization error caused by multipath effects due to signal attenuation and time delay. Third, the proposed correlation criterion has weak correlation with the source characteristics, which makes it applicable to the localization in indoor reflective environments with only two observation points. Several numerical simulations are carried out to assess the performance of the proposed method. The results indicate that the proposed correlation-based EMTR technique is able to locate radiation sources accurately and efficiently in indoor reflective environments.
28 March 2019 in IEEE Transactions on Instrumentation and Measurement
An electric field (E-field) detector with the features of precise time base, full waveform storage and wireless data transmission has been developed, which can be used in combination with location algorithm for accurate location of the transient electromagnetic radiation source over a large-scale area. The maximum sampling rate is 2 GS/s and the memory depth is up to 128 kByte and can be adjustable. The measurement range can be adjusted from hundreds of V/m to tens of kV/m with different lengths of antennas. With the help of Global Positioning System (GPS), both the clock and the position of the detector can be synchronized. Particularly, the time instant triggered by the signal could be recorded with the time resolution of ten nanoseconds. Therefore, the precise time base alignment among multiple detectors could be achieved, which is crucial for location accuracy. Then, all data including the signal, the position and the time instant could be sent to a remote server by Fourth-generation mobile (4G) communication technology. The calibration results show that the bandwidth of the detector could vary from 10 kHz to 500 MHz, while the time base alignment error between any two detectors is less than 50 ns. An experiment was performed by means of electromagnetic time reversal (EMTR) method to prove the applicability of the detector and its location accuracy. The detector could be used to measure and locate lightning, partial discharge or fault, etc.
30 April 2020 in IEEE Transactions on Instrumentation and Measurement
Based on multi-gap loop (MGL) antenna and low-noise norm detector, a novel nano-second (ns) level transient magnetic field (H-field) sensor is proposed in this paper. The direct measurement result of the MGL antenna is the differential signal of the H-field, which is capable to be digitized for storage by the norm detector. The original H-field can be restored using the software integral method. The developed ns-level H-field sensor exhibits two major advantages. Firstly, it can measure the H-field in the substation or the coupled H-field inside the hermetically sealed cavities, such as the cockpit of vehicles or aircrafts, which is because the need for transmission line is removed. Secondly, its sensitivity is significantly higher than the measurement system with the hardware passive integrator and the integral error can also be effectively reduced by the low-noise norm detector. In this paper, the realization of the ns-level transient H-field sensor will be detailed. The simulated upper cut-off frequency of the designed MGL antenna is about 1.9 GHz. The sampling rate of the norm detector is 2 GS/s as the maximum. The dynamic range of the detector is about 42 dB and the operation bandwidth ranges from 0.3 kHz to 500 MHz by calibration. The total storage space of 128 kB can record as long as 64 μs at 2 GS/s and is extendable. Test results show that the developed sensor can measure the ns-level H-field accurately.
4 February 2020 in IEEE Transactions on Electromagnetic Compatibility
Traditional location methods such as time of arrival and direction of arrival have been widely used to locate transient radiation sources. However, these approaches neglect the directional radiation pattern of the sources. Locating directional sources is a complicated task because the waveform and the amplitude of radiated signals in the time domain vary for different directions. In this article, the ability of the electromagnetic time reversal (EMTR) technique to locate directional sources is investigated. As a typical directional source, the impulse radiation antenna (IRA) is used to validate the method. A radiation model is first established, and the time reversal procedure is carried out in the frequency domain. The amplitude of the signals is kept constant in the reverse phase in order to eliminate the distance attenuation. After analyzing the characteristics of directionality, we choose the energy criterion to estimate the position of the source since the time reversed signals would add up in phase only at the position of the source. It is shown that the point with the maximum energy of the synthesized signal corresponds to the position of the source. Numerical validations are presented and the relationship between the spatial resolution and the influencing factors such as the central frequency and the bandwidth of the excitation, the background noise level, the baseline length, and the number of sensors, are discussed in this article. Experimental results in an anechoic chamber with an impulse radiation antenna as the radiator and multiple horn antennas as the receivers are presented which confirm the ability of the EMTR-based method to locate directional radiation sources. Furthermore, we show that the location accuracy obtained with the energy criterion is better than that obtained with the ∞-norm criterion in the considered scenarios.