Lightning discharges between charged clouds and the Earth’s surface are responsible for considerable damages and casualties. It is therefore important to develop better protection methods in addition to the traditional Franklin rod. Here we present the first demonstration that laser-induced filaments—formed in the sky by short and intense laser pulses—can guide lightning discharges over considerable distances. We believe that this experimental breakthrough will lead to progress in lightning protection and lightning physics. An experimental campaign was conducted on the Säntis mountain in north-eastern Switzerland during the summer of 2021 with a high-repetition-rate terawatt laser. The guiding of an upward negative lightning leader over a distance of 50 m was recorded by two separate high-speed cameras. The guiding of negative lightning leaders by laser filaments was corroborated in three other instances by very-high-frequency interferometric measurements, and the number of X-ray bursts detected during guided lightning events greatly increased. Although this research field has been very active for more than 20 years, this is the first field-result that experimentally demonstrates lightning guided by lasers. This work paves the way for new atmospheric applications of ultrashort lasers and represents an important step forward in the development of a laser based lightning protection for airports, launchpads or large infrastructures.
In this work, we present a novel technique to locate partial discharge (PD) sources based on the concept of time reversal. The localization of the PD sources is of interest for numerous applications, including the monitoring of power transformers, Gas Insulated Substations, electric motors, super capacitors, or any other device or system that can suffer from PDs. To the best of the authors’ knowledge, this is the first time that the concept of time reversal is applied to localize PD sources. Partial discharges emit both electromagnetic and acoustic waves. The proposed method can be used to localize PD sources using either electromagnetic or acoustic waves. As a proof of concept, we present only the results for the electromagnetic case. The proposed method consists of three general steps: (1) recording of the waves from the PD source(s) via proper sensor(s), (2) the time-reversal and back-propagation of the recorded signal(s) into the medium using numerical simulations, and (3) the localization of focal spots. We demonstrate that, unlike the conventional techniques based on the time difference of arrival, the proposed time reversal method can accurately localize PD sources using only one sensor. As a result, the proposed method is much more cost effective compared to existing techniques. The performance of the proposed method is tested considering practical scenarios in which none of the former developed methods can provide reasonable results. Moreover, the proposed method has the unique advantage of being able to locate multiple simultaneous PD sources and doing so with a single sensor. The efficiency of the method against the variation in the polarization of the PDs, their length, and against environmental noise is also investigated. Finally, the validity of the proposed procedure is tested against experimental observations.
1 February 2018 in IEEE Transactions on Electromagnetic Compatibility
Electromagnetic time reversal (EMTR) has emerged as a promising technique to locate disturbances in power grids, thanks to its location accuracy and robustness against parameters uncertainties. Furthermore, in a reflective medium, like the one of a power network, it has been shown that the method requires no more than one single observation point. In this paper, we present an experimental validation of EMTR to locate disturbances in real power networks. The validation is performed on a full-scale unenergized 677-m-long, double-circuit 10-kV overhead distribution line. The disturbance is emulated by a voltage pulse injected between one of the line conductors and the ground using a high-voltage pulse generator. The frequency spectrum of the injected voltage pulse is specified such that the originated electromagnetic transients are compatible with those of power line faults, lightning, and conducted intentional electromagnetic interferences. The transient currents generated by the emulated disturbance are measured at one end of the line, considering two different line configurations. According to the EMTR technique, the measured signals are time reversed and back injected into the system that, in our case, is a simulated model of the considered distribution line. More specifically, it is represented by a constant-parameter line model implemented within the EMTP-RV simulation environment. For both cases, the disturbance is accurately located, and the phase of the circuit at which the pulse was injected is also identified.
18 October 2017 in Journal of Geophysical Research: Atmospheres
In this paper, we analyze the location error of time of arrival (ToA)‐based lightning location systems (LLSs) caused by propagation effects over mountainous terrain around the Säntis tower located in the Swiss Alps. The study is based on a full‐wave three‐dimensional (3‐D) finite difference time domain approach using the topographic map including the Säntis tower and the nearby sensors belonging to LLSs. It is found that the vertical electric fields are strongly affected by the presence of the mountainous terrain and the finite ground conductivity and that the location error associated with the ToA technique depends strongly on the used onset time estimation technique. The evaluated location errors associated with amplitude thresholds of 10% and 20% and the time of the linear extrapolation of the tangent at maximum field derivative are found to be smallest (about 300 m or less). Finally, we assess the accuracy of two simplified methods (terrain envelope method and tight‐terrain‐fit method) to account for the location error due to propagation over mountainous terrain. These two methods might represent an efficient alternative to estimate the additional time delay due to propagation over a nonflat terrain by using available topographic data. In addition, a possible real‐time location error compensation algorithm using the elongated propagation path method to improve the location error of the LLSs in mountainous regions is presented and discussed.
1 January 2020 in IEEE Transactions on Industrial Electronics
In this paper, we propose and implement a novel technique to locate Electromagnetic Interference (EMI) sources using the concept of time reversal cavity. We show in an intuitive manner that reflections from the surfaces of a cavity can emulate an infinite number of sensors in the Time Reversal (TR) method. In order to locate EMI sources, the equipment under test (EUT) is placed in a rectangular metallic cavity, of suitable dimensions according to the considered frequency band and the EUT size, equipped with a simple monopole or dipole antenna. We demonstrate that, by using only one sensor, we are able to locate EMI sources by taking advantage of the focusing properties of a time reversal cavity. The entropy criterion is applied to obtain the focusing time slice in which the maximum electric field determines the location of the EMI source. Both two- and three-dimensional numerical simulation schemes are deployed to demonstrate the ability of the proposed technique. The validity of numerical simulations is tested against frequency domain measurements. Compared to conventional EMI tests in anechoic chambers and scanning methods, the proposed technique represents a simpler and cost-effective test method requiring only one sensor (a monopole or dipole antenna).
26 April 2018 in Journal of Geophysical Research: Atmospheres
We present a study on the characteristics of current and electric field pulses associated with upward lightning flashes initiated from the instrumented Säntis Tower in Switzerland. The electric field was measured 15 km from the tower. Upward flashes always begin with the initial stage composed of the upward‐leader phase and the initial‐continuous‐current (ICC) phase. Four types of current pulses are identified and analyzed in the paper: (1) return‐stroke pulses, which occur after the extinction of the ICC and are preceded by essentially no‐current time intervals; (2) mixed‐mode ICC pulses, defined as fast pulses superimposed on the ICC, which have characteristics very similar to those of return strokes and are believed to be associated with the reactivation of a decayed branch or the connection of a newly created channel to the ICC‐carrying channel at relatively small junction heights; (3) “classical” M‐component pulses superimposed on the continuing current following some return strokes; and (4) M‐component‐type ICC pulses, presumably associated with the reactivation of a decayed branch or the connection of a newly created channel to the ICC‐carrying channel at relatively large junction heights. We consider a data set consisting of 9 return‐stroke pulses, 70 mixed‐mode ICC pulses, 11 classical M‐component pulses, and 19 M‐component‐type ICC pulses (a total of 109 pulses). The salient characteristics of the current and field waveforms are analyzed. A new criterion is proposed to distinguish between mixed‐mode and M‐component‐type pulses, which is based on the current waveform features. The characteristics of M‐component‐type pulses during the initial stage are found to be similar to those of classical M‐component pulses occurring during the continuing current after some return strokes. It is also found that about 41% of mixed‐mode ICC pulses were preceded by microsecond‐scale pulses occurring in electric field records some hundreds of microseconds prior to the onset of the current, very similar to microsecond‐scale electric field pulses observed for M‐component‐type ICC pulses and which can be attributed to the junction of an in‐cloud leader channel to the current‐carrying channel to ground. Classical M‐component pulses and M‐component‐type ICC pulses tend to have larger risetimes ranging from 6.3 to 430 μs. On the other hand, return‐stroke pulses and mixed‐mode ICC pulses have current risetimes ranging from 0.5 to 28 μs. Finally, our data suggest that the 8‐μs criterion for the current risetime proposed by Flache et al. is a reasonable tool to distinguish between return strokes and classical M‐components. However, mixed‐mode ICC pulses superimposed on the ICC can sometimes have considerably longer risetimes, up to about 28 μs, as observed in this study.