Thomas Ursby

Thomas Ursby

Auto-generated profile, based on publicly available information

Thomas Ursby

Max IV Laboratory, Lund University, Fotongatan 2, Lund 224 84, Sweden

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2020 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
TUThomas Ursby
Thomas Ursby
KÅKarl Åhnberg
Karl Åhnberg
RARoberto Appio
Roberto Appio
OAOskar Aurelius
Oskar Aurelius
ABArtur Barczyk
Artur Barczyk
UMUwe Mueller
Uwe Mueller
BioMAX is the first macromolecular crystallography beamline at the MAX IV Laboratory 3 GeV storage ring, which is the first operational multi-bend achromat storage ring. Due to the low-emittance storage ring, BioMAX has a parallel, high-intensity X-ray beam, even when focused down to 20 µm × 5 µm using the bendable focusing mirrors. The beam is tunable in the energy range 5–25 keV using the in-vacuum undulator and the horizontally deflecting double-crystal monochromator. BioMAX is equipped with an MD3 diffractometer, an ISARA high-capacity sample changer and an EIGER 16M hybrid pixel detector. Data collection at BioMAX is controlled using the newly developed MXCuBE3 graphical user interface, and sample tracking is handled by ISPyB. The computing infrastructure includes data storage and processing both at MAX IV and the Lund University supercomputing center LUNARC. With state-of-the-art instrumentation, a high degree of automation, a user-friendly control system interface and remote operation, BioMAX provides an excellent facility for most macromolecular crystallography experiments. Serial crystallography using either a high-viscosity extruder injector or the MD3 as a fixed-target scanner is already implemented. The serial crystallography activities at MAX IV Laboratory will be further developed at the microfocus beamline MicroMAX, when it comes into operation in 2022. MicroMAX will have a 1 µm × 1 µm beam focus and a flux up to 1015 photons s−1 with main applications in serial crystallography, room-temperature structure determinations and time-resolved experiments.

14 October 2023 in IUCrJ
Verified
Journal Article
Open access
PDF file
FLFilip Leonarski
Filip Leonarski
JNJie Nan
Jie Nan
ZMZdenek Matej
Zdenek Matej
QBQuentin Bertrand
Quentin Bertrand
AFAntonia Furrer
Antonia Furrer
FDFlorian Dworkowski
Florian Dworkowski
Serial and time-resolved macromolecular crystallography are on the rise. However, beam time at X-ray free-electron lasers is limited and most third-generation synchrotron-based macromolecular crystallography beamlines do not offer the necessary infrastructure yet. Here, a new setup is demonstrated, based on the JUNGFRAU detector and Jungfraujoch data-acquisition system, that enables collection of kilohertz serial crystallography data at fourth-generation synchrotrons. More importantly, it is shown that this setup is capable of collecting multiple-time-point time-resolved protein dynamics at kilohertz rates, allowing the probing of microsecond to second dynamics at synchrotrons in a fraction of the time needed previously. A high-quality complete X-ray dataset was obtained within 1 min from lysozyme microcrystals, and the dynamics of the light-driven sodium-pump membrane protein KR2 with a time resolution of 1 ms could be demonstrated. To make the setup more accessible for researchers, downstream data handling and analysis will be automated to allow on-the-fly spot finding and indexing, as well as data processing.

21 August 2020 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
ASAnastasya Shilova
Anastasya Shilova
HLHugo Lebrette
Hugo Lebrette
OAOskar Aurelius
Oskar Aurelius
JNJie Nan
Jie Nan
MWMartin Welin
Martin Welin
UMUwe Mueller
Uwe Mueller
Over the last decade, serial crystallography, a method to collect complete diffraction datasets from a large number of microcrystals delivered and exposed to an X-ray beam in random orientations at room temperature, has been successfully implemented at X-ray free-electron lasers and synchrotron radiation facility beamlines. This development relies on a growing variety of sample presentation methods, including different fixed target supports, injection methods using gas-dynamic virtual-nozzle injectors and high-viscosity extrusion injectors, and acoustic levitation of droplets, each with unique requirements. In comparison with X-ray free-electron lasers, increased beam time availability makes synchrotron facilities very attractive to perform serial synchrotron X-ray crystallography (SSX) experiments. Within this work, the possibilities to perform SSX at BioMAX, the first macromolecular crystallography beamline at MAX IV Laboratory in Lund, Sweden, are described, together with case studies from the SSX user program: an implementation of a high-viscosity extrusion injector to perform room temperature serial crystallography at BioMAX using two solid supports – silicon nitride membranes (Silson, UK) and XtalTool (Jena Bioscience, Germany). Future perspectives for the dedicated serial crystallography beamline MicroMAX at MAX IV Laboratory, which will provide parallel and intense micrometre-sized X-ray beams, are discussed.

4 April 2025 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
AGAna Gonzalez
Ana Gonzalez
TKTobias Krojer
Tobias Krojer
JNJie Nan
Jie Nan
MBMonika Bjelčić
Monika Bjelčić
SASwati Aggarwal
Swati Aggarwal
MTMarjolein M. G. M. Thunnissen
Marjolein M. G. M. Thunnissen
The first multi-bend achromat based synchrotron MAX IV operates two protein crystallography beamlines, BioMAX and MicroMAX. BioMAX is designed as a versatile, stable, high-throughput beamline catering for most protein crystallography experiments. MicroMAX is a more ambitious beamline dedicated to serial crystallography including time-resolved experiments. Both beamlines exploit the special characteristics of fourth-generation beamlines provided by the 3 GeV ring of MAX IV. In addition, the fragment-based drug discovery platform, FragMAX, is hosted and, at the FemtoMAX beamline, protein diffraction experiments exploring ultrafast time resolution can be performed. A technical and operational overview of the different beamlines and the platform is given as well as an outlook for protein crystallography embedded in the wider possibilities that MAX IV offers to users in the life sciences.

1 November 2023 in Acta Crystallographica Section D Structural Biology
Verified
Journal Article
Open access
PDF file
MBMonika Bjelčić
Monika Bjelčić
KCKajsa G. V. Sigfridsson Clauss
Kajsa G. V. Sigfridsson Clauss
OAOskar Aurelius
Oskar Aurelius
MMMirko Milas
Mirko Milas
JNJie Nan
Jie Nan
TUThomas Ursby
Thomas Ursby
In recent years, the emergence of serial crystallography, initially pioneered at X-ray free-electron lasers (XFELs), has sparked a growing interest in collecting macromolecular crystallographic data at room temperature. Various fixed-target serial crystallography techniques have been developed, ranging from commercially available chips to in-house designs implemented at different synchrotron facilities. Nevertheless, there is currently no commercially available chip (known to the authors) specifically designed for the direct handling of oxygen-sensitive samples. This study presents a methodology employing silicon nitride chips arranged in a `sandwich' configuration, enabling reliable room-temperature data collection from oxygen-sensitive samples. The method involves the utilization of a custom-made 3D-printed assembling tool and a MX sample holder. To validate the effectiveness of the proposed method, deoxyhemoglobin and methemoglobin samples were investigated using the BioMAX X-ray macromolecular crystallography beamline, the Balder X-ray absorption spectroscopy beamline and UV–Vis absorption spectroscopy.

29 May 2024 in Acta Crystallographica Section F Structural Biology Communications
Verified
Journal Article
Open access
PDF file
MBMonika Bjelčić
Monika Bjelčić
OAOskar Aurelius
Oskar Aurelius
JNJie Nan
Jie Nan
RNRichard Neutze
Richard Neutze
TUThomas Ursby
Thomas Ursby
Ribulose-1,5-bisphosphate carboxylase/oxygenase (RuBisCO) is the enzyme responsible for the first step of carbon dioxide (CO 2 ) fixation in plants, which proceeds via the carboxylation of ribulose 1,5-biphosphate. Because of the enormous importance of this reaction in agriculture and the environment, there is considerable interest in the mechanism of fixation of CO 2 by RuBisCO. Here, a serial synchrotron crystallography structure of spinach RuBisCO is reported at 2.3 Å resolution. This structure is consistent with earlier single-crystal X-ray structures of this enzyme and the results are a good starting point for a further push towards time-resolved serial synchrotron crystallography in order to better understand the mechanism of the reaction.