Qiong Li

Qiong Li

Auto-generated profile, based on publicly available information

Qiong Li

Department of Ophthalmology, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, Fuzhou, People’s Republic of China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2024 in Experimental Neurology
Verified
Journal Article
Closed access
XSXiao Su
Xiao Su
QLQiong Li
Qiong Li
MYMingzhi Yang
Mingzhi Yang
WZWenhui Zhang
Wenhui Zhang
XLXiaoxue Liu
Xiaoxue Liu
HHHui Huang
Hui Huang

30 December 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YFYabo Fu
Yabo Fu
YHYulong Huang
Yulong Huang
XLXiaobao Liu
Xiaobao Liu
CKChishan Kang
Chishan Kang
WWWenjie Wu
Wenjie Wu
QLQiong Li
Qiong Li
More attention should be paid to the deviations between the actual diameter of the rhexis reference circle which projected by the Image-guided systems and its intended size, and assess the influence of ocular biometric parameters on the deviation. In this study, the Callisto eye image-guided system was employed to generate a digital rhexis reference circle (rhexis overlay) set at an intended diameter of 6 mm and a screenshot of the video was taken at the end of the cataract surgery, then to compare the deviation between the observed rhexis overlay diameter (ROD) and the optic diameter (6 mm). The factors influencing diameter deviation were identified with univariate and multivariate linear regression. Subgroup analyses were conducted based on factors identified in the multivariate regression. And we observed that a total of 213 eyes of 174 patients were included in the final analysis. The diameter deviation averaged − 0.24 ± 0.28 mm (P = 0.0001) and was positively correlated with phakic anterior chamber depth (ACD) (P < 0.001) and negatively correlated with white-to-white (WTW) measurement (P < 0.001). Subgroup analyses revealed significantly greater diameter deviation in cases with preoperative ACD < 2.5 mm and WTW ≥ 12.0 mm (all P < 0.05). Following optimization, the mean diameter deviation was 0.00047 ± 0.26 mm (P > 0.05). In conclusion, the Callisto eye image-guided system demonstrates good precision in CCC assistance. However, there remains a slight deviation from the intended size when generating the rhexis reference circle in eyes with shallow anterior chambers and larger corneas. Implementing an optimization process could be beneficial for these eyes.

22 March 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
XLXiaobao Liu
Xiaobao Liu
WWWenjie Wu
Wenjie Wu
YHYulong Huang
Yulong Huang
YFYabo Fu
Yabo Fu
YHYue Huang
Yue Huang
QLQiong Li
Qiong Li
Purpose: This study aimed to assess the repeatability of intraocular lens (IOL) decentration measurements obtained through Pentacam, based on corneal topographic axis (CTA) and pupillary axis (PA), and to evaluate the level of agreement between Pentacam and OPD-Scan III devices in measuring IOL decentration. Methods: In this prospective observational case series, three measurements were performed with Pentacam to evaluate the repeatability of the measurements. The analysis included the calculation of the mean and standard deviations (SD), conducting a repeated measures analysis of variance (rANOVA), and determining an intraclass correlation coefficient (ICC) to assess the repeatability of the measurements. Moreover, Bland-Altman analysis was employed to assess the agreement between Pentacam and OPD-Scan III devices in measuring IOL decentration. IOL decentration measurements were obtained with respect to both CTA and PA. Results: A total of 40 eyes from 40 patients were analyzed. The rANOVA revealed no significant difference among three consecutive measurements of IOL decentration obtained with Pentacam. The mean SD of all parameters ranged from 0.04 mm to 0.07 mm. With CTA as the reference axis, the ICC values for Pentacam measurements of IOL decentration were 0.82 mm for the X-axis, 0.76 mm for the Y-axis, and 0.82 mm for spatial distance. When using PA as the reference axis, the corresponding ICC values were 0.87, 0.89, and 0.77, respectively. The 95% limits of agreement for all IOL decentration measurements were wide when comparing Pentacam and OPD-Scan III. Conclusions: Pentacam demonstrated high repeatability in measuring IOL decentration with respect to both CTA and PA. However, due to poor agreement between Pentacam and OPD-Scan III measurements, caution should be exercised when using data interchangeably between the two devices.

11 October 2023 in Austin Journal of Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
HZHuiying Zhang
Huiying Zhang
LJLing Jiang
Ling Jiang
QLQiong Li
Qiong Li
Conjunctival autograft was now the best method in pterygium operation. An absorbable suture with slipknot was used to fix the grafts of pterygium. A week after the surgery, most of the stitches had disintegrated and fallen out. This easy technique reduces the postoperative pain and the conjunctival reaction in the early postoperative period. It enables the surgeon to eliminate the need for postoperative suture removal, and relieve the patient’s anxiety of removing stitches during the review.

7 April 2022 in Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi = Chinese Journal of Otorhinolaryngology Head and Neck Surgery
Verified
Journal Article
Closed access
XZX C Zhu
X C Zhu
QLQ Li
Q Li
XSXiaofei Shen
Xiaofei Shen