29 August 2014 in IEEE Transactions on Power Electronics
Silicon-Carbide (SiC) MOSFETs, due to material properties, are designed with smaller thickness in the gate oxide and a higher electric field compared to Si MOSFETs. Consequently, the SiC MOSFETs have a worse reliability which causes higher leakage currents during instantaneous abnormal operating conditions. This paper investigates the reliability issues of the SiC MOSFET gate oxide under standard short-circuit test conditions. In this paper, 1200-V SiC MOSFETs are newly modeled, and also their short-circuit sustainability (tolerance) have been studied at different drain-source and gate-source voltages. A hardware tester circuit was designed and developed to test the devices under such extreme circuit conditions. Then, the gate reliability of SiC MOSFET devices have been compared to that of Si power devices of similar ratings. The results reveal a higher reduction in the instantaneous gate-source voltage of SiC MOSFETs compared to that of Si devices under the same operating conditions. The gate-voltage reduction phenomenon results from the higher leakage currents through the gate. Furthermore, it was found that the gate-source voltage reduction during the test depends on the gate structures. The gate voltage reduction of SiC MOSFETs with planar gate is higher than that of MOSFETs with shield planar gate. As the pulse duration increases in short-circuit tests, the leakage current in the gate-source of SiC devices increases. The results show that even though the SiC MOSFETs are very capable of processing long pulses and high power in the drain-source, the gate-source side is highly degraded by these pulses in the test. Moreover, whenever a small number of the short-circuit tests are applied, the gate structure of SiC MOSFETs becomes broken while the drain-source is still able to block the dc-link voltage. The paper concludes that the short-circuit reliability of the gate was found to be worse compared with commercial Si devices with similar rating.
14 June 2013 in IEEE Transactions on Energy Conversion
This paper presents a fast maximum power point tracking (MPPT) control algorithm for the photovoltaic (PV) in a hybrid wind-PV system, in which the PV generatormay also need to work in a reduced power mode (RPM) to avoid dynamic overloading. The two control modes, MPPT and RPM, are inherently compatible and can be readily implemented, without the need of a dumping load for the RPM. Following the establishment of a dynamic system model, the study develops the guidelines to determine the variables of a direct hill-climbing method for MPPT: the perturbation time intervals and the magnitudes of the applied perturbations. These results are then used to optimally set up a variable-step size incremental conductance (VSIC) algorithm along with adaptive RPM control. The power tracking performance and power limiting capability are verified by simulation and experiment.
22 May 2015 in IEEE Transactions on Energy Conversion
A standalone photovoltaic (PV) system with energy storage requires a complex control architecture to take into account the various operating modes. In many cases, a supervisory controller is necessary to manage the change of the control architecture according to the applied mode. This paper presents a flexible architecture of a PV power conditioning system with energy storage. The proposed conditioning unit contains a boost converter (BC), a single-phase inverter, and a bidirectional dc/dc converter connected to the PV side of the BC. The BC regulates the dc-link bus-voltage. The bidirectional dc/dc converter endures battery bank charge/discharge control and PV maximum power point tracking (MPPT). Such architecture guarantees nonchange in controller configuration when the storage disconnects. Therefore, the previously needed supervisory controller is eliminated. A system control strategy based on sliding-mode control (SMC) ensures a reliable output voltage regulation such as fast dynamic response, small steady-state error, and low total harmonic distortion (THD) under step changes and nonlinear loads. The controller structure, the dynamic behavior, and the design procedures are introduced. Finally, the validity of the proposed module with control strategy is verified through hardware experiments on a 500-W prototype test bed with a single TMS320F28335 DSP module.
4 October 2018 in IEEE Transactions on Energy Conversion
MMMohana Sundar Manoharan
An isolated single sourced multi-output dc/dc converter with a high-frequency link was proposed before to feed different cells of the Asymmetrical Cascaded H-bridge inverter. One of the ACHB fundamental advantages is that the main H-bridge is commutated with fundamental frequency, passing the majority of the inverter power. However, the isolated DC/DC converter needs to be connected to the main voltage source with high-voltage/high-frequency switches, which limits the power capability and the efficiency. In this paper, a switching pattern based on nearest level modulation method is proposed to command all the power to be transferred through the main H-bridge. Therefore, the power circulates between the auxiliary H-bridges with no need for high voltage switches. As a result, the auxiliary converter is needed with only 5% of the power rating. This solution improves cost, size, and the efficiency. Furthermore, the architecture makes the inverter more suitable for high power, high voltage applications. The inverter switching strategy is based on programmable firing angles. The grid connected inverter main dc-link is controlled to achieve maximum power point tracking, while the isolated converter is controlled to regulate the auxiliary DC-links. The proposed topology was verified by simulation and experimental results through around 1.5-kW hardware prototype.
24 November 2016 in IEEE Transactions on Power Electronics
MMMohana Sundar Manoharan
A power conditioning system (PCS) using multiple module-integrated converters and a single sourced 27-level asymmetric cascaded H-bridge multilevel inverter (MLI) without regeneration for photovoltaic (PV) applications is proposed. A newly suggested hybrid-switching closed-loop strategy is proposed to enable the use of a 27-level inverter in PV systems. The suggested hybrid-switching strategy implements fundamental line-frequency switching in the main H-bridge to ensure a high efficiency and low leakage current operation. Furthermore, high-frequency switching is used in the auxiliary H-bridge cells to achieve a higher bandwidth control loop. A cost-effective unidirectional single-ended 1-kW dc-dc module based on a boost coupled inductor and charge-pump circuits is proposed to achieve a single PV source per module for a multistring configuration. To couple the unidirectional converters with the central inverter, a jumping element in the hybrid switching strategy is introduced to enable an optimal nonregenerative operation. The proposed PCS with the control scheme is analyzed and verified using hardware results in a grid connected mode of operation.
8 April 2010 in IEEE Transactions on Energy Conversion
This paper presents a constant power soft-stall control scheme for a vertical-axis wind turbine (VAWT) fitted with a permanent magnet generator. Small-scale VAWTs are attractive due to their ability to capture wind from different directions without using yaw; this simplifies the design and gives the turbine tolerance to turbulence in urban areas. One difficulty with VAWTs is to prevent overspeeding and component overloading at excessive wind velocities. This paper suggests that necessary control can be achieved by controlling the electric power in order to operate the turbine in the stall region. This control strategy attenuates the stress in the system, while smoothing the power generated. It is shown that the controller can stabilize the nonlinear system using an adaptive current feedback loop. The controller does not need wind velocity or turbine speed, but is based on the current and voltage measured on the dc side of the rectifier connected to the permanent magnet synchronous generator. Maximum power point tracking (MPPT) control is provided in normal operation. Simulation and experimental results are presented.