Chengcheng Yao

Chengcheng Yao

Auto-generated profile, based on publicly available information

Chengcheng Yao

Center for High Performance Power Electronics, The Ohio State University, Columbus, OH, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018
Verified
Conference Paper
Closed access
YZYue Zhang
Yue Zhang
GYGe Yang
Ge Yang
XHXiaoteng He
Xiaoteng He
MEMohamed Elshaer
Mohamed Elshaer
WPWilliam Perdikakis
William Perdikakis
CCChingchi Chen
Chingchi Chen
Electric vehicle (EV) chargers are traditionally isolated from the grid. Non-isolated chargers have great potential as they enable higher power density at lower cost. Integrated chargers have the potential to utilize existing onboard, high power-rated electronic components for Level 3 charging. Four possible non-isolated integrated charger topologies based on permanent magnet synchronous machine (PMSM) are introduced at the beginning of this paper. Then, the issue of common mode (CM) leakage current through the on-board filters is identified and analyzed. It is found that the leakage current could rise to dangerous levels and cause potential electric shocks to users. The negative influence and safety risks from the leakage current for different grounding systems are also discussed. Experimental results are presented to validate the leakage current analysis. Finally, possible mitigation techniques of the leakage current are discussed.

2 February 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
CYChengcheng Yao
Chengcheng Yao
ZWZhongjing Wang
Zhongjing Wang
WLWenwei Li
Wenwei Li
HLHe Li
He Li
JQJinziyang Qian
Jinziyang Qian
JWJin Wang
Jin Wang
This paper investigates the power module design for better common-mode (CM) noise and thermal performance. A high-frequency full-bridge diode rectifier is selected as a case study. The most influential factors in CM noise generation and mitigation are first identified with a simplified CM equivalent model and a comprehensive parametric study. Studies show proper parasitic value and parasitics symmetry can improve CM noise performance. The analysis of packaging structures indicates the vertical module has better CM noise and thermal performance than the traditional lateral wire-bonded module. To validate this, both modules are designed and prototyped for verification. The thermal simulation shows the vertical module exhibits a 25.5% lower thermal resistance from junction to case and a 51% increase of power density in a force-air-cooled condition. Experiments also reveal 15 dB of CM noise reduction from 150 kHz to 6 MHz and a 32 % improvement of power density in a force-air-cooling condition. Finally, a case study demonstrates the vertical power module CM noise performance in a typical unsymmetrical topology. This results in a 30 dB CM noise reduction up to 6 MHz.

11 April 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
CYChengcheng Yao
Chengcheng Yao
XZXuan Zhang
Xuan Zhang
YZYue Zhang
Yue Zhang
PYPengzhi Yang
Pengzhi Yang
HLHe Li
He Li
JWJin Wang
Jin Wang
This paper presents a comprehensive analysis of the generation mechanism and suppression methods of common-mode (CM) touch current when employing semiconductor-based galvanic isolation (SGI). SGI achieves galvanic isolation by utilizing semiconductor switches to deliver differential-mode (DM) power during their on states while sustaining CM isolation voltage during their off states. In SGI converters, the touch current (TC) is generated as the switch output capacitance is charged by the CM voltage during each turn-on transient. The TC rises as the switching frequency increases, which limits the system power density. This process is modeled by the proposed high-frequency pulse current model and the low-frequency equivalent resistance-based average model. Passive TC suppression approaches are reviewed, and an active TC compensation method has been proposed. A 2-kW EV battery charger with a GaN-based Totem-pole power factor correction stage and an SGI-based dc/dc stage has been built and tested. The touch current has been effectively reduced by 27 dB. It allows the converter to operate at a higher switching frequency to achieve higher power density while meeting the safety standards' touch current requirement.

18 October 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
YZYue Zhang
Yue Zhang
CYChengcheng Yao
Chengcheng Yao
XZXuan Zhang
Xuan Zhang
HCHuanyu Chen
Huanyu Chen
HLHe Li
He Li
JWJin Wang
Jin Wang

7 April 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
CYChengcheng Yao
Chengcheng Yao
PYPengzhi Yang
Pengzhi Yang
HCHuanyu Chen
Huanyu Chen
MLMingzhi Leng
Mingzhi Leng
HLHe Li
He Li
JWJin Wang
Jin Wang
Real-time junction temperature measurements can be very beneficial for improving power converter's design, performance, and reliability. Junction temperature sensing using an on-die diode sensor is a promising solution. However, a strong low-pass filter is usually applied to filter out the sensor's noise during switching transients, which reduces the sensor's bandwidth. This paper aims to improve the sensing system's bandwidth to achieve an ultrafast real-time junction temperature measurement. Three noise coupling mechanisms have been identified and verified by both simulations and experiments. The noise coupling model-based crosstalk capacitances estimation method is proposed and validated. Noise mitigation methods are proposed, thus only a 200-kHz low-pass filter is needed for the noise suppression purpose, which is a significant improvement from the current field implementation of tens of hertz bandwidth.