20 March 2023 in IEEE Transactions on Applied Superconductivity
The superconducting cable for an electric propulsion system of an airplane was developed using coated conductors (CCs). To lighten the cable-weight, stacked conductors without the center core were employed, leading to the reduction of the diameter and effectively reducing the weight. The cable demonstrated reasonable high Ic values for the DC current. Additionally, the cable was revised for loading the AC current. Gaps in the insulators of the craft-papers and spacers were added to separate each phase-conductor. Evaluation of the AC current loading confirmed no degradation at loads greater than 1900 Arms, which is sufficient for a 1 MW propulsion system. A low unit weight of 1.44 kg/kA/m of the cable was achieved. Considering the future goal of a 20 MW system, the performance of the coated conductors was developed to improve the infield values. The long CCs were successfully fabricated by the UTOC-MOD process, which is effective for refining the pinning centers. The pseudo-FFDS cable was confirmed to achieve a high Ic value of 304 A/cm-w at 70 K under 2.5 T. Finally, a light unit weight of 0.35 kg/kA/m for the future cable concept was proposed from the weight analysis.
11 March 2021 in IEEE Transactions on Applied Superconductivity
A large-scale demonstration test of a triaxial high-temperature superconducting (HTS) cable for a practical cable system was performed in a chemical plant of a private company. The 200 m-long HTS (REBCO: REBa 2 Cu 3 O 7-δ ) triaxial cable, which was manufactured by connecting 3 cables using 2 joints via a snake-shaped layout, was laid approximately 5 m higher than ground level, and the cable was cryocooled by circulating liquid nitrogen. For the preverification test, the rise-up test of the liquid nitrogen and the development of technology for bending the cable, joining it, as well as laying and installing it, were conducted. No leakage of liquid nitrogen at the terminal due to damage caused by heat shock or liquid nitrogen drop impact was observed. The pressure required for the liquid nitrogen to achieve a 5 m height was from 27.5 to 33 kPa, which is in good agreement with the calculated pressure of 33.6 kPa. The cooling rate was well controlled, and the desired level of 4 K/h was achieved. The economic challenges and methods of achieving market penetration were also discussed. The goal was to realize a superconducting cable for practical applications, and it was thought that the energy and costs necessary for cryocooling could be drastically reduced by using the existing cold system in the plant. In this way, it is expected HTS cables can achieve low costs and high energy-saving effects and penetrate markets in the future.
25 January 2018 in IEEE Transactions on Applied Superconductivity
For the power line between a power generator and a step-up transformer, Isolated Power Bus (IPB) is generally used. The present IPB has a normal cylindrical conductor made of aluminum or copper at the center of the outer jacket and generates very huge Joule loss. To decrease it, superconducting buses have been developing. In this study, a 22 kV-3 kA triaxial superconducting bus was designed and fabricated with YBa2Cu3O7-d (YBCO) tapes and the various kinds of properties were investigated. Previously the AC and lightning impulse withstand voltage test, critical current (Ic) test, and AC loss measurement were conducted and it was shown that the developed triaxial superconducting cable met the designed specifications. In this paper, a sudden short-circuit test of a 2 m-long triaxial cable was carried out by using a 200 MVA short circuit generator. For protection, each phase of the cable was connected to a XLPE cable with a length of 3 m and a cross-sectional area of 250 mm2 in parallel. Three-phase short circuit current of 25 kA was applied to every phase of the cable bathcooled with liquid nitrogen at 77 K for 2 seconds. As a result, the following tremendous phenomenon was demonstrated. Any phase of the triaxial cable kept a flux-flow state and did not quench. Short circuit current was shared between the superconducting cable and the connected XLPE cable, and the branch current ratio varied even during one period of 60 Hz. The numerical simulation was also conducted to explain the phenomenon theoretically. That should contribute to the instantaneous recovery to a normal operation after a short-period interrupt of the circuit
9 February 2023 in IEEE Transactions on Applied Superconductivity
A triaxial high-temperature superconducting (HTS) cable for practical cable systems was installed in the chemical plant of a private company (BASF Japan), and a large-scale demonstration test was performed. An HTS (REBa 2 Cu 3 O 7-δ ) triaxial cable with a length of 200 m was used, and it was laid at a height of approximately 6 m above the ground and cooled using circulating liquid nitrogen. The test was performed from November 2020 to September 2021. In this paper, we report the results of the demonstration test and the energy-saving effects of the cable system.
14 February 2017 in IEEE Transactions on Applied Superconductivity
When conventional power cables are replaced with superconducting ones, it is necessary to realize a large transmission capacity with a low heat-road from an economic standpoint. In this regard, the isolation power bus (IPB), which is used to connect a generator to a step-up transformer in power plants, is one of the potential candidates to achieve this. We have been developing a 22 kV class triaxial superconducting bus as an alternative to the IPB in which Y1Ba2Cu3O7-d (YBCO) tapes are used, and we have already reported a basic design [1]. In this study, we fabricated 22 kV-3 kA class test cables and terminations to verify the design and investigate the properties of the system. A 7-m-long superconducting test cable was manufactured by using industrial winding machines and critical current Ic values, and voltage withstand tests were performed. The Ic value of each phase was 4 kA or more at 77 K, which was almost equal to the value of the design. In addition, the withstand voltage was higher than the AC withstand voltage of 50 kV and the lightning impulse of 125 kV. Further, thermal loss to the cryogenic region from the cable and terminations was calculated, and the flow pattern and the pressure loss of liquid nitrogen in a 100-m-long cable were simulated by using FLUENT simulation software. The cryogenic system could be designed based on the simulation. The termination design was the most difficult because heat insulation and dielectric insulation for a high voltage had to be realized. We tested various kinds of heat insulation techniques with several vacuum levels to develop an appropriate design.