Jussiane Souza Silva

Jussiane Souza Silva

Auto-generated profile, based on publicly available information

Jussiane Souza Silva

Federal University of Santa Maria

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2017 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
CBCezar Augusto Bizzi
Cezar Augusto Bizzi
MPM. F. Pedrotti
M. F. Pedrotti
JSJ. S. Silva
J. S. Silva
JBJ. S. Barin
J. S. Barin
JNJ. A. Nóbrega
J. A. Nóbrega
Erico Marlon Moraes FloresErico Marlon Moraes Flores
Erico Marlon Moraes Flores
In recent years, the evolution of instrumental techniques such as inductively coupled plasma (ICP)-based techniques has allowed multielemental analytical capability at trace levels and for a variety of matrices. Such information can be strongly affected by matrix-related effects causing spectral and non-spectral interferences and several alternatives have been proposed to overcome these drawbacks. Sample preparation methods with high digestion efficiency have been the most convenient for subsequent ICP analysis. Conventionally, high digestion efficiency can be obtained following protocols based on the addition of a relatively high amount of concentrated reagents combined with operational conditions using high temperature and pressure. Modern instrumentation and a better understanding of chemical reactions related to sample digestion have enabled the achievement of high digestion efficiency even using dilute reagents. In this sense, this review presents the main advances for the digestion of organic samples, based on the reduction of reagents without impairing digestion efficiency for further multielement determination by ICP-based techniques. Recent approaches are highlighted, such as the use of dilute acid solutions with the aid of O2, H2O2 and UV-assisted digestion, high pressure flow digestion, and combustion methods, all assisted by microwave radiation. The main features and applications reported in the past ten years are also covered. Finally, a critical view of the suitability of metrics for the evaluation of greener digestion methods, mainly for matrices considered hard to be digested using conventional protocols, is presented.

22 November 2013 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
CBCezar Augusto Bizzi
Cezar Augusto Bizzi
EFEder L. M. Flores
Eder L. M. Flores
JNJoaquim A. Nóbrega
Joaquim A. Nóbrega
JOJussiane S. S. Oliveira
Jussiane S. S. Oliveira
Lucas SchmidtLucas Schmidt
Lucas Schmidt
SMSérgio R. Mortari
Sérgio R. Mortari
Many efforts have been made in order to reduce the amount of reagents and waste produced in analytical laboratories. However, suitable digestion efficiency must be considered, and depending on the sample preparation procedure, incomplete digestion can result in severe matrix effects during analysis by spectrometric techniques such as ICP OES and ICP-MS. In the present work a procedure based on the use of H2O2 was developed in order to minimize the consumption of HNO3 without decreasing the efficiency of digestion. Although H2O2 has been used combined with HNO3 for sample digestion, its role is still not completely elucidated even as its action combined with O2 in pressurized systems. The performance obtained using H2O2 was similar to that observed when adding O2 to the reaction vessel, driving the better understanding of the role of H2O2 in closed digestion procedures. Digestion using H2O2 allowed the use of HNO3 solutions as diluted as 1 mol L−1 to digest sample masses of biological materials as high as 500 mg. The proposed procedure allowed a reduction of up to 14 and 9.3-fold in the HNO3 amount normally used in whole milk powder and bovine liver digestions, respectively, without decreasing the digestion efficiency. Calcium, Cu, Fe, K, Mg, Mn, Mo, Na, and Zn were determined by ICP OES, while Cd, Co, and Pb were determined by ICP-MS. Using diluted HNO3 solution low blank values were obtained resulting in relatively lower limits of detection and relative standard deviations. The accuracy was evaluated by using certified reference materials of milk powder and bovine liver (agreement was better than 95% to certified values for all evaluated analytes).


1 May 2018 in Ecotoxicology and Environmental Safety
Verified
Journal Article
Closed access
RCRafael da Rosa Couto
Rafael da Rosa Couto
JFJéssica Faversani
Jéssica Faversani
CCCARLOS ALBERTO Alberto CERETTA
CARLOS ALBERTO Alberto CERETTA
PFPaulo Ademar Avelar Ferreira
Paulo Ademar Avelar Ferreira
CMCarina Marchezan
Carina Marchezan
Gustavo BrunettoGustavo Brunetto
Gustavo Brunetto

1 November 2015 in Talanta
Verified
Journal Article
Closed access
JOJussiane S.S. Oliveira
Jussiane S.S. Oliveira
RPRochele Sogari Picoloto
Rochele Sogari Picoloto
CBCezar Augusto Bizzi
Cezar Augusto Bizzi
Paola A. MelloPaola A. Mello
Paola A. Mello
JBJuliano S. Barin
Juliano S. Barin
Erico Marlon Moraes FloresErico Marlon Moraes Flores
Erico Marlon Moraes Flores

1 July 2014 in Analytica Chimica Acta
Verified
Journal Article
Closed access
CBCezar Augusto Bizzi
Cezar Augusto Bizzi
JNJoaquim A. Nóbrega
Joaquim A. Nóbrega
JBJuliano S. Barin
Juliano S. Barin
JOJussiane S.S. Oliveira
Jussiane S.S. Oliveira
Lucas SchmidtLucas Schmidt
Lucas Schmidt
Erico Marlon Moraes FloresErico Marlon Moraes Flores
Erico Marlon Moraes Flores