Magnetic sensor array is usually designed for object detection and localization, where sensor coordinate is required to be consistent. Misalignment angles between coordinates should be calculated and calibrated. A new calibration method is proposed in order to calibrate the misalignment error between host frame and sensors. Host platform frame and perpendicular platform are used to obtain misalignment angles of sensor array. Experiment results shows that it can estimate all angles of magnetic sensors and suppress misalignment error. Misalignment RMS error is a reduction from 1109.7 nT with 27.6 nT, which means 2.48% indeed, thus improving the remote sensing accuracy of array which is unified to host frame coordinate.
Magnetic field measurement is an important analysis method in mining industry. Magnetic distortion of inertial navigation system (INS) is one severe error of portable geomagnetic field vector measurement instrument. A correlation algorithm is proposed for component compensation, in which magnetometer attitude information is provided by INS, and the geomagnetic field vector without magnetic anomaly is measured. Experiment result shows that distortion field vector of INS can reach hundreds of nT, which are suppressed to about 4.8 % after compensation, thus it is effective for component compensation. The magnetic anomaly measurement using magnetic intensity test (TMI) method and the proposed instrument are analyzed. In application, the proposed compensation way shows effectiveness comparing with several traditional compensation methods. In addition, the potential applications in mining industry are discussed.