Hongfeng Pang

Dr. Hongfeng Pang


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CWChengbiao Wan
Chengbiao Wan
HPHongfeng Pang
Hongfeng Pang
SMShaofeng Mou
Shaofeng Mou
HLHeng Li
Heng Li
MPMengchun Pan
Mengchun Pan
DYDaoning Yang
Daoning Yang
Magnetic anomaly detection (MAD) is a useful method for the detection of visually obscured ferromagnetic targets. However, when the prior information of the target signal is lacking or inaccurate, the performance of the traditional method based on orthonormal basis functions may degrade rapidly. Therefore, a novel detection method based on a parallel stochastic resonance (PSR) system is proposed, which is named the PSR detector. This method uses a PSR system to improve the signal-to-noise ratio (SNR) and then reveals anomaly signals by energy detector. Experimental results show that the detection probability of PSR detector reaches 70% even if input SNR is −3 dB and approximated to 100% if SNR is 0 dB under the false alarm probability (FAR) of 5%. In particular, the PSR detector provides a higher detection probability than the minimum entropy (ME) detector and a more balanced performance than the detector using a single stochastic resonance (SSR) system when the deterministic parameter of the target signal is lacking.

1 August 2017 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
PDF file
CWChengbiao Wan
Chengbiao Wan
MPMengchun Pan
Mengchun Pan
QZQi Zhang
Qi Zhang
DCDixiang Chen
Dixiang Chen
HPHongfeng Pang
Hongfeng Pang
XZXuejun Zhu
Xuejun Zhu
In this work, the authors improve the magnetic anomaly detector by using Karhunen–Loeve expansion, for expanding the detection distance of visually obscured ferromagnetic object when the target signal is contaminated by coloured noise. In the detector, the orthonormal basis functions are modified by the autocorrelation function of geomagnetic noise, and the anomaly is detected by matched filtering. Compared with the traditional detector, simulation results show that the modified detector has better performance with coloured Gaussian noise; especially, the improvement is more evident when the noise exponent is bigger. The real geomagnetic noise is proved to be coloured and obey approximate Gaussian distribution by the measurements in experiment. Tests with this noise indicate that the proposed detector achieves an incremental detection probability of 0.1 – 0.2 in the case of low signal‐to‐noise ratio, which makes it more attractive in practice.

9 April 2014 in IEEJ Transactions on Electrical and Electronic Engineering
Verified
Journal Article
Closed access
PDF file
HPHongfeng Pang
Hongfeng Pang
DCDixiang Chen
Dixiang Chen
MPMengchun Pan
Mengchun Pan
SLShitu Luo
Shitu Luo
QZQi Zhang
Qi Zhang
FLFeilu Luo
Feilu Luo

27 July 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HPHongfeng Pang
Hongfeng Pang
MPMengchun Pan
Mengchun Pan
WQWei Qu
Wei Qu
LQLei Qiu
Lei Qiu
JYJun Yang
Jun Yang
XZXuejun Zhu
Xuejun Zhu
Magnetic sensor array is usually designed for object detection and localization, where sensor coordinate is required to be consistent. Misalignment angles between coordinates should be calculated and calibrated. A new calibration method is proposed in order to calibrate the misalignment error between host frame and sensors. Host platform frame and perpendicular platform are used to obtain misalignment angles of sensor array. Experiment results shows that it can estimate all angles of magnetic sensors and suppress misalignment error. Misalignment RMS error is a reduction from 1109.7 nT with 27.6 nT, which means 2.48% indeed, thus improving the remote sensing accuracy of array which is unified to host frame coordinate.

29 April 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HPHongfeng Pang
Hongfeng Pang
CWChengbiao Wan
Chengbiao Wan
SMShaofeng Mou
Shaofeng Mou
LWLu Wei
Lu Wei
HLHeng Li
Heng Li
DYDaoning Yang
Daoning Yang
Strap-down geomagnetic vector measurement system usually consists of three-axis magnetometer and inertial units, which is an effective device for measuring geomagnetic vector. However, its measurement accuracy is limited by disturbance of ferromagnetic material, measurement error of magnetometer and error caused by misalignment. Therefore, an integrated calibration method for strap-down geomagnetic vector measurement system is proposed. Firstly, the integrated error model is established, and a system with linear equations constraint is constructed by the measurements of inertial units, three-axis magnetometer and proton magnetometer; secondly, calibration parameters can be estimated by two-step least squares estimation (LSE); finally, geomagnetic vector measurement can be calibrated with these parameters in real time. Simulation results show that the relative errors between estimation and true parameters are less than 3%. Experimental results demonstrate that the errors of strap-down geomagnetic vector measurement system are suppressed effectively after integrated calibration, where North, Vertical and East component measurement errors are reduced from 809.2 nT, 300.0 nT, 776.8 nT to 14.8 nT (1.83% of uncalibrated value), 11.9 nT (3.97%), 32.5 nT (4.18%) respectively, and measurement accuracy of declination and inclination are achieved to 0.1°. Furthermore, the calibration error and time are least compared with traditional methods.

6 March 2023 in Wireless Networks
Verified
Journal Article
Closed access
PDF file
BXBo Xiao
Bo Xiao
WQWei Qu
Wei Qu
LQLei Qiu
Lei Qiu
HPHongfeng Pang
Hongfeng Pang
GYGang Yao
Gang Yao