State Key Laboratory of High Density Electrical Energy Conversion, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
Auto-generated profile, based on publicly available information
Xinzheng Shan
State Key Laboratory of High Density Electrical Energy Conversion, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
In deadbeat predictive current control scheme, the input-delay arising from the signal conditioning circuit (SCC) in current measurement will lead to predictive error and control performance deterioration. In this letter, first, the input-delay issue is detailly analyzed. Then, to solve it, the input-delay is identified by the use of frequency characteristic of SCC. On this basis, a novel phase-shift sampling method is put forward to substantially compensate for the input-delay. When adopting this strategy, current control performance can be significantly enhanced without any pattern judgments or complex calculations. Finally, experiments are performed to verify the effectiveness of the proposed strategy.