Lars Körner

Lars Körner

Auto-generated profile, based on publicly available information

Lars Körner

University of Nottingham NG8 1BB Nottingham United Kingdom

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2017 in Journal of Micro and Nano-Manufacturing
Verified
Journal Article
Closed access
PDF file
VNVahid Nasrollahi
Vahid Nasrollahi
Pavel PenchevPavel Penchev
Pavel Penchev
SDStefan Dimov
Stefan Dimov
LKLars Korner
Lars Korner
Richard LeachRichard Leach
Richard Leach
KKKyunghan Kim
Kyunghan Kim
Laser microprocessing is a very attractive option for a growing number of industrial applications due to its intrinsic characteristics, such as high flexibility and process control and also capabilities for noncontact processing of a wide range of materials. However, there are some constrains that limit the applications of this technology, i.e., taper angles on sidewalls, edge quality, geometrical accuracy, and achievable aspect ratios of produced structures. To address these process limitations, a new method for two-side laser processing is proposed in this research. The method is described with a special focus on key enabling technologies for achieving high accuracy and repeatability in two-side laser drilling. The pilot implementation of the proposed processing configuration and technologies is discussed together with an in situ, on-machine inspection procedure to verify the achievable positional and geometrical accuracy. It is demonstrated that alignment accuracy better than 10 μm is achievable using this pilot two-side laser processing platform. In addition, the morphology of holes with circular and square cross sections produced with one-side laser drilling and the proposed method was compared in regard to achievable aspect ratios and holes' dimensional and geometrical accuracy and thus to make conclusions about its capabilities.

26 September 2008 in Synchrotron Radiation News
Verified
Journal Article
Closed access
OBOliver Betz
Oliver Betz
ARA. Rack
A. Rack
CSC. Schmitt
C. Schmitt
AEA. Ershov
A. Ershov
ADA. Dieterich
A. Dieterich
TBTilo Baumbach
Tilo Baumbach

16 September 2019 in Measurement Science and Technology
Verified
Journal Article
Open access
LKLars Körner
Lars Körner
SLSimon Lawes
Simon Lawes
DBDavid Bate
David Bate
LNLewis Newton
Lewis Newton
NSNicola Senin
Nicola Senin
RLRichard Leach
Richard Leach
X-ray computed tomography (XCT) is a non-destructive imaging technique that has recently gained interest as a tool to measure surface topography. Large acquisition times are a major shortcoming of XCT. One contributing factor to the acquisition time is that a measurement can require the acquisition of thousands of radiographic projections. This paper explores the combined effects of undersampling, i.e. taking fewer radiographic projections and sinogram interpolation, i.e. estimating the missing radiographic projections by interpolation. Different degrees of sinogram interpolation are investigated through the measurement of the surfaces of a metal, additively manufactured part. The quality of the measurement result is assessed via the analysis of the reconstructed volumes, through the computation of quantitative indicators of spatial resolution and noise, and via the analysis of surface topographies extracted from the reconstructed volumes. The quality of the surfaces is assessed through the use of statistical models designed to estimate repeatability errors in the reconstruction, and through the computation of surface texture parameters. Results obtained with no undersampling and no sinogram interpolation are taken as reference. It is shown that noise in the volumetric reconstruction increases with respect to the reference with larger degrees of undersampling, but the increment can be partly compensated by sinogram interpolation with the effects on spatial resolution more difficult to interpret. The computation of surface texture parameters results in similar values for all but one case, the largest undersampling. The topography of the reconstructions indicate that the repeatability error remains similar in all experimental conditions, excluding the case of largest undersampling. Overall, the results indicate that a reduction of the acquisition time of XCT topography measurement is feasible. However, the obtained surface topographies suffer, and large undersampling creates unrecoverable negative effects on the spatial resolution, the noise characteristics and the obtained topographies, even when sinogram interpolation is used.

1 March 2019 in e-Journal of Nondestructive Testing
Verified
Journal Article
Open access
PDF file
LKLars Körner
Lars Körner
UNUniversity of Nottingham
University of Nottingham
SLSimon Lawes
Simon Lawes
LNLewis Newton
Lewis Newton
Nicola SeninNicola Senin
Nicola Senin
NLNikon Metrology Uk Ltd
Nikon Metrology Uk Ltd
The Largest Portal of Nondestructive Testing (NDT) Open Access Archive, Conference Proceedings, Journal Articles, News, Products, Services. Professional Networking, Exhibition, Forums, Jobs

1 September 2021 in Precision Engineering
Verified
Journal Article
Closed access
HVHerminso Villarraga-Gómez
Herminso Villarraga-Gómez
LKLars Körner
Lars Körner
Richard LeachRichard Leach
Richard Leach
Stuart SmithStuart Smith
Stuart Smith